[. . . ] · Perform installation work properly according to this Installation Manual. Improper installation may result in electric shock or fire. Any modification may cause a malfunction, resulting in overheating or fire.
CAUTION
· Perform wiring correctly in accordance with specified the current capacity. Failure to do so may result in short-circuiting, overheating, or fire. [. . . ] Failure to do so may result in short-circuiting, overheating, or fire. · Connect the specified cables for the terminals securely to prevent external forces from affecting them. Failure to do so may result in disconnection, overheating, or fire.
1
Introduction
nApplications/Functions/Specifications Applications/Functions/Specifications · Applications
The TCS-NET Relay Interface is used to connect air conditioners (with TCC-LINK installed) to the air conditioner control system.
· Functions
The TCS-NET Relay Interface converts signals between TCC-LINK and RS-485.
· Specifications
Power supply Current Power consumption Operating temperature/humidity Storage temperature Chassis material Dimensions Mass 220 - 240 V, AC 50/60 Hz 18 mA 2. 4 W 0 to 40 °C, 10 to 90% RH (no condensation) -20 to +60 °C Galvanized sheet metal 0. 8t (no coating) 66 (H) x 170 (W) x 200 (D) mm 1 kg
External View
200
1 2 22 78 6- 5. 5 mounting holes 78 22
Parts name Case Case lid Grommet Grommet Grommet for power supply
66 63. 6
Specifications Galvanized sheet metal Galvanized sheet metal C30-SG20A C30-SG20A C30-SG20A
3 4
5
22
78
78
22
2
Bottom side 156 170
Top side
147
Before Installation
Check the following package contents.
No. 1 2 3 Item TCS-NET Relay Interface Installation Manual Screw Quantity Remarks 1 1 4 M4 x 12mm tapping screws
Use the following wiring materials to connect the signal lines. 1 Signal line For TCC-LINK Type Wire size Length Type Wire size Length Description 2-core shield wires 1. 25 mm2, 1000m max. (total length including 2. 00 mm2, 2000m max. air conditioner area) 2-core shield wires 1. 25 mm2, 500m max. (total length)
2
For RS-485
1
Installation
TCS-NET Relay Interface Installation Method and Orientation
There are five installation methods for this relay interface as shown below: surface mount and wall mounts. Use the attached screws.
No good
REQUIREMENT Do not install the unit in any of the following places. · Humid or wet place · Dusty place · Place exposed to direct sunlight · Place where there is a TV set or radio within one meter · Place exposed to rain (outdoors, under eaves, etc. )
Installation Space and Maintenance Space
A side space for connecting through cable inlets and an upper space for maintenance must be reserved before installation. CAUTION: The SW1 setting is read when the power is turned on. Push the reset switch SW7 after changing the address.
5
Remote controller
Remote controller
CAUTION: RS-485 signals A and B have polarity. Be careful when connecting the RS-485 wires.
Indoor unit Central remote controller
ADDRESS
The shield of RS-485 cable should be open and insulated. It is not connected to the terminal block.
RS-485
ON
Outdoor unit
U4 U3
Outdoor unit
SW5
Remote controller
Remote controller
Red A Orange
Crimp 3 wires with B Y ellow a closed end wire Brown joint.
U4 U3
1
2
SW1
1
Indoor unit
NL
Indoor unit Central remote controller
U4 U3
ADDRESS
8
Indoor unit
NL
3
Setting
The following settings are necessary to use TCS-NET Relay Interfaces. · SW1 TCS-NET Relay Interface address set switch When two or more TCS-NET Relay Interfaces are used, set a different address for SW1 to avoid address duplication. Assign addresses in an ascending order.
CAUTION
· Set relay interface addresses according to the air conditioner address table. For the relay interface whose address SW1=1, perform terminator resistor setting. · When the SW1 setting has been changed, push the reset switch SW7. · SW2 Test switch · SW3 Test switch · SW4 Test switch Not used during operation. Set these switches to zero (0) or "all OFF". [. . . ] · When the SW1 setting has been changed, push the reset switch SW7. · SW2 Test switch · SW3 Test switch · SW4 Test switch Not used during operation. Set these switches to zero (0) or "all OFF". · SW5 RS-485 terminator resistor select switch Set "120 ohm" only when the relay interface address SW=1, and set "open" for other relay interfaces. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG FFH-360VA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.