Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-201RPXXASGQNP. We hope that this LG GR-201RPXXASGQNP user guide will be useful to you.
Lastmanuals help download the user guide LG GR-201RPXXASGQNP.
Detailed instructions for use are in the User's Guide.
[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Hi-POWER indicator Indicates when the Hi-POWER operation starts. Press the Hi-POWER button to start and press it again to stop the operation. (PRESET) indicator Flashes for 3 seconds when the PRESET button is pressed during operation. mark is shown when holding down the The button for more than 3 seconds while the mark is flashing. Press another button to turn off the mark. ECO indicator Indicates when the ECO is in activated. Press the ECO button to start and press it again to stop operation. A, B change indicator remote controller When the remote controller switching function is set, "B" appears in the remote controller display. (When the remote controller setting is "A", there is no indication at this position. )
8 9
10
1 12
9
2
13
10 Comfort 11 Quiet
sleep Indicates when comfort sleep is activaled. Press comfort sleep button to selectter
Indicates when quiet is activated. Press quiet button to start and press it again to stop operation. If a leak of refrigerator gas occurs inside the room, an oxygen deficiency can occur.
60 0
mm
or
mo
re
Extension drain hose (Not available, provided by installer)
600 mm
In case of right or left piping
cut dot-line area
(B)
or
(A)
mo re
Before installing the wireless remote controller Loading Batteries 1. Insert 2 new batteries (AAA type) following the (+) and () positions. 2 Wireless remote controller
65
A C L
3 Batteries
10-2. Optional Parts, Accessories and Tools
10-2-1. Optional Installation Parts
Part Code
Parts name Refrigerant piping
Q'ty One each
A
Liquid side : 6. 35 mm Gas side : 9. 52 mm (RAS-(B) 10, 13UFV Series) 12. 70 mm (RAS-(B) 18UFV Series)
B C
Pipe insulating material (polyethylene foam, 8 mm thick)
1
Putty, PVC tapes
One each
<Fixing bolt arrangement of outdoor unit>
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind. Use 8 mm or 10 mm anchor bolts and nuts. If it is necessary to drain the defrost water, attach drain nipple 9 and cap water proof 10 to the bottom plate of the outdoor unit before installing it.
108 mm 125 mm
25
m
28 mm
Air inlet
102 mm
320 mm
86 mm
m
* Drain nipple and cap water proof are packed in outdoor unit.
Air outlet
600 mm
90 mm
Drain outlet
Fig. 10-2-1
When using a multi-system outdoor unit is used, refer to the installation manual provided with the model concerned.
66
10-2-2. Accessory and installation parts
Part No. Part name (Q'ty) Part No.
Part name (Q'ty)
1
Installation plate x 1
4
Remote control holder x 1
7
Flat head wood screw 3. 1 x 16 l x 2
ONE-TOUCH
FLOOR
SWING
QUIET
PRESET
SLEEP
CHK FILTER
AUTO
FIX
ON
TIMER
TEMP
Hi-POWER ECO
2
5
Filter (RB-A620DE) x 2
OFF
Wireless remote control x 1
CLOCK
COMFORT SLEEP
8
Insulation sheet x 1
MODE
FAN
AUTO
CLR
SET
3
Battery x 2
Others
Name
Owner's manual Installation manual
6
Mounting screw 4 x 25 l x 8
9
Drain nipple* x 1
10
Cap water proof x 2
The part marked with asterisk (*) is packaged with the outdoor unit.
67
10-2-3. Installation/Servicing Tools
Changes in the product and components
In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged accidentally, the service port diameter of the outdoor unit control valve (3 way valve) has been changed. [. . . ] It is dangerous for these coverings to be damaged since damage may cause electric shocks and/or a fire. CAUTION After replacing the parts, check whether the positions where the sensors were installed are the proper positions as instructed. The product will not be controlled properly and trouble will result if the sensors have not been installed in their proper positions.
119
13. 201 202 203 204 205 206 207 208 209 210 211 211 211
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-201RPXXASGQNP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-201RPXXASGQNP will begin.