Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-B207GTG. We hope that this LG GR-B207GTG user guide will be useful to you.
Lastmanuals help download the user guide LG GR-B207GTG.
Detailed instructions for use are in the User's Guide.
[. . . ] Remote controller
Name Wireless remote controller Model name Appearance
(Packed with the indoor unit) Application Function ·E Start / Stop ·E Changing mode ·E Temperature setting ·E flow changing (5 step) Air ·E Clock ·E Timer function - ON/OFF timer (10 min. step) - Everyday timer ·E High power mode ·E ECO mode (Sleep timer wtih ECO-logic) ·E One-touch pre-set memory ·E One-touch Auto (*1)
(Note. 1) Super MMS can not accept "AUTO" mode, Super HRM can accept "AUTO" mode.
1-3. Wiring Design
Model GR-B207GTG MMK-AP0092H MMK-AP0122H
Legend MCA MOCP
WH-H2UE
50Hz Voltage Min Max 198 264 198 264 198 264 Fan Motor kW FLA 0. 03 0. 20 0. 03 0. 21 0. 03 0. 22
FLA kW
Nominal Voltage (V-Ph-Hz) 230-1-50 230-1-50 230-1-50
Power Supply MCA MOCP 0. 24 15 0. 26 15 0. 27 15
: Minimum Circuit Amps : Maximum Overcurrent Protection (Amps)
: Full Load Amps : Fan Motor Rated Output (kW)
1-4. [. . . ] Accessories
Accessory parts name Wired remote controller Simple remote controller Wireless remote controller kit Central remote controller Weekly timer Model RBC-AMT21E RBC-AS21E TCB-AX21E TCB-SC642TLE RBC-AS21E Remarks with separeted reciever unit Max. 64 group / unit Use with RBC-AMT21WE
2. Technical Specifications
High Wall type (2 Series)
Model name Cooling / Heating capacity (Note 1) Power Supply
Electrical Characteristics
50Hz
MMK(kW) AP0072H 2. 2 / 2. 5 AP0092H 2. 8 / 3. 2 AP0122H 3. 6 / 4. 0
(Power exclusive for indoor is required. )
1 phase 50Hz 230V (220-240V) 0. 18 0. 018 0. 23 Moon white Moon white Moon white
Running current Power consumption Starting current Suction grille and side panel
(A) (kW) (A)
0. 17 0. 017 0. 22
0. 19 0. 019 0. 24
Appearance
Discharge grille Bottom surface
Outer dimension Total weight Heat exchanger
Height x Width x Depth
(mm) (kg)
275 x 790 x 208 11 Finned tube Non-flammable insulation Cross-flow fan
Soundproof/Heat-insulating material Fan Fan unit Standard air flow (High/Mid/Low) Motor Air filter Controller (Note 3) Gas side Connecting pipe Liquid side Drain port (mm) (mm) (Nominal dia. ) (dB(A)) 35-32-29 (m3/h)
480 / 420 /360
510 / 450 / 360 30
540 / 450 / 360
Standard filter attached (Simple filter)
(WH-H2UE, Packed with indoor unit)
Wireless remote controller 9. 5 6. 4
17 (Polyvinyl chloride tube) 36-33-29 37-33-29
Sound level (Note 2) (High / Mid / Low) Note 1 :
The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2. 5 m of branch piping connected with 0 meter height.
Note 2
:
The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.
Note 3 Note 4
: :
Wireless remote controller is packed with indoor unit. Wired remote controller (RBC-AMT21E, RBC-AS21E) can be also connected. Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB,
Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20C DB, Outdoor air temperature 7C DB/6C WB
2
3. Automatic controls for quick cooling and heating No remote controller sensor
OK OK OK
Hi-POWER FILTER RESET -
OK OK OK -
1. Automatic operation mode can not be accepted by heat pump system. If trainsmission is sent as auto mode, operation la mp and timer lamp of the indoor unit will light up with the beep as the notice. In this case, change the other operation mode to release the notice. ( Heat recovery system can accept automatic operation by using this wireless remote controller. ) 2. Group control by using the wired remote controller (WH-H2UE) is not available. If it is done, incorrect action or display disagreement may occur. [. . . ] Group control by using the wired remote controller (WH-H2UE) is not available. If it is done, incorrect action or display disagreement may occur. A wired remote controller is required for the group control. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-B207GTG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-B207GTG will begin.