User manual LG GR-A207CTB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-A207CTB. We hope that this LG GR-A207CTB user guide will be useful to you.

Lastmanuals help download the user guide LG GR-A207CTB.


Mode d'emploi LG GR-A207CTB
Download
Manual abstract: user guide LG GR-A207CTB

Detailed instructions for use are in the User's Guide.

[. . . ] WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PARTS RATING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERATING CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROL OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] outdoor header unit. 62 E18 -- -- 97, 99 Indoor unit Communication error between indoor header and follower units Corresponding unit only stops. E19 E19 00: No header unit 02: Two or more header units 96 I/F Outdoor header unit quantity error All stop E20 E20 01: Connection of outdoor of other line 02: Connection of indoor of other line -- 42 I/F Other line unit connected during automatic address All stop E23 E23 15 I/F Communication sending error between outdoor units All stop Regular communication between indoor header and follower units . · · · · Check wire of the remote controller. Check SW02 setup on the wall type P board. (Should be Bit 1: ON, Bit 2: OFF) · There are multiple outdoor header units in 1 line. · There is none of outdoor header unit in 1 line. The outdoor unit connected with communication wire between indoor and outdoor (U1. U2) is the outdoor header unit. · Check connection of communication line between indoor and outdoor. · Check outdoor P board(I/F) error. Separate the wire between lines according to automatic address setup method in "Address setup". · Check the power of outdoor unit. (Is the power turned on?) · Check connection of communication wire or disconnection between outdoor units. · Check the connector for communication on outdoor P board. · Resistance value of sensor is infinite or zero (Open/Short). · Resistance value of sensor is infinite or zero (Open/Short). · Resistance value of sensor is infinite or zero (Open/Short). · Check connection/wiring of TCJ sensor connector. · Check characteristics of TCJ sensor resistance value. · Check connection/wiring of TC2 sensor connector. · Check characteristics of TC2 sensor resistance value. · Check connection/wiring of TC1 sensor connector. · Check characteristics of TC1 sensor resistance value. · Check connection of TD1 sensor connector. · Check characteristics of TD1 sensor resistance value. · Check outdoor P board (I/F) error. [. . . ] Indoor Unit Model: MMK-AP0073H, MMK-AP0093H, MMK-AP0123H 207 236 225 223 204 237 206 218 Detail Drawi-ng A 242 203 240 241 202 212 213 214 224 215 A 235 222 201 238 208 220 211 219 234 217 232 209 210 Location No. 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 217 218 Part No. 43T22312 43T70313 43T20016 43T49010 43T83003 43T46029 43T19333 43T79313 43T66304 43T09439 43T49043 43T39026 43T39022 43T39023 43T80019 43T62031 43T39024 Description Bearing Ass'y Hose, Drain Fan Ass'y, Cross Flow Pipe, Shield Holder, Remote Controller Motor, PMV Holder, Sensor Cap, Drain Remote Controller, Wireless, WH-L11SE Grille Ass'y Holder, Pipe Band, Motor, Left Band, Motor, Right Up Band, Motor, Right Down Air Filter Cover, Terminal Drain Guide Location No. 219 220 222 223 224 225 232 233 234 235 236 237 238 240 241 242 205 233 Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-A207CTB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-A207CTB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag