Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LM-V535A. We hope that this LG LM-V535A user guide will be useful to you.
Lastmanuals help download the user guide LG LM-V535A.
Detailed instructions for use are in the User's Guide.
[. . . ] Purging the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the Refrigerant Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cutting/Flaring the Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performing Leak Test & Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (Not touchable by the users) Rigid wall without vibration. Where it is not exposed to direct sunshine. Where the air filter can be removed and cleaned easily.
As a rule, the unit cannot be installed at a height of less than 8. 3ft(2. 5 m). It is possible to install the unit at a height of between 7. 3~8. 3ft(2. 2~2. 5m)
from the ground, if the unit has a duct with a well defined length (11. 81inch(300mm) or more) to avoid fan motor blower contact.
Space Requirements for Indoor Unit
AVXC4/ND4H
(1500
59inch
more mm) or
59 i
nc h( 1
50 0m
m
)
or mo re
59
in c
h(
15
00
m
m
)
or mo re
59inch
(1500
or mor mm)
e
E-6
AVXC4_IM_E_31758_1. 13. 10. indd 6
2010-1-13 16:59:41
Dimension of the indoor unit
AVXC4/ND4H
Unit : inch(mm)
37. 40''(950) 33. 86''~35. 04''(860~890) Ceiling opening 27. 52''(699) Suspension position
5
6
Adjustable
AVXC4052/072 ND052/0724H
21. 65'' (550) 28. 19''(716)
2. 24'' (57)
33. 07''(840) 0. 98'' 10. 24''(260) 0. 98'' (25) 11. 42''(290) (25) 3. 94''(100) 3. 15''(80)
2. 24'' (57)
8. 58''(218)
6. 54''(166)
9. 06''(230)
1. 61'' (41)
12. 67''(322)
9. 53''(242) 9. 69''(246) 12. 01''(305)
Branch duct connection
AVXC4100/110/145 ND100/110/1454H
21. 65''(550) Adjustable
3
33. 07''(840) 2. 24'' (57)
2. 24'' (57)
2. 24'' (57) 6. 22''(158) 5. 43''(138) 2. 68''(68)
33. 07''(840) 0. 98'' 10. 24''(260) 0. 98'' (25) 11. 42''(290) (25)
2. 24'' (57)
29. 49''(749) 11. 73''(298)
12. 20''(310)
1. 61'' (41)
2. 52''(64) 6. 30''(160) 7. 48''(190)
12. 67''(322)
4
1
2
Branch duct connection
No.
Name
Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grille Air suction grille
Description
052 : ø1/4"(6. 35) 072/100/110/145 : ø3/8"(9. 52) 052 : ø1/2"(12. 70) 072/100/110/145 : ø5/8"(15. 88) VP25 (OD ø11/4"(32), ID ø1"(25)) E-7
AVXC4_IM_E_31758_1. 13. 10. indd 7
98. 43''(2500)
9. 53''(242) 9. 69''(246) 12. 01''(305)
or more required space
8. 19''(208)
7. 87''(200)
98. 43'' (2500)
8. 19''(208)
30. 16''(766) Suspension position 33. 86''~35. 04''(860~890) Ceiling opening
37. 40"(950)
2010-1-14 14:05:42
ENGLISH
Indoor Unit Installation
It is recommended to install the Y-joint before installing the indoor unit.
1
Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit.
Note
Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity. For this reason, before drilling the holes maintain the correct dimensions between the markings.
Concrete
Insert
2
Insert bolt anchors, use existing ceiling supports or construct a suitable support as shown in figure.
Hole in anchor Hole in plug
Suspension bolt(3/8" or M10) Ceiling support
3
Install the suspension bolts depending on the ceiling type. Ensure that the ceiling is strong enough to support the weight of the indoor unit. Before hanging the unit, test the strength of each attached suspension bolt. If the length of suspension bolt is more than 4. 94ft(1. 5m), it is required to prevent vibration. If this is not possible, create an opening on the false ceiling in order to be able to use it to perform the required operations on the indoor unit.
