[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] m
To unit out line 240mm
Offset 85mm from the left side edge is the center of pipe hole
170 85
To unit out line 240mm
To unit out line 35mm
To unit out line 120mm
0 23 35 120
180
240
Indoor unit
(Side view)
(Top view) Indoor unit
45° 45°
Hook Pipe hole Indoor unit Thread Weight
Hook 7 Mounting screw
Pipe hole (Dia. 65mm)
1 Installation plate
75
°
Reception range
Reception range Remote controller Remote controller
Fig. 10-3-1
55
2m or more from floor
Anchor bolt holes
When the installation plate is directly mounted on the wall
1. Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out. To mount the installation plate on a concrete wall use anchor bolts. Drill the anchor bolt holes previous page. Install the installation plate horizontally and level.
10-3-3. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare a power source for the exclusive use of the air conditioner.
NOTE : · Wire type : More than 1. 5 mm² H07RN-F or 60245IEC66.
CAUTION CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage. This appliance can be connected to a main circuit breaker in either of the following two ways. Changing drain hose For left connection, left-bottom connection and rear-left connection's piping, it is necessary to relocate the drain hose and drain cap.
Stripping length of the connecting cable
Fig. 10-3-6
110mm 10mm
How to remove the drain cap
Earth line
Clip drain cap with needle-nose pliers, and pull out.
10mm 50mm
Fig. 10-3-7
NOTE : WIRE TYPE : More than 1. 0mm². (H07 RN-F or 60245 IEC 66).
How to remove the drain hose
The drain hose is secured in place by a screw. Remove the screw securing the drain hose, then pull out the drain hose.
Heat insulator
Drain hose
Fig. 10-3-10
57
Piping preparation
How to attach the drain cap
1. Insert hexagonal wrench (4 mm).
In case of bottom right or bottom left piping
· After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Slit
4 mm
Fig. Firmly insert drain cap.
Left-hand connection with piping
Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. When bending the connecting pipe, make sure to use a spring bender to avoid crushing the pipe.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. If applied, deterioration and drain leakage of the drain plug may occur.
Insert a hexagon wrench (Ø4mm)
Refer to the table below for the bending radius of each connection pipe.
Outer diameter 6. 35 mm Bending radius 30 mm 50 mm
Fig. [. . . ] Check that all the hooking claws are fixed to the specified positions.
101
No.
11
Part name
Procedure
Remarks
TE sensor (Outdoor heat exchanging temperature sensor) · Attachment With the leads pointing downward and the sensor leads pointing in the direction shown in the figure, install the sensor onto the straight pipe part of the condenser output pipe.
Detail C for RAS-18SAV-E
12
Detail C for RAS-22SAV-E
TS sensor (Suction pipe temperature sensor) · Attachment With its leads pointing downward, point the sensor in the direction of the packed valve, and install it onto the straight pipe part of the suction pipe. TD sensor (Discharge pipe temperature sensor) · Attachment With its leads pointed downward, install the sensor onto the vertical straight pipe part of the discharge pipe. TO sensor (Outside air temperature sensor) · Attachment Insert the outdoor air temperature sensor into the holder, and install the holder onto the heat exchanger.
13
14
Detail A TS sensor
Detail B TD sensor
Arrow D TO sensor
CAUTION During the installation work (and on its completion), take care not to damage the coverings of the sensor leads on the edges of the metal plates or other parts. It is dangerous for these coverings to be damaged since damage may cause electric shocks and/or a fire. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-892DEPF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.