[. . . ] s Be sure to read before installing the air conditioner. s Be sure to observe the cautions specified here as they include important items related to safety. s Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. [. . . ] Cut the cable 4. 9ft(1. 5m) longer than the pipe length.
Copper pipe
90°
Slanted Uneven Rough
Removing burrs
1. Completely remove all burrs from the cut cross section of pipe/tube. Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.
Point down
Pipe Reamer
Putting nut on
· Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal. (not possible to put them on after flaring work)
Flare nut
Copper tube
Flaring work
1. Firmly hold copper pipe in a die in the dimension shown in the table below. Carry out flaring work with the flaring tool.
Outside diameter mm inch Ø6. 35 1/4 Ø9. 52 3/8 Ø12. 7 1/2 Ø15. 88 5/8 Ø19. 05 3/4 A mm 1. 1~1. 3 1. 5~1. 7 1. 6~1. 8 1. 6~1. 8 1. 9~2. 1
Handle Bar Yoke Cone Copper pipe Clamp handle Red arrow mark
Bar
"A"
Installation Manual 17
Installation
Check
1. Compare the flared work with the figure by. If a flared section is defective, cut it off and do flaring work again.
Smooth all round Inside is shiny without scratches
= Improper flaring =
Even length all round
Inclined Surface Cracked Uneven damaged thickness
Connecting the Piping
Indoor
Preparing the indoor unit's piping and drain hose for installation through the wall. Route the indoor tubing and the drain hose in the direction of rear left or right
Drain hose
2. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Ground the unit in accordance with local codes. Be sure to size each wire allowing several inches longer than the required length for wiring. Use lock nuts to secure the conduit tubes.
NOTICE
Wiring Diagram
Indoor Unit Terminal (4P) 1 2 3 4
Connecting cable(Low voltage) b
Outdoor Unit Terminal (6P) 1 2 3 4 L1* 5 L2 6 Power supply a
G
To branch circuit Ground
* L1 is neutral for 115V models.
NOTICE
1.
shows field wiring.
Connector trade size for this unit is 1/2"(12. 7mm). Refer to "How to connect wiring to the terminals" for instructions on connecting depending on the wire type you are using.
2. Separately wire the high and low voltage line. Use heat-proof electrical wiring capable of withstanding temperatures up to 167°F(75°C). Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit. (For example, Type SJO-WA)
Outdoor unit
Terminal block
WARNING: · Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc). · Every wire must be connected firmly. · No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.
Over 5mm (2")
Conduit panel Connecting cable Power supply cord
Cover control
Power Supply
Model 18K Power source AWG(MIN) Fuse or breaker Capacity 18 20A
1Ø, 208/230V 14
22 Room Air Conditioner
Installation
Connection method of the connecting cable(Example)
1. Make a hole appropriate for the passage of connection cable through on cap by tool. [. . . ] Length Elevation length Refrigerant m(ft) B m(ft) A m(ft) g/m(oz/ft) 7. 5(25) 7. 5(25) 15(49) 20(0. 22) 7. 5(25) 7. 5(25) 15(49) 20(0. 22) 7. 5(25) 15(49) 7. 5(25) 15(49) 7. 5(25) 15(49) 30(98) 20(0. 22) 30(98) 20g(0. 22) 30(98) 30g(0. 32)
ENGLISH
Suction Evap
3/8"(1/2") 1/4" 3/8"(1/2") 1/4" 1/2" 5/8" 5/8" 1/4" 1/4" 1/4"
Example: A 30ft line set is used
5 additional ft X 0. 22 ounce per foot= add 1. 1 ounces of R-410A
Important:
If you are ever uncertain of the unit charge, reclaim, evacuate and weigh in the correct charge using the unit nameplate charge adjusting for line sets longer or shorter than 7. 5m(25ft).
Confirm the refrigerant R-410A. Use manifold gauge and hose for R-410A.
Installation Manual 29
Installation
Panel Front Assembly
1. First, Check the side cover assembly exactly, and fix the power cord in the bottom groove of cover side left.
2. Assemble connecting lead wire with controller, fix the upper part of panel front, and match the lower part of panel front.
Panel Front Connector
3. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LA180CP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.