[. . . ] 6 Checking the name of the parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Checking the remote controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Basic function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Adjusting the air flow direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Then, pull the Full HD filter towards you and slide it down.
Full HD filter
Cleaning the Full HD filter
Washable foam based Full HD filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing.
Open the panel and put the Full HD filter out.
Clean the Full HD filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.
Insert the Full HD filter back in its original position and close the front panel.
Dry the Full HD filter in a ventilated area.
· CleantheFullHDfilterevery2weeks. Cleaningtermmaydifferdependingontheusageandenvironmental conditions. · IftheFullHDfilterdriesinaconfined(orhumid)area, odorsmaygenerate. Ifitoccurs, re-cleananddryitina well-ventilated area.
20
Australia_AQV09K_IBIM_32451A_E_6. 28. 11. indd 20 2011-6-28 10:27:48
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly. Type Description Clean the Full HD filter (1) Indoor unit Clean the condensate drain pan (2) Thoroughly clean the heat exchanger (2) Clean the condensate drain pipe (2) Replace the remote controller batteries (1) Clean the heat exchanger on the outside of the unit (2) Clean the heat exchanger on the inside of the unit (2) Clean the electric components with jets of air (2) Outdoor unit Verify that all the electric components are firmly tightened (2) Clean the fan (2) Verify that all the fan assembly is firmly tightened (2) Clean the condensate drain pan (2)
Every 2 weeks
Every 3 months
Every 4 months
Once a year
: This check mark requires checking the indoor/outdoor unit periodically.
Follow the description to maintain the air conditioner properly. (1) The described operations should be performed more frequently if the area of installation is very dusty. (If the good' sleep mode is operating in Heat mode, you can adjust the air flow direction) · CheckifyouhaveselectedAuto/Dry/Turbo/ /d'light Cool mode. In these mode, fan speed is set to Auto and you cannot adjust the fan speed. · Checkifyourbatteriesaredepleted. · Makesurenothingisblockingyourremotecontrollersensor. · Checkthattherearestronglightingapparatusneartheairconditioner. Stronglightwhich comes from fluorescent bulbs or neon signs may interrupt the electric waves. · CheckifyoupresstheSet/Cancel button on the remote controller after you have set the time. · PressthePower button or disconnect the power plug/switch off the auxiliary power switch. If the indicator is still blinking, contact the service center. · Checkiftheapplianceisrunninginasmokyarea. Ventilatetheroomoroperatetheair conditioner in Fan mode for 1~2 hours. (We do not use smelly components in the air conditioner. ) · CleantheFullHDfilteriftheyaredirty. ReplacetheDeodorizingfilterifitisdirty.
The temperature adjustment is not working. Cool/Warm air does not come out of the air conditioner.
Air flow adjustment is not working. [. . . ] · Approximately3~5minuteslater, outdoorunitwillstarttooperateandthe Cool or Warm air will blow out. · After12minutesofstationaryconditionchecktheindoorunitairtreatment.
2. Press the Mode button to select Cool or Heat mode.
Cooling mode (indoor unit check) Inlet air temp. - Outlet air temp: From 10°K to 12°K ( indicative delta T) Heating mode (indoor unit check) Outlet air temp. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GL-T242QL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.