Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-232MF. We hope that this LG GR-232MF user guide will be useful to you.
Lastmanuals help download the user guide LG GR-232MF.
Detailed instructions for use are in the User's Guide.
[. . . ] EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy for Heat pump model) 11-2 Indoor Unit (E-Parts Assy for Cooling model) 11-3 Indoor Unit (RAS-07, 10, 13UKHP-E4, UKP-E4) 11-4 Indoor Unit (RAS-07, 10, 12, 13UKPX4) 11-5 Outdoor Unit (RAS-13UAH-E4) 11-6 Outdoor Unit (RAS-10UAH-E4) 11-7 Outdoor Unit (RAS-13UA-E4) 11-8 Outdoor Unit (RAS-10UA-E4) 11-9 Outdoor Unit (RAS-13UAX4, RAS-12UAX4) 11-10 Outdoor Unit (RAS-10UAX4) 11-11 Outdoor Unit (RAS-07UAX4, RAS-07UA-E4) 11-12 Outdoor Unit (RAS-07UAH-E4)
-2-
FILE NO. SPECIFICATIONS
MODEL RAS-13UKHP-E4 / RAS-13UAH-E4 RAS-13UKP-E4 / RAS-13UA-E4
ITEM Capacity 220 V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 49 5. 50 1. 23 99 3. 55
Cooling 240 V 3. 60 220 V 4. 10
Heating 240 V 4. 15 1Æ 220 - 240 50 1. 27 97 5. 30 25 2. 0 41/35/31 51 1. 00 Capillary tube Æ12. 7 Flare connection Æ6. 35 Flare connection 49 R22 51 47 1. 26 98 0. 15 5. 35 5. 15 5. 75 1. 33 96 1. 24 98 220 V 3. 70
Cooling 240 V 3. 75
1. 28 95 5. 60 24
Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference
INDOOR UNIT
Outdoor (220 - 240 V) dB kg mm mm
48 0. 80
Refrigerant control
m m
RAS-13UKHP-E4
15* 6
1
RAS-13UKP-E4
Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter
OUTDOOR UNIT
mm mm mm kg
275 790 208 10 Finned tube Cross flow fan
Width Depth
m3/h m /h
3
630 520 430
650 550 490 20 Honeycomb woven filter with PP frame
RAS-13UAH-E4
630 520 430
m3/h W
RAS-13UA-E4
Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth
mm mm mm kg 37
550 780 270 34 Finned tube Propeller fan
m /h
3
2120
2200 42
2120
2200
2030 30
2150
W W
PH225X2C-4FT 1100 Fuse, Overload relay Automatic louver °C 15 ~ 43 -10 ~ 24 15 ~ 43
3
FILE NO. SVM-05001
MODEL
GR-232MF / RAS-10UAH-E4
RAS-10UKP-E4 / RAS-10UA-E4
ITEM Capacity 220 V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 47 4. 30 0. 93 95 2. 65
Cooling 240 V 2. 70 220 V 2. 95
Heating 240 V 3. 00 1Æ 220 - 240 50 0. 98 92 4. 27 0. 84 94 0. 15 3. 90 19 1. 2 39/33/26 49 0. 76 Capillary tube Æ9. 52 Flare connection Æ6. 35 Flare connection 47 R22 49 44 3. 77 3. 60 0. 86 91 0. 80 97 220 V 2. 65
Cooling 240 V 2. 70
0. 85 95 3. 58 16
Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference
INDOOR UNIT
Outdoor (220 - 240 V) dB kg mm mm
45 0. 68
Refrigerant control
m m
GR-232MF
10*1 5
RAS-10UKP-E4
Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter
OUTDOOR UNIT
mm mm mm kg
275 790 208 10 Finned tube Cross flow fan
Width Depth
m3/h m /h
3
570 460 340
610 520 400 20 Honeycomb woven filter with PP frame
RAS-10UAH-E4
610 460 340
m3/h W
RAS-10UA-E4
Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth
mm mm mm kg 32
550 780 270 31 Finned tube Propeller fan
m /h
3
1740
1850
1740 20
1850
1740
1850
W PH180X1C-4DZDN3 W
RM5510GNE94 750
Fuse, Overload relay Automatic louver °C 15 ~ 43 -10 ~ 24 15 ~ 43
-4-
FILE NO. SVM-05001
MODEL ITEM
Capacity kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 44 45 0. 60 Capillary tube mm mm 9. 52 Flare connection 6. 35 Flare connection m m 10*1 5 45 46 R-22 kg 0. 57 2. 69 2. 77 13 0. 8 38/32/26 44 45 44 45 2. 35 2. 40 0. 61 98 0. 68 97 0. 54 98 0. 59 96 0. 15 2. 55 2. 55 11 2. 55 2. 55 2. 00
RAS-07UKHP-E4/ RAS-07UAH-E4 Cooling
220V 240V 2. 05 2. 00
RAS-07UKP-E4/ RAS-07UA-E4 Cooling
220V 2. 10 1 220 - 240 50 0. 58 98 0. 62 96 240V 2. 15 2. 05 240V
RAS-07UKPX4/ RAS-07UAX4 Cooling
220V 2. 10 240V 2. 15
Heating
220V
0. 58 98
0. 62 96
