User manual LG F1088QD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG F1088QD. We hope that this LG F1088QD user guide will be useful to you.

Lastmanuals help download the user guide LG F1088QD.


Mode d'emploi LG F1088QD
Download

You may also download the following manuals related to this product:

   LG F1088QD ANNEXE 475 (2915 ko)

Manual abstract: user guide LG F1088QD

Detailed instructions for use are in the User's Guide.

[. . . ] Ask the dealer or authorized company to install the units except room air conditioners for the U. S. A and Canada area. x If the unit is installed improperly, water leakage, electric shock or fire may result. x The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable. x Mount with the lowest moving parts at least 2. 5 m above the floor or grade level. [. . . ] x Make sure that the water dripping from the drain hose runs away correctly and safely. CAUTION x You have just purchased a split-type room air conditioner and it has been installed by your installation specialist. x This device must be installed according to the national electrical rules. x Max input power & current is measured according to IEC standard and input power & current is measured according to ISO standard. E-4 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. 300 mm or more 125 mm or more Wrap the refrigerant pipes and the drain hose up in the absorbent pad and the vinyl tape, refer to page 13. 125 mm or more This drain direction is selectable to left or right. 7metres maximum 600 mm minimum 15metres maximum 300 mm minimum 300 mm minimum 600 mm minimum E-5 Air Conditioner and Accessories The following accessories are supplied with the air conditioner. The quantities are indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for Remote Control (2) Owner's Instruction Booklet (1) TIONS OWNER'S INSTRUC CIONES MANUAL DE INSTRUC L'USO ISTRUZIONI PER ÕES MANUAL DE INSTRUÇ TION MANUEL D'UTILISA EISUNG GEBRAUCHSANW Air Conditioner Split Splut-type Room doméstico sistema Aire acondicionado ambienti ad unità Separate d'aria per Condizionatore ar condicionado tipo Split Aparelho de type séparé Climatiseur de Geteilte raumklimaanlage Installation Manual (1) TIONS OWNER'S INSTRUC CIONES MANUAL DE INSTRUC L'USO ISTRUZIONI PER ÕES MANUAL DE INSTRUÇ TION MANUEL D'UTILISA EISUNG GEBRAUCHSANW Air Conditioner Split Splut-type Room doméstico sistema Aire acondicionado ambienti ad unità Separate d'aria per Condizionatore ar condicionado tipo Split Aparelho de type séparé Climatiseur de Geteilte raumklimaanlage Accessories in the Outdoor Unit Case 4-wire Assembly Cable (1) Drain Plug (1) Rubber LEG (4) The flare nuts are attached to the end of each evaporator in/out pipe or service valve. The 4-wire assembly cable is depending on the option. If they are not supplied, use the standard cable. The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly piping illustrated below. The following connection accessories may be supplied, depending on the option. If they are not supplied, it is recommended that you collect them together before starting to install the air conditioner. Assembly Piping, Ø6. 35mm by 7. 5m (1) Assembly Piping, Ø9. 52mm by 7. 5m (1) PE T3 Foam Tube Insulation (1) Vinyl Tape, Width 50mm (1) Drain Plug (1) Rubber LEG (4) Pipe Clamps A (3) Pipe Clamps B (3) M3. 8 x 20 Screws for Wood (10) M4 x 16 Tapped Screws (10) Drain Hose, length 2m (1) Putty 100g (1) If these accessories are supplied, they are located in the accessory box. E-6 Fixing the Installation Plate Before fixing the installation plate to a wall or window frame, you must determine the position of the 65 mm hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit. When facing the air conditioner in position on the wall, the piping and cable can be connected from the: x Right x Left x Underside (right or left) x Rear (right or left) 1 Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards. If you are fixing the indoor unit to a. . . An all pole disconnection from the power supply must be incorporated in the fixed wiring (3mm). E-8 Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the 65 mm hole drilled in the wall, check that none of the following situations occur. 5 cm less Ditch The hose must NOT slope upwards. The end of the drain hose must NOT be placed in water. Do NOT bend the hose in different directions. Keep a clearance of at least 5 cm between the end of the hose and the ground. Do NOT place the end of the drain hose in a hollow. To install the drain hose, proceed as follows. 1 2 If necessary, connect the 2-metre extension to the drain hose. If you are using the extension, insulate the inside part of the extension drain hose with a shield. Install a drain hose on one of two drain hose holes, then fix tight the end of a drain hose with a clamp. Block the rest you don't use with a rubber stopper. 4 Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight. Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as shown in the illustrations above. The hose will be fixed permanently into position once the whole installation has been tested for gas leaks; refer to page 12 for further details. Shield Drain hose Extension drain hose 3 5 Installing and Connecting the Outdoor Unit Drain Hose When using the air conditioner in the heating mode, ice may accumulate. During de-icing, the condensed water must be drained off safely. Consequently, you must install a drain hose on the outdoor unit, following the instructions below. [. . . ] - Close the valve of the low pressure side of manifold gauge clockwise. - Make sure that pressure gauge show -0. 1MPa(-76cmHg) after about - 10minutes. - This procedure is very important in order to avoid gas leak. - Turn off the vacuum pump - Remove the hose of the low pressure side of manifold gauge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG F1088QD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG F1088QD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag