[. . . ] Installing and Connecting the Drain Hose of the Indoor Unit . Changing Direction of the Drain Hose . .
9 10 12 13 14 15 16
COMPLETING THE INSTALLATION Purging the Connected Pipes . .
17 18 19 20 21 21
In this manual, you may find model names written in simplified forms as indicated in following table.
Model Names ASE ASR ASU 09 12 18 24 Included Models Remark
AS09E, AS12E, AS18E, AS24E Grouping was done by AS09R series. [. . . ] Place with no plants (especially climbing plants) and where small animal can not access.
CAUTION
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil - Where sulfide gas exists
- Salty environment such as seaside areas - Other special atmosphere areas
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
300mm or more 125mm or more Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. You can select the direction of draining (left or right). 125mm or more
CAUTION:
'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration) ' H ' meters maximum total pipe length
600mm minimum 300mm minimum
' L ' meters maximum total pipe length
300mm minimum 600mm minimum
Model 09 12 18 24
L 15 15 15 20
H 7 7 7 8
Make at least one round: It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
E-5
MID_AS09U series_IM_30921A_E_9. 23. 09. indd 5
2009-11-20 15:02:51
ENGLISH
PREPARING FOR INSTALLATION
Choosing the Installation Location (Continued)
Space Requirements for Outdoor Unit
When installing 1 outdoor unit Unit : mm
hen the air outlet is opposite the wall W
300 or more
hen the air outlet is towards the wall W
hen 3 sides of the outdoor unit are W
blocked by the wall
300 or more
he upper part of the outdoor unit and T
the air outlet is towards the wall
1500 or more
Air intake
2000 or more
150 or more
600 or more
he upper part of the outdoor unit and T
the air outlet is opposite the wall
500 or more 300 or more
hen the walls are blocking front and W
the rear side of the outdoor unit
1500 or more 300 or more
Figure Description
Top view
Air intake
Side view
Air outlet Air outlet
,
Air flow direction.
CAUTION
f installation is done in inappropriate space, unit may generate sound and I cause bad effect on the product. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the:
Right (A)
Direction of pipe
Left (B) Underside_right (C) Rear_right or left (D)
A D C D
B
1
Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. CAUTION Make sure to drill only one hole after choosing the direction of the pipe.
(Unit : mm) Pipe hole (Ø65mm)
27
AS09/AS12
120
68
2
Fix the indoor unit. If you fix the indoor unit on a wall (1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. Note If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.
(Unit : mm) Pipe hole (Ø65mm)
34 34 140 68
AS18/AS24
Plastic Anchor <20mm Wall
If you fix the indoor unit on a window frame (1) Determine the positions of the wooden uprights to be attached to the window frame. (2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit. (3) Attach the installation plate to the wooden upright using tapping screws. If you fix the indoor unit on a gypsum board (1) Use stud finder to find out locations of the studs. The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall: Right(A) Left(B) Underside(C) Rear
A C
B
1 2 3
Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear. Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:
Outer Diameter ø6. 35 mm ø9. 52 mm ø12. 70 mm ø15. 88 mm ø19. 05 mm ø22. 23 mm Torque (kgf·cm) 140~170 250~280 380~420 440~480 990~1210 990~1210
Note
If you want to shorten or extend the pipes, refer to page 14.
4 5
Cut off the remaining foam insulation. If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole. The pipe should not project from the rear of the indoor unit. The bending radius should be 100 mm or more. Pass the pipe through the hole in the wall. For further details on how to connect to the outdoor unit and purge the air, refer to page 17. The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test; refer to page 19 for further details.
6 7
Note
CAUTION
Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage. [. . . ] The purge time is normal.
Refer to the Service Manual for further details.
CAUTION
The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor. Always contact the service center or a professional installation agency for product installation.
Performing the Gas Leak Tests
Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). Indoor unit
C D
Using a leak detector, check the. . . Valves A and B.
Outdoor unit
A
B
E-18
MID_AS09U series_IM_30921A_E_9. 23. 09. indd 18
2009-11-20 15:03:13
COMPLETING THE INSTALLATION
Fixing the Indoor Unit in Place
Perform the following work on the area where gas leak test was done priorly.
ENGLISH <Figure A> Insulation Pipes
Installation plate Vinyl tape Connecting wires Drain hose Connecting pipes
After checking for gas leaks in the system, insulate the pipe, hose and cables. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GL-268GPASWQTM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.