User manual LG GR-L247MGZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG GR-L247MGZ. We hope that this LG GR-L247MGZ user guide will be useful to you.

Lastmanuals help download the user guide LG GR-L247MGZ.


Mode d'emploi LG GR-L247MGZ
Download
Manual abstract: user guide LG GR-L247MGZ

Detailed instructions for use are in the User's Guide.

[. . . ] · Do not install the appliance in rooms containing gas, oil or sulphur. · Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (eg aerosol cans). · Do not rest heavy or hot objects on top of the appliance. · Clean the air filter at least once a week. [. . . ] · Make sure the air exhaust hose is unobstructed. C Keep the air hoses as short and free of curves as possible to avoid constrictions. 16 Pre p a r i n g f o r u s e AIR-CONDITIONING WITH INSTALLATION If required, your appliance can also be installed semi-permanently (Fig. · Fit the wall flange accessory ded in the hole. · Fit the air exhaust hose vant hose 7 the appliance (see fig. · Screw the wall mounting accessory hose 13 14 13 11 GB provi- in the rele- located on the rear side of al tubo uscita aria 12 to the air exhaust or, if necessary, unscrew the 12 from the air exhaust hose and adapter 14 replace it with the wall installation terminal (fig. F). 30 cm 30 cm D Proceed as follows: · Drill a hole (ø134mm) in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure E. 1 2 F · Insert the other end of the hose 12 the flange 11 on as shown in fig. G. MAX100 cm 134 MIN 35 cm in the window pane in the wooden kickboard of a French window E in the wall: you are recommended to insulate the section of wall using suitable insulation. G When the hose 12 is not fitted, the hole can be closed with the flange cap 11 . When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation. Keep the air hoses as short and free of curves as possible to avoid constrictions. 17 Control panel THE CONTROL PANEL S Q O P N I T L M H G A B C R D E F DESCRIPTION OF THE CONTROL PANEL A ON/OFF button B MODE selection button Air conditioning, dehumidifying, fan. C Fan speed selection button (MAX/MED/MIN) D Timer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display (Displays the temperature values set, room temperature and the programmed operating time) H Timer in operation indicator light I/L/M Fan speed lights N Fan mode light O Air-conditioning mode light P Dehumidifying mode light Q Alarm light R Remote control signal receiver S Light: displays room temperature T Light: displays set temperature Never turn the air conditioner off by unplugging from the mains. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation. The indicator light (H) flashes until the appliance starts up. You can set the appliance to come on with a delay of up to 12 hours. To cancel the timer programme, press the timer button (D) again. How to programme delayed shut down · Delayed shut down can be programmed in any operating mode (air conditioning / fan/ dehumidifying). · Use the + (E) or - (F) buttons to set the number of hours delay before the appliance goes off. The time increases or decreases in steps of one hour. The light (H) flashes until the appliance turns off as programmed. At the set time, the air conditioner shuts down and remains in standby. To cancel the timer programme, press the timer button (D) again. Light (H) stops flashing. 20 Using the remote control unit (some models only) MODELS WITH REMOTE CONTROL · Point the remote control at the receiver on the air-conditioner. The remote control must be no more than 5 metres away from the appliance (without obstacles between the remote control and the receiver). [. . . ] To clean the filters, remove the filter as shown in figure H. Use a vacuum cleaner to remove the dust collected on the filter. If it is very dirty, immerse in warm water and rinse a number of times. The water should never be hotter than 40°C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG GR-L247MGZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG GR-L247MGZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag