User manual LG LA120HP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LA120HP. We hope that this LG LA120HP user guide will be useful to you.

Lastmanuals help download the user guide LG LA120HP.


Mode d'emploi LG LA120HP
Download
Manual abstract: user guide LG LA120HP

Detailed instructions for use are in the User's Guide.

[. . . ] PARTS REPLACEMENT 10-1 Indoor Unit 10-2 Outdoor Unit (RAS-24GAH-ES2, RAS-24GA-ES2) 10-3 Outdoor Unit (RAS-18GAH-ES2, LA120HP) 11. EXPLODED VIEWS AND PARTS LIST 11-1 11-2 11-3 11-4 11-5 11-6 Indoor Unit (E - Parts Assy) Indoor Unit Outdoor Unit (RAS-24GAH-ES2) Outdoor Unit (RAS-18GAH-ES2) Outdoor Unit (RAS-24GA-ES2) Outdoor Unit (LA120HP) · This air conditioner is charged with HFC (R410A) that doesn't deplete the Ozone layer. · This air conditioner requires special installation for the refrigerant R410A. -2- FILE NO. SPECIFICATIONS RAS-24GKHP-ES2 MODEL ITEM Capacity kW Phase Power source Power consumption Power factor Running current Starting current Moisture removal Noise Refrigerant Refrigerant control Gas side size Connection type Liquid side size Interconnection pipe Connection type Maximum length (One way) Maximum height difference INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Note *1 Chargeless pipe *2 Maximum pipe °C 15 ~ 43 -10 ~ 24 Model Output W IOL, Td Sensor m3/h W 2400 2550 2400 2550 42 PA290X3CS-4MU1 2160 IOL 21 ~ 43 IOL, Td Sensor Automatic louver 15 ~ 43 -10 ~ 24 21 ~ 43 2400 Width Depth mm mm mm kg 56 RAS-24GAH-ES2 715 780 290 52 Finned tube Propeller fan 2550 2350 2450 2350 2450 42 PA225X2CS-4KU1 1500 IOL 2120 2200 Medium fan Low fan m /h m3/h m3/h W RAS-24GA-ES2 3 RAS-24GKP-ES2 RAS-24GA-ES2 Cooling 220V 6. 80 240V 6. 85 RAS-18GKHP-ES2 RAS-18GAH-ES2 Cooling Heating 220V 240V 220V 240V 5. 00 5. 05 5. 45 5. 55 1 RAS-18GKP-ES2 LA120HP Cooling 220V 5. 30 240V 5. 35 RAS-24GAH-ES2 Cooling Heating 220V 240V 220V 240V 6. 30 6. 30 6. 80 6. 90 V Hz W % A Indoor/Outdoor A lit/h Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount kg 1. 90 1. 70 dB dB 56-57 2430 2510 2400 2480 98 85 99 88 220V 240V 220V 240V 0. 3/ 0. 3/ 0. 3/ 0. 3/ 11. 0 11. 23 10. 7 11. 45 54 2. 5 45/43/41/39/37 57-58 56-57 2560 99 220V 220 - 240 50 2690 92 240V 1850 1900 1678 1748 98 0. 3/ 8. 3 97 94 92 220V 240V 220V 240V 0. 3/ 0. 3/ 0. 3/ 7. 9 7. 8 36 2. 0 44/42/39/37/35 52-53 R410A 1. 15 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 15*1 25*2 10 RAS-24GKHP-ES2 RAS-24GKP-ES2 298 998 220 13 Finned tube Cross flow fan 900 750 625 900 800 667 900 750 625 30 Honeycomb woven filter with PP frame RAS-18GAH-ES2 550 780 290 44 LA120HP 550 780 290 39 900 667 543 900 708 584 900 667 543 RAS-18GKHP-ES2 20*2 8 RAS-18GKP-ES2 1. 26 53-54 51-52 7. 6 1860 97 220V 0. 3/8. 4 33 2. 0 1960 96 240V 0. 3/8. 2 0. 3/11. 75 0. 3/12. 20 54 2. 7 mm mm m m mm mm mm kg Width Depth -3- FILE NO. [. . . ] · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment. R410A tool used 0 to 0. 5 0 to 0. 5 Conventional tool used 1. 0 to 1. 5 1. 0 to 1. 5 Imperial (wing nut type, conventional tool) Outer dia. of copper pipe 6. 35 12. 70 R410A 1. 5 to 2. 0 2. 0 to 2. 5 <Tightening connection> Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure. Strong wind CAUTION · Do not apply excess torque. · Otherwise, the nut may crack depending on the conditions. Fig. of copper pipe 6. 35 mm 9. 52 mm 12. 70 mm Tightening torque 16 to 18 (1. 6 to 1. 8 kgf·m) 30 to 42 (3. 0 to 4. 2 kgf·m) 50 to 62 (5. 0 to 6. 2 kgf·m) AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of the vacuum pump. <Using a vacuum pump> Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. (If oil inside of the vacuum pump enters into the air conditioner, which use R410A, refrigeration cycle trouble may result. ) 1. Connect the charge hose from the manifold valve to the service port of the gas side packed valve. Connect the charge hose to the port of the vacuum pump. · Securely tighten the valve stem cap with torque in the following table: Gas side (12. 70 mm) Liquid side (6. 35 mm) Service port 50 to 62 N·m (5. 0 to 6. 2 kgf·m) 16 to 18 N·m (1. 6 to 1. 8 kgf·m) 9 to 10 N·m (0. 9 to 1. 0 kgf·m) L N 1 2 3 Terminal screw Cord clamp Earth line Screw Cord clamp Hexagonal wrench is required. 4m m Power supply cord Connecting cable LN 10 12 3 10 10 70 70 10 80 60 Fig. 8-5-7 Power supply cord Earth line Connecting cable Fig. 8-5-8 Model Power s ource Maximum running current Plug s o c k e t & f u s e r a t i n g Power cord 24 Class 18 Class 50 Hz, 220 240 V Single phase 18A 20A 16A 20A 2 4 mm (H07R N-F or 245 IE C 66) or 3. 5 mm2 (AWG -12) CAUTION · Wrong wiring connection may cause some electrical parts burn out. · Be sure to comply with local codes on running the wire from indoor unit to outdoor unit (size of wire and wiring method etc). · Every wire must be connected firmly. NOTE: Connecting cable · Wire type: More than 1. 5 mm2 (H07RN-F or 245 IEC66) or 1. 3 mm2 (AWG-16) - 44 - FILE NO. How to Set Remote Control Selector Switch When two indoor units as installed in seperated rooms, there is no need to change the selector switch. <Remote control selector switch> · When two indoor units are installed in the same room or the adjacent two rooms, they may be controlled simultaneously with a single remote control. To prevent this, set either unit and its remote control to B setting. (Both units are set to A setting before shipment. ) · The remote control signal is not recived when the indoor unit setting is different from the remote control one. Set the remote control selector switch with the remote control [B] is indicated on the liquid crystal display when setting remote control selector switch to B. [. . . ] Indoor Unit (E-Parts Assy) 413 411 407 Location No. 43T60002 43T50004 43T50314 43T69559 43T62003 Description TERMINAL BLOCK; 3P SENSOR; HEAT EXCHANGER SENSOR;THERMOSTAT PC BOARD ASSY ; WRS-LED CORD CLAMP Location No. 43T69527 43T69528 43T69529 43T69530 43T63310 Description PC BOARD (RAS-24GKHP) PC BOARD (RAS-24GKP) PC BOARD (RAS-18GKHP) PC BOARD (RAS-18GKP) SENSOR HOLDER - 70 - FILE NO. Indoor Unit 221 229 230 201 203 202 227 208 217 219 213 228 222 220 215 214 232 218 209 226 216 211 231 224 210 212 223 207 234 235 Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LA120HP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LA120HP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag