User manual LG GL-302QMASWQOM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GL-302QMASWQOM. We hope that this LG GL-302QMASWQOM user guide will be useful to you.

Lastmanuals help download the user guide LG GL-302QMASWQOM.


Mode d'emploi LG GL-302QMASWQOM
Download
Manual abstract: user guide LG GL-302QMASWQOM

Detailed instructions for use are in the User's Guide.

[. . . ] If an above action is executed during the fan operation, the protective control works to stop the unit operation, and the check code "P12" may be issued. When the desired operation has finished, be sure to reset the system to clear "P12" error code using the leak breaker of the indoor unit. Then push the operation stop button of the remote controller to return to the usual operation. CONTENTS SAFETY CAUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] NO Are characteristics of TD sensor resistance value normal?YES NO * Refer to Characteristics-4. Check and correct the charged refrigerant amount. Improve and delete the cause Replace TD sensor. Check CDB. Defect Replace * For RAV-SM562AT-E, replace control P. C. board. ® [H01 error] Is power voltage normal?YES NO Improve power line. YES Is not abnormal overload?NO Is the circuit detected by current sensor normal?YES NO Improve and delete the cause. Check and correct circuit cables. Check IPDU. Defect Replace * For RAV-SM562AT-E, replace control P. C. board. ® ­ 96 ­ [P04 error] Is high-voltage protective operation by TE sensor normal?YES NO Is connection of cabling connector normal?YES NO Correct connection of cabling connector. Check TE sensor. If [E03] occurs during an operation, the air conditioner stops. [F29 error] / [12 error] [F29 error] or [12 error] indicates detection of trouble which occurred on IC10 non-volatile memory (EEPROM) on the indoor unit P board during operation of the air conditioner. . C. * If EEPROM has not been inserted when the power was turned on or if EEPROM data never be read/written, the automatic address mode is repeated. In this time, the central controller displays [97 error]. (Power ON) (Approx. 3 minutes) [SET] is displayed on main remote controller. (Repetition) LED (D02) on indoor unit P. C. 10 seconds. Reboot (Reset) [P31 error] (Sub indoor unit) When the master unit of a group operation has detected [E03], [L03], [L07], or [L08] error, the sub unit of the group operation detects [P31 error] and then it stops. There is no display of the check code or alarm history of the main remote controller. (In this model, the mode enters in automatic address set mode when the master unit has detected [E03], [L03], [L07], or [L08] error. ) ­ 99 ­ 10-4-2. Relational Graph of Temperature Sensor Resistance Value and Temperature 20 40 TA sensor 30 TC, TCJ sensor Caracteristics-2 Resistance (k9) 10 Caracteristics-1 Resistance (k9) 20 10 0 10 20 30 40 50 0 ­10 0 10 20 30 40 50 60 70 Temperature [°C] Temperature [°C] 200 20 TE, TO, TS sensor Caracteristics-3 Resistance (k9) (10°C or lower) 100 Resistance (k9) (10°C or higher) 10 0 -10 0 10 20 30 40 50 60 70 0 Temperature [°C] TD sensor 200 Caracteristics-4 20 Resistance (k9) (50°C or lower) 100 Resistance (k9) (50°C or higher) 10 0 50 100 0 Temperature [°C] ­ 100 ­ 11. BOARD [Requirement when replacing the service indoor P. C. [. . . ] When the power cord size does not match with Pshape clamp, procure the most appropriate one at the local site. ­ 190 ­ No. Assembly 3 Photo / Explanatory diagram Procedure Return a set of the refrigeration cycle assembly into the outdoor unit base plate and reassemble sound insulation board, partition plate assembly, fan motor assembly, and side cabinet (R/L) as original. Fix the thermostat fixing plate to the side cabinet (R), built in the inverter assembly, and then connect various cables. After then, incorporate front cabinet, upper cabinet, wiring cover, and valve cover as before. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GL-302QMASWQOM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GL-302QMASWQOM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag