Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-L207QLR. We hope that this LG GR-L207QLR user guide will be useful to you.
Lastmanuals help download the user guide LG GR-L207QLR.
Detailed instructions for use are in the User's Guide.
[. . . ] Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Connect BLUE colored core to plug terminal marked letter "N". Connect GREEN AND YELLOW colored core to plug terminal marked Earth Symbol " ". <How to remove the front cabinet>
4 4 12 12 3 Vertical air flow louver.
Screw Earth line Screw
Fig. 8-4-7 How to open the screw cap <Stripping length of power cord>
30mm 10mm L N
· Place your finger on the lower part and push up to open the screw cap. (1) Open the screw caps and remove the two screws securing the front cabinet. (3) Open the vertical airflow louver horizontally by hand. (4) Slightly open the lower part of the front cabinet then pull the upper part of the front cabinet toward you to remove it from the rear plate.
10mm 40mm
Earth line
NOTE : · Use standard wire only. · Wire type: More than H05-RNF Fig. 8-4-8
28
<How to connect the connecting cable> Wiring of the connecting cable can be carried out without removing of the front panel. Disengage the support arm located in the upper center while pushing its handle leftwards, and then remove the front panel toward you. (2) Remove the terminal cover and cord clamp. (Use polyethylene foam as insulating material. ) · When bending a pipe, carefully do it not to crush it.
30
8-4-5. Indoor Unit Installation
(1) Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. (2) Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. (3) While pressing the indoor unit onto the wall by the lower part, hook it up on the installation plate by the lower part. Pull the indoor unit toward you by the lower part to confirm that it is firmly hooked up on the installation plate.
(1)
8-4-6. Drainage
(1) Run the drain hose sloping downwards. NOTE : · Hole should be made at a slight downwrd slant to the outdoor side.
Do not rise the drain hose. Do not form the drain hose into the wared shape.
50 mm or more
Do not put the drain hose end into water.
Do not put the drain hose end in the drainage ditch.
Hook here 1 Installation plate
(2)
Fig. 8-4-17 (2) Put water in the drain pan and make sure that the water is drained outdoors. (3) When connecting extension drain hose, insulate the connecting part of extension drain hose with 5 shield pipe.
5 Shield pipe
Hook
Push
Fig. 8-4-15 · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up by the specified parts.
Drain hose Inside the room
Extension drain hose
Fig. [. . . ] Microcomputer (GR-L207QLR, RAS-10SKHX)
No. Part name Common procedure Procedure 1) Turn the power supply off to stop the operation of air-conditioner, and disconnect the power cord from the AC supply. (4 x 14 ) 3) Remove the electrical part base. 3) Disconnect the terminal blocks connected with the connecting cable, and the power cord from base Eparts by removing the screws. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-L207QLR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-L207QLR will begin.