User manual LG FE-686E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG FE-686E. We hope that this LG FE-686E user guide will be useful to you.

Lastmanuals help download the user guide LG FE-686E.


Mode d'emploi LG FE-686E
Download
Manual abstract: user guide LG FE-686E

Detailed instructions for use are in the User's Guide.

[. . . ] (If applicable) WARNING DURING OPERATION DISPOSING OF THE UNIT x Before throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons. x When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environments. [. . . ] x The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance. x Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency. E-2 Contents x PREPARING YOUR AIR CONDITIONER s Safety Precautions . 4 s Wireless Remote Controller-Buttons and Display . 7 s Wired Remote Controller-Buttons and Display . 10 x RECOMMENDATIONS FOR USE s Operating Recommendations . x TECHNICAL SPECIFICATIONS 11 11 12 14 Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. E-3 ENGLISH View of the Unit The figures are shown in this instruction may differ from yours depending on the model. Indoor Unit 052/070/072 Air outlet Air filter Air inlet Indoor Unit 105/128 Air outlet Air inlet E-4 Outdoor Unit TYPE A TYPE B Air outlet Connection valve Air outlet Connection valve Outdoor Unit TYPE C Air outlet TYPE D Air outlet Connection valve Connection valve Outdoor Unit TYPE E Air outlet TYPE F Air outlet Connection valve Connection valve Note If the heat exchanger in the outdoor unit gets dusty, cooling efficiency may fall. So clean the heat exchanger with water when it becomes dirty. As the temperature of the outside air drops, the heating performance of air conditioner will decrease. If you find that the room is not warm enough, using an additional heating appliance is recommended. When outside temperature is low but humidity is high, frost may form on the outdoor unit at HEAT mode. If this happens: x The heating operation stops. x The defrost mode will be triggered automatically for about 10 minutes. No intervention is required ; after about 10 minutes, the air conditioner operates again normally. If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode, the outdoor unit's fan and compressor may stop at times. This is normal ; simply wait until the air conditioner switches on again. If a power failure occurs while the air conditioner is operating, the unit will be switched off. When the power returns, the air conditioner starts up again automatically. Frost High indoor and outdoor temperatures Power failure Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges, within which the air conditioner can be used. High temperature Low temperature High humidity levels Then. . . [. . . ] The automatic protection feature may be triggered and the air conditioner stopped. A water leakage or some other malfunction may happen if the heat exchanger freezes. Water may condense on and drip from the surface of the indoor unit if it is used for a long periods. Mode Heating Cooling Drying Outdoor Temperature -15°C to 24°C approx. - 5°C to 43°C approx. Indoor Temperature 27°C or less 21°C to 32°C approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG FE-686E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG FE-686E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag