[. . . ] EXPLODED VIEWS AND PARTS LIST
· This air conditioner is charged with HFC (R410A) that doesn't deplete the Ozone layer. · This air conditioner requires special installation for the refrigerant R410A.
2
FILE NO. SPECIFICATIONS
RAS-24UKHP-ES-1 MODEL ITEM Capacity kW Phase Power source Power consumption Power factor Running current Starting current Moisture removal Noise Refrigerant Refrigerant control Gas side size Connection type Liquid side size Interconnection pipe Connection type Maximum length (One way) Maximum height difference INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 10 ~ 24 Model Output W IOL, Td Sensor m3/h W 3400 3600 3400 3600 65 PA290X3F-4MS 2200 IOL 15 ~ 43 IOL, Td Sensor Automatic louver 15 ~ 43 10 ~ 24 15 ~ 43 3400 Width Depth mm mm mm kg 65 GR-151SVF 690 880 310 62 Finned tube Propeller fan 3600 1800 2000 1800 2000 42 PA225X3F-4L 1500 IOL 1800 2000 50 830 300 48 Medium fan Low fan m /h m3/h m3/h W RAS-24UA-ES-1
3
RAS-24UKP-ES-1 RAS-24UA-ES-1 Cooling 220V 6. 40 240V 6. 45
RAS-18UKHP-ES2 RAS-18UAH-ES2 Cooling Heating 220V 240V 220V 240V 5. 00 5. 05 5. 45 5. 55 1
RAS-18UKP-ES2 RAS-18UA-ES2 Cooling 220V 5. 05 240V 5. 10
GR-151SVF Cooling Heating 220V 240V 220V 240V 6. 30 6. 30 6. 80 6. 90
V Hz kW % A Indoor/Outdoor A lit/h Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount kg mm mm 1. 6 dB dB 56-57 2. 5 45/41/37 57-58 56-57 2430 2510 2355 2435 96 92 95 90 220V 240V 220V 240V 0. 3/ 0. 3/ 11. 2 11. 1 0. 3/11. 2 54 2. 7 2360 96 220V 0. 3/10. 9
220 240 50 2440 92 240V 0. 3/10. 8 1850 1900 1648 1718 98 0. 2/ 8. 4 97 94 92 220V 240V 220V 240V 0. 2/ 0. 2/ 0. 2/ 8. 0 7. 9 7. 7 47 2. 0 42/39/35 51-52 R410A 1. 3 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 15*1 25*2 10 RAS-24UKHP-ES-1 RAS-24UKP-ES-1 298 998 208 12 Finned tube Cross flow fan 950 750 600 950 800 650 950 750 600 20 Honeycomb woven filter with PP frame RAS-18UAH-ES2 538 780 RAS-18UA-ES2 750 650 530 800 700 570 750 650 530 RAS-18UKHP-ES2 20*2 8 RAS-18UKP-ES2 1. 2 52-53 51-52 2. 0 1820 98 220V 0. 2/8. 2 1870 97 240V 0. 2/7. 8
m m
mm mm mm kg
Width Depth
3
FILE NO. SVM-03009
Note : 1 · Capacity is based on the following temperature conditions. [. . . ] <Remote control selector switch> · When two indoor units are installed in the same room or the adjacent two rooms, they may be controlled simultaneously with a single remote control. To prevent this, set either unit and its remote control to B setting. (Both units are set to A setting before shipment. ) · The remote control signal is not recived when the indoor unit setting is different from the remote control one. Set the remote control selector switch with the indoor unit. 1) Turn the circuit breaker of the main power switch off before setting the selector switch. 2) Remove the Air inlet grille and Front panel. (Refer to page 63, 10-1) 3) Select the terminal of selector switch from [A position] to [B position].
Slector switch
PRESET
A B A B
2. Set the remote control selector switch with the remote control [B] is indicated on the liquid crystal display when setting remote control selector switch to B. [A] is not indicated on the display even if the selector switch is set to A. 1) Load the remote control with the batteries. 2) Press the [CHECK] button using something with sharp point. The compressor is not turned off even though the room temperature is in the range that the compressor is turned off. The compressor is not turned on and off even though the thermo control is operated in the Dry operation. lamp is indicated when the Heating operation starts.
Descriptions
The OPERATION lamp blinks to indicate that power is turned on. If the [START/STOP] button is pressed, the lamp stops blinking. The indoor fan motor speed is automatically controlled in the Dry operation. The compressor has a function that it is not turned off for 3 minutes after it is turned on even though the room temperature is in the range that the compressor is turned off. In the Dry operation, the compressor is turned on and off automatically at the regular intervals, independent of the thermo control. lamp is indicated during the Defrosting operation or if the indoor heat exchanger temperature is low when the Heating operation starts. At this time, the indoor fan motor stops to prevent cold air from blowing in the room. When the indoor heat exchanger temperature is high, the outdoor fan motor is stopped by the high-temperature limit control operation. The compressor is not turned on in the restart delay timer (3-minutes timer) operation. [. . . ] SVM-03009
10-4 Outdoor Unit (RAS-18UA-ES2)
No.
1
Part name
Common procedure
Procedures
1) Stop the operation of the air conditioner and turn off its main power supply or remove the power supply cord. (2 screws 4 x 10L) 3) Remove 2 cord clamps (4 screws 4 x 22L) and disconnect the power supply cord and connecting cable after removing 6 screws on the terminal block and 1 ground screw on the electrical parts base. (8 scerws 4 x 10L) (Pull the front lower portion toward you, and pull out it upward to remove it. ) 5) Remove the back cabinet. (4 screws 4 x 10L)
Remarks
Remove 8 screws 4 x 10L
4 screws 4 x 22L
4 screws 4 x 10L
2
Running capacitor for compressor
1) Perform the common procedure 1 2) Remove the capacitor band. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-151SVF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.