[. . . ] Visit us at http://www. lgservice. com
LG
ENGLISH
LG Room Air Conditioner
OWNER'S MANUAL
Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm).
ITALIANO ESPAÑOL
Dear Owner Thank you for installing LG air conditioner. Your best choice guarantees you a great performance and service to make your life comfortable & pleasant.
FRANÇAIS DEUTSCH
IMPORTANT
· Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. · Please retain this owner's manual for future reference after reading it thoroughly.
P/No. : MFL37233902
Room Air Conditioner Owner's Manual
TABLE OF CONTENTS
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Temporary Use of an Adapter . . . . . . . . . . . . . . . 6 Temporary Use of an Extension Cord . . . 6 Symbols used in this Manual. . . . . . . . . . . . . . . . . 6 Product Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indoor Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operation Indication Lamps . . . . . . . . . . . . . . . . . . 7 Outdoor Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 How to insert the Batteries . . . . . . . . . . . . . . . . . . . . 8 Wireless Remote Controller Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Operating Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Remote Control Operation . . . . . . . . . . . . . . . . . . . . 9 Auto Restart Function. . . . . . . . . . . . . . . . . . . . . . . . . . 14 Maintenance and Service . . . . . . . . . . . . . . . . . . . . . . 15 Indoor Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Operation Tips!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Self-Diagnosis Function . . . . . . . . . . . . . . . . . . . . . . 16 Troubleshooting Tips!Save time and money!. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Call the service immediately in the following situations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
FOR YOUR RECORDS
Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. [. . . ] · There is risk of personal injury.
Do not step on or put anyting on the product. (outdoor units) · There is risk of personal injury and failure of product. Be cautious when unpacking and installing the product. · Sharp edges could cause injury.
Do not insert hands or other objects through the air inlet or outlet while the product is operating. · There are sharp and moving parts that could cause personal injury. Do not tilt the unit when removing or uninstalling it. · The condensed water inside can spill .
If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas. · The refrigernat gas can cause frostbite (cold burn) If the refrigerant gas leaks during the installation, ventilate the area immediately. · Otherwise it can be harmfull for your health.
Do not mix air or gas other than the specified refrigerant used in the system . · If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. · There is risk of fire or product failure.
Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards.
Do not recharge or disassemble the batteries. Do not expose your skin or kids or plants to the cool or hot air draft. · This could harm to your health.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. · The chemicals in batteries could cause burns or other health hazards.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. · Moisture may condense and wet or damage furniture.
Do not drink the water drained from the product. Please see the information specific to your indoor unit type.
ENGLISH
Indoor Units
Standard Split Type Display panel LED indicators
Air inlet Grille tab Plasma filter (Optional) Front grille ON/OFF button
Air filter Louvers (Vertical blades) Signal receiver
Air outlet
Flap (Horizontal blade)
Operation Indication Lamps
On/Off Timer : Lights up during the system operation, error code and auto restart setting. : Lights up during timer operation. (non-Inverter Model) Lights up during timer operation or sleep mode auto operation (Inverter Model only) : Lights up during outdoor unit operation. (Cooling model only)
Defrost mode : Lights up during defrost mode or *hot start operation (Heat pump model only)
OUT DOOR
Outdoor unit operation
* Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit. * In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency.
Outdoor Units
Air intake vents Connecting wires Refrigerant pipes
Air outlet vents Base plate Drain hose
Owner's Manual 7
Operating Instructions
Operating Instructions
How to insert the Batteries
1. [. . . ] · Indoor pipe temperature thermistor open/short.
3 sec
3 sec
3 sec
16 Room Air Conditioner
Maintenance and Service
Troubleshooting Tips!Save time and money!
The air conditioner may be operating abnormally when:
Problem Possible Causes I The air conditioner is unplugged. I The fuse is blown/circuit breaker is tripped. Air conditioner does not start I Power failure. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG G12AHS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.