Starting current Moisture removal Noise Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference
Outdoor (220-240V) dB Refrigerant
Refrigerant control
INDOOR UNIT
Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter m3/h m3/h m3/h W 570 460 340 Width Depth mm mm mm kg
RAS-07UKHP-E4
275 790 208 10 Finned tube
RAS-07UKP-E4
RAS-07UKPX4
Cross flow fan 610 490 400 20 Honeycomb woven filter with PP frame 570 460 340
OUTDOOR UNIT
Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 Model Output W m3/h W 1280 Width Depth mm mm mm kg
RAS-07UAH-E4
530 660 240 28 Finned tube Propeller fan 1360 1280 1360 20
RAS-07UA-E4
RAS-07UAX4
27
1280
1360
1280
1360
PH108X1C-4DZDN2 605 Fuse, Overload relay Automatic louver -10 ~ 24 15 ~ 43 21 ~ 43
5
FILE NO. [. . . ] Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. Installation in the following places may result in trouble. · A saline-place such as the coast. · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment.
Drain hose
Inside the room
Extension drain hose
Fig. 8-4-20
CAUTION
Arrange the drain pipe for proper drainage from the unit. Improper drainage can result in dew-dropping. This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan. Therefore, do not store the power cord and other parts at a height above the drain guide.
Wall Drain guide
Strong wind
Space for pipes
Fig. Cut the pipe with a pipe cutter.
Obliquity Roughness Warp
(Unit : N·m) Outer dia. (15 minutes for 20 meters) (assuming a pump capacity of 27 liters per minute. ) Then confirm that the compound pressure gauge reading is -101 kPa (-76 cmHg). Close the low pressure side valve handle of gauge manifold. Open fully the valve stem of the packed valves (both sides of Gas and Liquid). Remove the charging hose from the service port. Securely tighten the caps on the packed valves.
Compound pressure gauge -101 kPa ( -76 cmHg) Manifold valve Handle Lo Charge hose Connecting pipe Vacuum pump adapter for counter-flow prevention
Vacuum pump
<Packed valve handling precautions>
· ·
Open the valve stem all the way out; but do not try to open it beyond the stopper. Securely tighten the valve stem cap with torque in the following table: Gas side ( Æ12. 70 mm) Gas side (Æ9. 52 mm) Liquid side (Æ6. 35 mm) Service port 50 to 62 Nám (5. 0 to 6. 2 kgfám) 30 to 42 Nám (3. 0 to 4. 2 kgfám) 16 to 18 Nám (1. 6 to 1. 8 kgfám) 9 to 10 Nám (0. 9 to 1. 0 kgfám) Hexagonal wrench is required.
4m m
Fig. 8-5-8
Pressure gauge
Handle Hi (Keep full closed) Charge hose
Packed valve at gas side Service port (Valve core (Setting pin)) Packed valve at liquid side
Fig. Remove the valve cover from the outdoor unit. Connect the connecting cable to the terminal as identified with their respective matched numbers on the terminal block of indoor and outdoor unit. When connecting the connecting cable to the outdoor unit terminal, make a loop as shown in the installation diagram of indoor and outdoor unit, to prevent water coming in the outdoor unit. Insulate the unused cords (conductors) from any water coming in the outdoor unit. [. . . ] 13 14 15 16 17 18 19 20 21 22 23
Part No. 43T47333 43T63303 43T47014 43T41348 43T47324 43T49008 43T52310 43T00396 43T55304 43T55314 43T60322
Description BONNET, 12. 70 DIA FIXING PLATE VALVE CAPILLARY TUBE; 1. 7DIA COMPRESSOR (HP225X2C-4FT) BOLT COMPRESSOR (M6) CUSHION, RUBBER PACKED VALVE COVER ASSEMBLY UPPER CABINET ASSEMBLY MF CAPACITOR CAPACITOR, PLASTIC FILM TERMINAL-2P
- 86 -
FILE NO. Outdoor Unit (RAS-10UA-E4)
Location No. 01 02 03 04 05 06 07 08 09 10 11 12
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-232MF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-232MF will begin.