E-8
AVXC4Pipe size
(inch)
Minimum thickness of insulation (inch)
PE foam 0. 51 0. 98 EPDM foam 0. 39 0. 75
Remarks
If you install the pipe underground, at the seaside, a spa or on the lake, use 1 grade thicker one according to the pipe size.
Ø0. 25~Ø0. 63 -
Refrigerant pipe before EEV kit and MCU or without EEV kit and MCU
Insulation Insulation
You can contact the gas side and liquid side pipes but the pipes should not be pressed. When contacting the gas side and gas side pipe, use 1 grade thicker
Liquid pipe Gas pipe
insulator. Refrigerant pipe after EEV kit and MCU
0. 39inch (10mm)
0. 39inch (10mm)
0. 39inch (10mm)
Install the gas side and liquid side pipes, leave 0. 39inch(10mm) of space. When contacting the gas side and liquid side pipe, use 1 grade
thicker insulator.
Gas pipe
Liquid pipe
Install the insulation not to get wider and use the adhesives
on the connection part of it to prevent moisture from entering.
Wind the refrigerant pipe with insulation tape if it is exposed to
outside sunlight.
Install the refrigerant pipe respecting that the insulation does not
get thinner on the bent part or hanger of pipe.
Add the additional insulation if the insulation plate gets thinner.
Hanger
Additional insulation
a a×3
Refrigerant pipe insulation
E-14
AVXC4_IM_E_31758_1. 13. 10. indd 14
2010-1-13 17:00:09
Drain pipe and Drain Hose Installation
ENGLISH
Drainpipe Flexible hose AVXC4/ ND4H Drain hose port
Care must be taken when installing the drainpipe and drain hose for the indoor unit so that condensate water is drained correctly outside.
1
Fix the flexible hose to the drainpipe.
The connection port of the flexible hose and PVC drainpipe must be fixed with PVC adhesives. Check out that the connected part doesn't leak. Drain pipe type : VP25(AVXC4/ND4H)
2
Connect the flexible hose to the drain hose port. Make sure that a rubber ring is installed on the drain hose port. Drain hose port location differs depending on the unit types.
3
Install the drain pipe as shortly as possible. Give a slightly slant to the drainpipe for proper drainage of condensate water. There must be no gap on the connected part so that the drainpipe is not separated from the flexible hose.
Insulation cover band Insulation drainpipe
Indoor Unit
Drain hose port
Insulation cover drain
Band(Not supplied)
4
Insulate the drainpipe, and then fix it as indicated. [. . . ] When MAIN address is set as "12".
For Example
Setting RMC Address
You must set the SW03, SW04 and K2 switch when using the centralized controller. For Example When RMC address is set as "12".
SW03
SW04
E-21
AVXC4_IM_E_31758_1. 13. 10. indd 21
2010-1-13 17:00:14
Additional Functions
No.
K1 K2
Function
External room sensor Centralized controller Compensation RPM 1way/Slim 1way/2way/mini 4way 4way -
ON
Not use Not use Not use -
OFF
Use Use Use -
SW05
K1 K2 K3 K4
K3 K4
K1 OFF
Heating mode : Setting temperature compensation value = 0°F(0°C) Thermo OFF Fan OFF
No.
K5 Heating Current Temperature Compensation
Function
1way/Slim 1way/2way 4way/mini 4way Filter Time -
ON
3. 6°F(+2°C) 9°F(+5°C) 1000 hours -
OFF
9°F(+5°C) 3. 6°F(+2°C) 2000 hours -
SW06
K5 K6 K7 K8
K6 K7 K8
No.
K9
Function
Indoor Expansion Valve For Heating Stop Wired Remocon Group Master External control External Control Output
ON
Fix 80 step Not Use Not Use Thermal ON
OFF
0 or 80 step Use Use Operation ON
SW07
K9K10K11K12
K10 K11 K12
E-22
AVXC4_IM_E_31758_1. 13. 10. indd 22
2010-1-13 17:00:15
Final Checks and User Tips
ENGLISH
To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly.
1
Check the followings. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LM-V535A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LM-V535A will begin.