User manual LG GR-L207DLZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-L207DLZ. We hope that this LG GR-L207DLZ user guide will be useful to you.

Lastmanuals help download the user guide LG GR-L207DLZ.


Mode d'emploi LG GR-L207DLZ
Download
Manual abstract: user guide LG GR-L207DLZ

Detailed instructions for use are in the User's Guide.

[. . . ] · Turn off the main power supply switch or breaker before attempting any electrical work. Failure to do so may cause electric shock. · Perform installation work properly according to this Installation Manual. Improper installation may result in electric shock or fire. [. . . ] Any modification may cause a malfunction, resulting in overheating or fire. CAUTION · Perform wiring correctly in accordance with specified the current capacity. Failure to do so may result in short-circuiting, overheating, or fire. · Connect the specified cables for the terminals securely to prevent external forces from affecting them. Failure to do so may result in disconnection, overheating, or fire. 1 Introduction nApplications/Functions/Specifications Applications/Functions/Specifications · Applications The Digital Input/Output Relay Interface is used to control air conditioners by interlocking them with electric lock signals and fire alarm signals, and to transmit air conditioner failures to other devices. · Functions The Digital Input/Output Relay Interface connects non-voltage contact signals, transmits their input status to the Touch Screen Controller, and outputs signals from the contacts (open collector) according to the command from the Touch Screen Controller. · Specifications Power supply Power consumption Operating temperature/ humidity Storage temperature Chassis material Dimensions Mass 220 - 240 V, AC 50/60 Hz 6. 5 W 0 to 40 °C, 10 to 90% RH -20 to +60 °C Galvanized sheet metal 0. 8t (no coating) 66(H) x 193(W) x 246(D) mm 1. 65 kg Digital input Input type Input points Input registance Input "ON" current Output type Output points Output current Output voltage External power supply for Input/Output Photo-coupler insulation 8 points 9 k ohm 1 mA Open collector 4 points Max. 35 mA (per point) Less than DC 24V DC 12 V, 120 mA Digital output External View 234 18 Grommet for power input 18 Grommet for Digital Inputs 103. 5 92. 5 (193) Grommet for RS485 53. 5 64. 5 220 18 18 246 Grommet for Digital Outputs 2 63. 6 66 Before Installation Check the following package contents. No. 1 2 3 4 Item DIGITAL INPUT/OUTPUT RELAY INTERFACE Installation Manual Screw Pin terminal Quantity 1 1 4 2 M4 x 12mm tapping screws Remarks Use the following wiring materials to connect signal lines and power lines. 1 Line Type For RS-485 Description 2-core shield wire Wire size 1. 25mm2, 500m max. (total length) Length Type Wire size 2-core wire, 0. 3mm2, 100m max. Length Type H07 RN-F or 245IEC66 Wire size 0. 75mm2, 50 m max. 2 For digital Input/Output connection For power 3 3 1 Installation Digital Input/Output Relay Interface Installation Method and Orientation There are five installation methods for this relay interface as shown below, surface mount or wall mount. Use the attached screws. No good REQUIREMENT Do not install the unit in any of the following places. No terminator resistor setting switch is provided on the Digital Input/Output Relay Interface. Load 1 Load 2 Load 3 Load 4 DIGITAL I/O INTERFACE DO1 DO2 DO3 DO4 GND +12V 7 3 SW4 Setting SW3 ON DI1 SW1 SW2 SW1 Address set switch 1-4 0, 5 - F Address Not used LED2 LED3 LED4 SW7 DI2 1234 LED5 SW2 SW3 SW4 SW7 LED1 LED2 LED3 LED4 LED5 LED14 LED17 Operating mode set switch (0 usually) Test switch (all OFF usually) Test switch Reset switch Power indicator RS-485 communication status indicator Not used Test indicator Test indicator Digital output indicator N LED1 L RS-485 DO1 LED17 LED16 LED15 LED14 DO2 DO3 DO4 GND +12V The following settings are necessary to use Digital Input/Output Relay Interfaces. · SW1 Address set switch When two or more Digital Input/Output Relay Interfaces are used, set a different address for each unit to avoid address duplication. Assign addresses in ascending order. AB DI8 DI7 DI6 DI5 DI4 DI3 CAUTION · Set relay interface addresses according to the air conditioner address table. · When the SW1 setting has been changed, push the reset switch SW7. · SW2 · SW3 · SW4 · SW7 Operation mode set switch These switches are not used during normal Test switch operation. Test switch Reset switch When performing address setting with SW1, push this reset switch after address setting to read the set value. 8 4 Trial Operation Check Before starting trial operation Turn on the power of the Digital Input/Output Relay Interface after all cable connections and settings are completed. Turn on power of the air conditioning control system. Trial operation · Confirming external input connection In the test mode, when the external inputs connected to the input terminals DI-1 to DI-8 are ON, the respective LEDs will goes on so you can confirm the connection. Confirming procedure: Set the operation mode switch SW2 to "3", and push the reset switch SW7 to enter the test mode. Unless SW4 is pushed, the respective input status of DI-1 to DI-4 is indicated by LED2 to LED5. When SW4 is pushed, the respective input status of DI-5 to DI-8 is indicated by LED2 to LED5. (*) To return to the normal operation, reset SW2 to "zero (0)" and push SW7. SW4 OFF SW4 ON LED2 Displays DI-1 input status. [. . . ] When SW4 is pushed, the respective input status of DI-5 to DI-8 is indicated by LED2 to LED5. (*) To return to the normal operation, reset SW2 to "zero (0)" and push SW7. SW4 OFF SW4 ON LED2 Displays DI-1 input status. Input ON: LED lights Input OFF: LED turns off LED4 Displays DI-3 input status. Displays DI-8 input status. · Checking external output connection In the test mode, you can set output terminals DO1 to DO4 to ON or OFF with the test switch. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-L207DLZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-L207DLZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag