Detailed instructions for use are in the User's Guide.

[. . . ] Example) Equivalent length corresponded to farthest piping L Equivalent length corresponded to farthest piping after 1st branching Li L4 e Y-shape branch joint l f m g H2 H2 n A *1 H2 Allowable value Total extension of pipe (Liquid pipe, real length) Furthest piping length L (*1) Piping Length Real length Equivalent length 150 m 65 m 80 m 50 m 15 m 15 m 2 m or more below 10 m 30 m 20 m 15 m Piping section L1 + L2 + L3 + L4 + a + b + c + d + e + f + g + h + I + j + k+ l + m + n L1 + L3 + L4 + g + n L1 L3 + L4 + g + n a + h, b + i, c + j, d + k, e + l, f + m. g + n h, i, j, k, l, m, n ------ ------ ------ Max. equivalent length of main pipe Equivalent length of furthest piping from 1st branching Li (*1) Max. real length of indoor unit connecting pipe Real length between PMV KIT and indoor unit Height between indoor and outdoor units H1 Upper outdoor unit Lower outdoor unit Height Difference Height between indoor unit and PMV kit H2 *1 : Furthest indoor unit from 1st branch to be named "A". Note) Do not connect two or more indoor units to one PMV Kit. [. . . ] Indoor/outdoor communication line is not correctly connected to the outdoor unit. (Indoor/outdoor cannot communicate before address setup. ) There is none of outdoor terminator resistor, or there are two or more resistances. (Before address setup) E20-01 Address setup is performed with connecting indoor/outdoor communication line. ON 12 Remote controller status No response Countermeasures Set up addresses. (In order of indoor ® outdoor) Correct wiring. Check SW30 bit 2 of the outdoor unit. No connection between multiple refrigerant lines: SW30 bit 2 0N. Connection between multiple refrigerant lines: SW30 bit 2 of the connected outdoor unit is turned on only in one line. Correct wiring. SW30 Address setup is performed under condition of connecting between multiple refrigerant lines. 3 There is no display of a check code on 7-segment display on the interface P. C. board of the outdoor unit though there is indoor unit which does not accept the operation from the remote controller. 7-segment display of outdoor unit None Cause Communication line is not connected between indoor and outdoor. (Unit which does not response to remote controller) The power of the header unit of the group is not turned on in indoor group control. (Unit which does not response to remote controller) Group address is set up to follower unit in the individual control. (Unit which does not response to remote controller) Modify wiring. Push the temperature setup / buttons to select the item number (Item code) to be monitored. For displayed codes, refer to the table below. Push UNIT button to change the item to one to be monitored. Then monitor the indoor unit and sensor temperature or operation status in the corresponding refrigerant line. Pushing TEST CODE No. UNIT No. TEMP. ON / OFF 4 1 TIMER SET TIME FILTER RESET TEST SET CL FAN SWING/FIX UNIT MODE VENT 2 3 Operation procedure button returns the display to the normal display. 1® 2® 3® 4 Returns to the normal display Item code 00 Indoor unit data (NOTE 2) Data name Room temp (During control) Room temp (Remote controller) Indoor suction temp (TA) Indoor coil temp (TCJ) Indoor coil temp (TC2) Indoor coil temp (TC1) Indoor discharge temp (Tf) (Note 1) Indoor PMV opening No. of connected indoor units Total HP of connected indoor units No. of connected indoor units Total HP of outdoor units Unit °C °C °C °C °C °C °C pulse unit HP unit HP Display format Item code 10 (11) Data name Compressor 1 discharge temp (Td1) Compressor 2 discharge temp (Td2) High-pressure sensor detention pressure (Pd) Low-pressure sensor detention pressure (Ps) Suction temp (TS) Outdoor heat exchanger temp (TE) Temp at liquid side (TL) Outside ambient temp (TO) Low-pressure saturation temp (TU) Compressor 1 current (I1) Compressor 2 current (I2) PMV1 + 2 opening Compressor 1, 2 ON/OFF Outdoor fan mode Outdoor unit HP Unit °C °C MPa MPa °C °C °C °C °C A A pulse -- -- HP Display format ×1 ×1 × 100 × 100 ×1 ×1 ×1 ×1 ×1 × 10 × 10 × 1/10 (Note 3) 0 to 31 ×1 01 02 03 04 05 06 08 0A ×1 ×1 ×1 ×1 ×1 × 1/10 Outdoor unit individual data (NOTE 4, 5) 12 13 14 15 16 17 18 19 (1A) 1b 1d 1E System data 0b 0C 0d × 10 × 10 1F (Note 1) Only a part of indoor unit types is installed with the discharge temperature sensor. This temperature is not displayed for other types. (Note 2) When the units are connected to a group, data of the header indoor unit only can be displayed. (Note 4) The item codes are described as the example of the header unit. (Note 5) The upper digit of an item code represents the outdoor unit number. 18 Confirmation of indoor unit address and position by using the remote controller Confirmation of indoor unit address and position by using the remote controller [Confirmation of indoor unit address and the position] 1. [. . . ] 1 to 9 unit Indoor individual start/stop (ON/OFF) function 8 Pulse Motor Valve (PMV) Forced Open/Close Function in Indoor Unit This function is provided to fully open or close forcibly the PMV for 2 minutes in all indoor units, using the switch operation on the interface P board of the outdoor unit. This function is also used to open the PMV fully when turning off the power and executing an operation, for example, vacuuming. Operation [Open fully] Set the switch SW01 on the interface P board of the outdoor unit to [2], SW02 to [3], SW03 to [1] and push SW04 for . C. (Display shown on 7-segment display for 2 minutes as follows. ) [P ] [ FF] [Close fully] Set the switch on the interface P board of the outdoor unit SW01 to [2], SW02 to [3], SW03 to [1] and push SW05 for . C. (Display shown on 7-segment display for one minute as follows. ) [P ] [ 00] [Clear] After 2 minutes (1 minutes for "Close fully") have passed when setup has finished, the PMV automatically returns to the normal operation. 29 9 Continued Pulse Motor Valve (PMV) Forced Open Fully/Close fully Function in Outdoor Unit This function is provided to fully open or close fully the PMV used in the outdoor unit for 2 minutes. [Open fully] Short-circuit CN30 on the interface P board of the . C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LB-E6085BS1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LB-E6085BS1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag