Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG F-261A. We hope that this LG F-261A user guide will be useful to you.
Lastmanuals help download the user guide LG F-261A.
Detailed instructions for use are in the User's Guide.
[. . . ] Metric/Imperial pipe conversion:
Note 2:
Note 3: Note 4:
Diameter (mm) Nominal Diameter (inch)
6. 4 1/4
9. 5 3/8
12. 7 1/2
15. 9 5/8
19 3/4
22 7/8
3
1. SPECIFICATIONS
Item Cooling capacity Heating capacity Power source Power consumption Power factor Running current Starting current Operating noise (SPL) Refrigerant Interconnection pipe Condensate drain pipe diameter Appearance colour Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output Ceiling Panel Model Appearance Colour Dimensions Net Weight Air Filter Specifications are subject to change without notice Height Width Depth Height Width Depth Model kW kW Phase V Hz kW % A A dB(A) mm mm mm mm mm mm kg
RAV-104TUH-1-PE 2. 5 2. 8 1 220-240 50 0. 07 93 0. 33 0. 6 40/36/34 R407C ø12. 7 Flare ø6. 4 Flare ø25. 5 (OD) Grey (galvanized steel & thermal insulation) 190 910 480 23 Finned tube Transverse flow fan 550 7x2 RBC-U134PG(W)-E Silky white (Munsell 2. 9Y8. 9/0. 8) 25 1, 050 550 4. 5 Washable
Indoor Unit (High/Med/Low) Name of Refrigerant Larger side size Coupler style Smaller side size Coupler style
m3/hr W
mm mm mm kg
4
1. SPECIFICATIONS
Item Cooling capacity Heating capacity Power source Model kW kW Phase V Hz kW % A A dB(A) dB(A) kg g/m mm mm m m m m mm COOLING 2. 0 88 9. 9 F-261A 3. 6 4. 2 1 220-240 50 HEATING 2. 15 90 10. 4 COOLING 2. 2 90 10. 6 RAV-164TUH-1-PE 4. 5 5. 0 1 220-240 50 HEATING 2. 2 89 10. 7
Power consumption Power factor Running current Starting current Operating noise (SPL) Refrigerant Refrigerant control
Indoor Unit (High, Med, Low) Outdoor Unit Name of Refrigerant Charge Volume Add. Volume (20-30m) Larger side size Coupler style Smaller side size Coupler style Standard length Maximum actual pipe length (of one way) Maximum height difference If Indoor Unit higher If Outdoor Unit higher
Interconnection pipe
60 40/36/34 50 R407C 1. 05 35 Capillary tube & Expansion valve ø12. 7 Flare ø6. 4 Flare 7. 5 30 15 30 ø25. 5 (OD) F-261A Grey (galvanized steel & thermal insulator) 190 910 480 23 Finned tube Transverse flow fan 700 7x2 RAV-134AH-PE Bronze white (Munsell 6Y7. 5/1) 740 880 310 61 Finned tube Propeller fan 2, 700 39 PG330X3F-4LS 1. 5
60 41/37/35 50 R407C 1. 2 35 Capillary tube & Expansion valve ø12. 7 Flare ø6. 4 Flare 7. 5 30 15 30 ø25. 5 (OD) RAV-164TUH-1-PE Grey (galvanized steel & thermal insulator) 190 910 480 23 Finned tube Transverse flow fan 750 7x2 RAV-164AH-PE Bronze white (Munsell 6Y7. 5/1) 740 880 310 61 Finned tube Propeller fan 2, 700 39 PG350X3F-4LS 1. 5
Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Height Width Depth
Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output OUTDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor
mm mm mm kg
m3/h W
Height Width Depth
mm mm mm kg
m3/h W Model Output kW
Protective device CEILING PANEL model Appearance colour Dimensions Net weight Air filter Specifications are subject to change without notice Height Width Depth mm mm mm kg
High pressure switch, fuse, crankcase heater, inner overload relay, bi-metal thermostat RBC-U134PG(W)-E Silky white (Munsell 2. 9Y8. 9/0. 8) 25 1, 050 550 4. 5 Washable RBC-U134PG(W)-E Silky white (Munsell 2. 9Y8. 9/0. 8) 25 1, 050 550 4. 5 Washable
5
1. [. . . ] Volume (20-30m) Larger side size Coupler style Smaller side size Coupler style Standard length Maximum actual pipe length (of one way) Maximum height difference If Indoor Unit higher If Outdoor Unit higher
Interconnection pipe
Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Height Width Depth
Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output OUTDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor
mm mm mm kg
m3/h W
Height Width Depth
mm mm mm kg
m3/h W Model Output kW
Protective device CEILING PANEL model Appearance colour Dimensions Net weight Air filter Specifications are subject to change without notice Height Width Depth mm mm mm kg
fuse, crankcase heater RBC-U134PG(W)-E Silky white (Munsell 2. 9Y8. 9/0. 8) 25 1, 050 550 4. 5 Washable RBC-U134PG(W)-E Silky white (Munsell 2. 9Y8. 9/0. 8) 25 1, 050 550 4. 5 Washable
6
2. CONSTRUCTION VIEWS
2. 1 Indoor Unit RAV-104TUH-1-PE F-261A RAV-164TUH-1-PE RAV-134TU-1-PE RAV-164TU-1-PE
Hanger bolt (4-M10) 840 Drain pipe joint (outer ø25. 5) Refrigerant piping joint (Liquid ø6. 4) Refrigerant piping joint (Gas ø12. 7)
76
480 330
70 76
190
190
156
Wiring connection
A Panel outer dimension 1050 20 40 1050 Panel outer dimension 550 70 40 Ceiling opening 510 480 Hang bolt pitch 410 Ceiling opening 1010 Hang bolt pitch 930 840 110 90 20 40
25
96
131
LG
66 73
550
View A
200
(Unit: mm) 600 Minimum 600 Minimum Space required for service and installation 600 Minimum
7
2. CONSTRUCTION VIEWS
2. 2 Outdoor Unit RAV-134AH-PE RAV-164AH-PE RAV-134A-PE RAV-164A-PE Knock-out hole for drain
(2-20x60 slots) Hole for drain (2xø19 hole) 165 117 40 70
360 280 Refrigerant pipe connection (Gas ø12. 7) 70 50 Refrigerant pipe connection (Liquid ø6. 4)
12
340
12
50 45 Anchor bolt hole (4-12x18slots) 790 Air outlet 880 45 Electric parts box 310 Handle (Both sides)
30
Earth screw (M6) Terminal cover
500
104
90 380
88 320 37 566 Blow out guide mounting hole (4-ø3 embosses) Space required for service (Space for wiring and piping) 100 Outlet 100 500 100 (Space for wiring and piping) 300 500 Outlet 364
When installed with the inlet facing the wall
When installed with the outlet facing the wall
8
18
740
3. WIRING DIAGRAMS
3. 1 RAV-104TUH-1-PE F-261A RAV-164TUH-1-PE
TA
GRY GRY CN04 22 CN15 (TA) 1 1 (LAN) RY04 CN05 (TC) CN07 (FAN) BLK H 11 M ORG 33 L 55 BLU
TC
DM
15 15 14 14 13 13 12 12 11 11 10 10 99 88 77 66 55 44 33 22 11
REMOCON
ORG 11 YEL 22 BLU 33 CN02
CS
RY03 RY02
CN12
UL 7 7 YEL 99 RED RY01 (output)
CN01 (TRANS) ORG 4 BLU 3 BLK 2 YEL 1 WHI
4 3 2 1
CN21
CN09 (WHI) (LOUVER)
BLK
BLK
F3
Interface PCB
33 11 RED RY01 RY06 RY07
TR
TR
CN10 (PUMP)
F
7 7 5 5 RED 3 3 PUR 1 1 GRY
CN03 (L1) (N) (SERIAL) 5 3 1 5 3 1 RED GRY BLK
GRY
SM 01
SM 02
RED WHI WHI
465123 465123
RC01 RC02
1 2 3 4 5 6
1 2 3 4 5 6
WHI RED
FM 02
YEL BLU ORG BLK
WHI
RED WHI
GRN/YEL
1 2 3 4 5 6
1 2 3 4 5 6
WHI RED
FM 01
YEL BLU ORG BLK
Indoor unit
X Y A B C
1
2
3
1 (1 Phase model)
Earth Screw
2
3
F2 L
Power Supply 220/240V ~50Hz
X
Y
A
B
C
N
Central Remote Controller (Optional)
Remote Controller (Optional)
Outdoor unit
Shows terminal block and figures show terminal numbers. Do not operate the units with the magnetic contactor pushed in.
Symbol FM01, 02 RC01, 02 TR TA TC RY01~RY07
Name Symbol Fan Motor F Running Capacitor F3 Transformer DM Sensor SM01, 02 Sensor CS Relay
Name Fuse (PCB) Fuse (Interface) PCB Drain Pump Stepper Motor Float Switch
9
3. WIRING DIAGRAMS
3. 2 RAV-134TU-1-PE RAV-164TU-1-PE
TA
CN04 (TA) ORG 11 YEL 22 BLU 33 CN02 CN05 (TC) CN07 (FAN) BLK H 11 M ORG 33 L 55 77 99 BLU YEL RED
TC
DM
15 15 14 14 13 13 12 12 11 11 10 10 99 88 77 66 55 44 33 22 11
CS
RY02
REMOCON
RY03
CN12
ORG BLU
BLK YEL
7 6 5 4 3 2 1 WHI
7 6 5 CN01 4 (TRANS) 3 2 1
BLK
BLK
RY01 (output)
CN09 (WHI) (LOUVER)
F3
Interface PCB
33 11 RED
RY01 RY14 RY07 RY11
TR
CN10 (PUMP)
F (L1)
5 5 3 3 1 1 1 1 3 3
CN03 7 7 6 4 2 43
TR
(N) 5 5
CN11 (FLOAT) 3 1 3 1
SM 01
8 43 7
SM 02
3 43 1 5
RED WHI WHI
123456 123456
RC02 RC01
1 2 3 4 5 6
1 2 3 4 5 6
WHI RED
FM 02
YEL BLU ORG BLK
WHI
RED WHI
GRN/YEL
1 2 3 4 5 6
1 2 3 4 5 6
WHI RED
FM 01
YEL BLU ORG BLK
Indoor unit
A B C
1
2
3
1
(1 Phase model)
2
3
F2
Earth screw
A
B
C
L
Power supply 220/240V ~50Hz
N
Remote Controller (Optional)
Outdoor unit
Shows terminal block and figures show terminal numbers. Do not operate the units with the magnetic contactor pushed in.
Symbol FM01, 02 RC01, 02 TR TA TC RY01~RY14
Name Symbol Fan Motor F Running Capacitor F3 Transformer DM Sensor SM01, 02 Sensor CS Relay 43
Name Fuse (PCB) Fuse (Interface) PCB Drain Pump Stepper Motor Float Switch Relay
10
3. WIRING DIAGRAMS
3. 3 RAV-134AH-PE RAV-164AH-PE
A
B
C
1
2
3
Indoor unit Outdoor unit
Earth Screw 1 2 3 TR
Earth
RED F2 RY05 F RY07 Wave Control Circuit BLK TE TD
TL BLK WHI WHI 63H
B
RED
6 5 4 RED 3 2 WHI GRY 1
BLU BLK
9
10
11
12
52C
A
11 22 33
L
C
6 5 4 RED 3 FM 2 WHI 0 1
RCo 26HD
20SR
20SF
CM 52C
1 3 13 2 4 14
RCc 49C
L
N CH
31 32
Power Supply 220/240V~50Hz
Shows terminal block and figures show terminal numbers. Broken lines show wiring at site.
Do not operate the units with the magnetic contactor pushed in.
Symbol
20SF RY05, 07 49C 20SR RCc RCo
Name
Solenoid coil (4 way valve) Relay Inner overload relay Solenoid coil (2 way valve) Running capacitor (compressor) Running capacitor (fan motor)
Symbol
CM 52C FMo TL TE 26HD
Name
Compressor Magnetic contactor Fan motor Sensor Sensor Bimetal thermostat
Symbol
F2 63H CH F TR TD
Name
Fuse (T5A) High pressure switch Crankcase heater Fuse (on PCB) Transformer Sensor (Dummy)
11
3. WIRING DIAGRAMS
3. 4 RAV-134A-PE RAV-164A-PE
1
2
3
Indoor unit Outdoor unit
1 Earth screw
A
2
3
52C
B
1
2
RED
RC c CM WHI
3
4
RED
49C BLK
F
13
14
6 3 F2
31 32
6 3 4 2
5
52C
6 3 F1
1
BLK 1 1 BLK ORN 2 2 ORN BLU BLU 33 RED
6 5 4 3 2 WHI 1
6 5 4 3 2 1
BLK ORN BLU RED WHI RED
FM 0
CH
RC o
Surge Absorber L N
Power Supply 220/240V~50Hz
Shows terminal block and figures show terminal numbers. Overcharge or undercharge of refrigerant in the outdoor unit will cause malfunction of the compressor.
The prescribed amount of the replenishment of the refrigerant is shown in the table below:
Additional amount of refrigerant to add at installation site (kg)±50g MODEL (RAV-) 134AH-PE 164AH-PE 134A-PE 164A-PE Filled at Factory Less than 20m Less than 25m Less than 30m Less Less than than 35m 40m -- -- -- -- -- -- -- -- Less Less than than 45m 50m -- -- -- -- -- -- -- -- Less than 5m 0. 79 0. 94 0. 79 0. 94
Recharge amount if unit is reclaimed (kg)±50g Less Less than than 20m 25m 1. 05 1. 2 1. 05 1. 2 1. 23 1. 38 1. 23 1. 38 Less than 30m 1. 4 1. 55 1. 4 1. 55 Less than 35m -- -- -- -- Less than 40m -- -- -- -- Less than 45m -- -- -- -- Less than 50m -- -- -- --
0. 18 0. 35 0. 18 0. 18 0. 18 0. 35 0. 35 0. 35
!ADD ONLY R407C REFRIGERANT TO THESE UNITS
25
7. EXPLODED VIEWS AND PARTS LISTS
7. 1 Indoor Unit
RAV-104TUH-1-PE F-261A RAV-164TUH-1-PE RAV-134TU-1-PE RAV-164TU-1-PE
11 14 13 25/24 22
9 8 12 10
23 1
3 15 17 21 21 4 5
18
6 7 15 2 19 17 18 16 5
20
Ref No. 1 2 3 4 5 6 7 8 9 10 11 11 12 12 13 13
Part No. 43A22007 43020288 43A51002 43A70008 43020253 43071019 43A70009 43A60010 43A60001 43A69008 37555721 43155100 43A69010 43A69005 43A58004 43A58002
Description Blower Base Assembly Fan-C-F Float Switch Pump Assembly Bearing Drain Connection Drain Hose Terminal ABC XY Terminal 1, 2, 3 Interface PC Board MF Capacitor MF Capacitor PC Board (AI) ASM Cont PC IN Transformer (AI) Transformer
Model All All All All All All All All All All RAV-104TUH-1-PE RAV-134/164TU/TUH-1-PE RAV-104/134/164TUH-1-PE RAV-134/164TU-1-PE RAV-104/134/164TUH-1-PE RAV-134/164TU-1-PE
Ref No. 14 15 16 17 18 19 19 19 20 21 22 23 23 24 25
Part No. 43154141 43A21014 43A50006 43A22008 43A22009 43A44060 43A44061 43A44062 43A72010 43A83001 43A88011 43150118 43A50008 43A50004 43A35005
Description Relay LY2F-L Fan Motor (PAF-230-7-4) Sensor Holder Motor Band L Motor Band R Refrigeration Assembly RefrigerationAssembly Refrigeration Assembly Drain Pan Drain Guide Assembly Owner Manual Sensor Room Temperature Sensor Room Temperature Sensor Heat Exchanger TC Adapter
Model RAV-134/164TU-1-PE All All All All RAV-104TUH-1-PE RAV-134TU/TUH-1-PE RAV-164TU/TUH-1-PE All All All RAV-134/164TU-1-PE RAV-104/134/164TUH-1-PE All RAV-104/134/164TUH-1-PE
26
7. EXPLODED VIEWS AND PARTS LISTS
7. 2 Outdoor Unit
RAV-134AH-PE RAV-164AH-PE
41
7 22 13 11 10 9
30 12 21
43 1
17
36
2 18 32 33
3
38
44 15
39 29
23 35
19
5 6 4 25 24 8 27 20 26
34 28
16 31 14 40 42
Ref No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Part No. 43120156 43A21003 43A43016 43049132 43149212 43149198 43A69011 43A49001 43060479 43A60003 43A60001 43152334 43A19001 43119368 43A46004 43162027 43107215 43A63001 43148105 43A45004 43155115 43155080
Description Propeller Fan Fan Motor Condensor Base Spring, B Base Spring, A Spring Buffer PC Board High Pressure Switch Terminal Block, 4P Terminal Block, 2P Terminal Block, 4P Magnetic Contactor Fan Guard Hanger Solenoid Coil Cover, Electrical Parts Sensor Holder Cord Clamp Accumulator Dryer MF Capacitor Compressor MF Capacitor Fan
Model All All All All All All All All All All All All All All All All All All All All All All
Ref No. [. . . ] 23 23 24 25 26 27 28 29 30 31 32 33 34 35 36 38 39 40 41 42 43 44
Part No. 43A41506 43A41507 43146406 43A46013 43A46015 43A46014 43A46016 43146283 43A58003 43046151 43A50001 43A19001 43193063 43157167 43150122 43A60006 43146418 43A47037 43A91016 43A91019 43A91017 43A91023
Description Comp PG330X3F-4LS Comp PG350X3F-4LS Packed Valve (12. 7mm) Packed Valve (6. 35mm) Check Joint Expansion Valve Coil, 2-Way Valve Check Valve Transformer Power 2-Way Valve Sensor Heat Exchanger (TL) Sensor Heat Exchanger (TC) Spring Heater, Crankcase Thermostat, Bi-metal Fuse T5A 4-Way Valve Capi Form ASM Roof Plate ASM Side Cabinet ASM Air-Out Cabinet Fin-Guard (back)
Model RAV-134AH-PE RAV-164AH-PE All All All All All All All All All All All All All All All All All All All All
27
7. EXPLODED VIEWS AND PARTS LISTS
7. 3 Outdoor Unit
RAV-134A-PE RAV-164A-PE
28
19 12 10 9 26 7
8
11 18
30 1
2
3
15
31
20 24
16
5 6 4
23 21 22
17 14 13 27 29
Ref No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG F-261A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG F-261A will begin.