User manual LG LA181CNW.ANCAEUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LA181CNW.ANCAEUS. We hope that this LG LA181CNW.ANCAEUS user guide will be useful to you.

Lastmanuals help download the user guide LG LA181CNW.ANCAEUS.


Mode d'emploi LG LA181CNW.ANCAEUS
Download
Manual abstract: user guide LG LA181CNW.ANCAEUS

Detailed instructions for use are in the User's Guide.

[. . . ] This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. I Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. I Installation Do not use damaged power cords, plugs, or a loose socket. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. [. . . ] length A m(ft) 15(49) 15(49) 15(49) 30(98) 15(49) 15(49) Additional Refrigerant g/m(oz/ft) 20(0. 22) 20(0. 22) 20(0. 22) 20(0. 22) 20(0. 22) 20(0. 22) Example: A 30ft line set is used 5 additional ft X 0. 22 ounce per foot= add 1. 1 ounces of R-410A Important: If you are ever uncertain of the unit charge, reclaim, evacuate and weigh in the correct charge using the unit nameplate charge adjusting for line sets longer or shorter than 7. 5m(25ft). Confirm the refrigerant R-410A. Use manifold gauge and hose for R-410A. Service Manual 31 Test Running 1. Check that all tubing and wiring have been properly connected. Check that the gas and liquid side service valves are fully open. Measure the temperature of the intake and discharge of air. Ensure the difference between the intake temperature and the discharge is more than 46. 4°F(8°C) (Cooling) or (Heating). Intake temperature Prepare remote control 1. Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (­) of battery are installed correctly. Reattach the cover by pushing it back into position. NOTE: · Use 2 AAA(1. 5volt) batteries. · Remove the batteries from the remote control if the system is not going to be used for a long time. Discharge air Discharge temperature 4. · When it reaches 0. 5°C above the setting temp, they start to operate again. Compressor ON Temp Setting Temp+0. 5°C Compressor OFF Temp Setting Temp-0. 5°C · While in compressor running, operating with the airflow speed set by the remote control. While in compressor not running, operating with the low airflow speed regardless of the setting. I Healthy Dehumidification Mode · When the dehumidification operation input by the remote control is received, the intake air temperature is detected and the setting temp is automatically set according to the intake air temperature. 26°C Intake Air Temp 25°C 24°C Intake Air Temp<26°C Intake Air Temp-1°C 18°C Intake Air Temp<24°C Intake Air Temp-0. 5°C Intake Air Temp<18°C 18°C Service Manual 33 Operation · While in compressor off, the indoor fan repeats low airflow speed and pause. · While the intake air temp is between compressor on temp. and compressor off temp. , 10-min dehumidification operation and 4-min compressor off repeat. Setting Temp+0. 5°C Compressor OFF Temp. Setting Temp-0. 5°C · In 10-min dehumidification operation, the indoor fan operates with the low airflow speed. I Heating Mode Operation · When the intake air temp reaches +3°C above the setting temp, the compressor is turned off. When reaches the setting temp, the compressor is turned on. Setting Temp. +3°C · While in compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C, when above 28°C , it operates with the low or setting airflow speed. [. . . ] · The operation with the remote controller, forced and test one do not operate. · The operation with the remote controller, forced and test one do not operate. · The operation with the remote controller, forced and test one do not operate. · The Indoor Fan does not operate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LA181CNW.ANCAEUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LA181CNW.ANCAEUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag