User manual LG FFH-360VA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG FFH-360VA. We hope that this LG FFH-360VA user guide will be useful to you.

Lastmanuals help download the user guide LG FFH-360VA.


Mode d'emploi LG FFH-360VA
Download
Manual abstract: user guide LG FFH-360VA

Detailed instructions for use are in the User's Guide.

[. . . ] · Perform installation work properly according to this Installation Manual. Improper installation may result in electric shock or fire. Any modification may cause a malfunction, resulting in overheating or fire. CAUTION · Perform wiring correctly in accordance with specified the current capacity. Failure to do so may result in short-circuiting, overheating, or fire. [. . . ] Failure to do so may result in short-circuiting, overheating, or fire. · Connect the specified cables for the terminals securely to prevent external forces from affecting them. Failure to do so may result in disconnection, overheating, or fire. 1 Introduction nApplications/Functions/Specifications Applications/Functions/Specifications · Applications The TCS-NET Relay Interface is used to connect air conditioners (with TCC-LINK installed) to the air conditioner control system. · Functions The TCS-NET Relay Interface converts signals between TCC-LINK and RS-485. · Specifications Power supply Current Power consumption Operating temperature/humidity Storage temperature Chassis material Dimensions Mass 220 - 240 V, AC 50/60 Hz 18 mA 2. 4 W 0 to 40 °C, 10 to 90% RH (no condensation) -20 to +60 °C Galvanized sheet metal 0. 8t (no coating) 66 (H) x 170 (W) x 200 (D) mm 1 kg External View 200 1 2 22 78 6- 5. 5 mounting holes 78 22 Parts name Case Case lid Grommet Grommet Grommet for power supply 66 63. 6 Specifications Galvanized sheet metal Galvanized sheet metal C30-SG20A C30-SG20A C30-SG20A 3 4 5 22 78 78 22 2 Bottom side 156 170 Top side 147 Before Installation Check the following package contents. No. 1 2 3 Item TCS-NET Relay Interface Installation Manual Screw Quantity Remarks 1 1 4 M4 x 12mm tapping screws Use the following wiring materials to connect the signal lines. 1 Signal line For TCC-LINK Type Wire size Length Type Wire size Length Description 2-core shield wires 1. 25 mm2, 1000m max. (total length including 2. 00 mm2, 2000m max. air conditioner area) 2-core shield wires 1. 25 mm2, 500m max. (total length) 2 For RS-485 1 Installation TCS-NET Relay Interface Installation Method and Orientation There are five installation methods for this relay interface as shown below: surface mount and wall mounts. Use the attached screws. No good REQUIREMENT Do not install the unit in any of the following places. · Humid or wet place · Dusty place · Place exposed to direct sunlight · Place where there is a TV set or radio within one meter · Place exposed to rain (outdoors, under eaves, etc. ) Installation Space and Maintenance Space A side space for connecting through cable inlets and an upper space for maintenance must be reserved before installation. CAUTION: The SW1 setting is read when the power is turned on. Push the reset switch SW7 after changing the address. 5 Remote controller Remote controller CAUTION: RS-485 signals A and B have polarity. Be careful when connecting the RS-485 wires. Indoor unit Central remote controller ADDRESS The shield of RS-485 cable should be open and insulated. It is not connected to the terminal block. RS-485 ON Outdoor unit U4 U3 Outdoor unit SW5 Remote controller Remote controller Red A Orange Crimp 3 wires with B Y ellow a closed end wire Brown joint. U4 U3 1 2 SW1 1 Indoor unit NL Indoor unit Central remote controller U4 U3 ADDRESS 8 Indoor unit NL 3 Setting The following settings are necessary to use TCS-NET Relay Interfaces. · SW1 TCS-NET Relay Interface address set switch When two or more TCS-NET Relay Interfaces are used, set a different address for SW1 to avoid address duplication. Assign addresses in an ascending order. CAUTION · Set relay interface addresses according to the air conditioner address table. For the relay interface whose address SW1=1, perform terminator resistor setting. · When the SW1 setting has been changed, push the reset switch SW7. · SW2 Test switch · SW3 Test switch · SW4 Test switch Not used during operation. Set these switches to zero (0) or "all OFF". [. . . ] · When the SW1 setting has been changed, push the reset switch SW7. · SW2 Test switch · SW3 Test switch · SW4 Test switch Not used during operation. Set these switches to zero (0) or "all OFF". · SW5 RS-485 terminator resistor select switch Set "120 ohm" only when the relay interface address SW=1, and set "open" for other relay interfaces. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG FFH-360VA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG FFH-360VA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag