User manual LG DK7788P
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG DK7788P. We hope that this LG DK7788P user guide will be useful to you.
Lastmanuals help download the user guide LG DK7788P.
Manual abstract: user guide LG DK7788P
Detailed instructions for use are in the User's Guide.
[. . . ] The reference piping consists of 5 m of main piping and 2. 5 m of branch piping connected with 0 meter height. [. . . ] The reference piping consists of 5 m of main piping and 2. 5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. 19. 0CWB 27CDB TC SHC
4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 4 4. 2 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 4 5. 3 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 6. 9 6. 7 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 8 2. 7 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 5 3. 4 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 5 4. 4
20. 0CWB 28CDB TC SHC
4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 5 4. 4 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 6 5. 4 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 1 6. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 8 2. 7 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 5 3. 4 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 5 4. 4
22. 0CWB 30CDB TC SHC
4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 7 4. 6 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 5. 9 5. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 5 7. 3 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 8 2. 7 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 5 3. 4 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 7 4. 5 4. 4
24. 0CWB 32CDB TC SHC
5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 0 4. 8 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 2 6. 0 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 7. 8 7. 6 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 7 2. 6 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 4 3. 3 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 4 4. 3
EN
7
Engineering Data
6
Wiring diagram
Model : MMK-AP0073H, AP0093H, AP0123H, AP0153H, AP0183H, AP0243H
8
EN
Engineering Data
7
Fan characteristics
Discharge Air Speed and Air Throw
High Wall Type (3 series) Model : MMK-AP0073H Horizontal discharge initial speed High wind : 3. 8m/s Med wind : 2. 9m/s Low wind : 2. 5m/s Model : DK7788P, AP0123H Horizontal discharge initial speed High wind : 4. 0m/s Med wind : 3. 2m/s Low wind : 2. 5m/s
5 4 3 2 1 0 0 1 2 3 4 5 6 7 Horizontal throw (m) High Med Low
Air speed (m/s)
4 3 2 1 0 0 1 2 3 4 5 6
High Med Low
7
Horizontal throw (m)
Model : MMK-AP0153H, AP0183H Horizontal discharge initial speed High wind : 5. 1m/s Med wind : 4. 2m/s Low wind : 3. 2m/s
6 5 4 3 2 1 0 0 1 2 3 4 5 6 Horizontal throw (m)
Model : MMK-AP0243H Horizontal discharge initial speed
Air speed (m/s)
5
High wind : 6. 2m/s Med wind : 4. 7m/s Low wind : 3. 7m/s
High Med Low
6 5 4 3 2 1 0 0 1 2 3 4 5 6 Horizontal throw (m)
Air speed (m/s)
Air speed (m/s)
High Med Low
7
7
EN
9
Engineering Data
8
Sound characteristics (NC Curve)
High Wall Type (3 series)
1m
1m Microphone
MMK-AP0073H
Sound pressure level (dB(A))
90 HH H 80 L
DK7788P/AP0123H
HH - H - L 35 - 31 - 28
90 HH 80 H L 70 Octave band sound pressure level (dB)
Sound pressure level (dB(A))
HH - H - L 37 - 32 - 28
70 Octave band sound pressure level (dB)
NC-70
NC-70
60 NC-60 50 NC-50 40 NC-40
60 NC-60 50 NC-50 40 NC-40
30 NC-30 20
30 NC-30 20
Approximate threshold of hearing for continuous noise
NC-20 10
Approximate threshold of hearing for continuous noise
NC-20
10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz)
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
MMK-AP0153H/AP0183H
Sound pressure level (dB(A))
90 HH 80 H L 70 Octave band sound pressure level (dB)
MMK-AP0243H
HH - H - L 41 - 36 - 33
90 HH 80 H L 70 Octave band sound pressure level (dB)
Sound pressure level (dB(A))
HH - H - L 46 - 39 - 34
NC-70
NC-70
60 NC-60 50 NC-50 40 NC-40
60 NC-60 50 NC-50 40 NC-40
30 NC-30 20
30 NC-30 20
Approximate threshold of hearing for continuous noise
NC-20 10
Approximate threshold of hearing for continuous noise
NC-20
10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz)
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
10
EN
Engineering Data
9
Accessories
Remote controller
Packed with the indoor unit
Name Model name Appearance Application · · · · · · · Function Start / Stop Changing mode Temperature setting Air flow changing (5 steps) Louver setting Clock Timer function - ON/OFF timer (10 min. step) - Everyday timer - Sleep timer - COMFORT SLEEP timer · High power mode · QUIET mode · One-touch pre-set memory
Wireless remote controller
Finished goods
Model Name Wired remote controller Simple remote controller Wireless remote controller kit ON-OFF controller Central remote controller Schedule Timer Remote controller with weekly timer RBC-AMT32E RBC-AS21E2 TCB-AX21E2 TCB-CC163TLE2 TCB-SC642TLE2 TCB-EXS21TLE RBC-AMS41E In weekly timer mode, RBC-AMT32E is necessary. Notes
EN
WH-L11SE
11
High-wall Type (3 series) Engineering Data Book
Feb. [. . . ] step) - Everyday timer - Sleep timer - COMFORT SLEEP timer · High power mode · QUIET mode · One-touch pre-set memory
Wireless remote controller
Finished goods
Model Name Wired remote controller Simple remote controller Wireless remote controller kit ON-OFF controller Central remote controller Schedule Timer Remote controller with weekly timer RBC-AMT32E RBC-AS21E2 TCB-AX21E2 TCB-CC163TLE2 TCB-SC642TLE2 TCB-EXS21TLE RBC-AMS41E In weekly timer mode, RBC-AMT32E is necessary. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG DK7788P Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG DK7788P will begin.