Detailed instructions for use are in the User's Guide.
[. . . ] Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In addition a gap between the front cabinet and the rear plate will become wider, spoiling the appearance.
CAUTION
· Be sure to refer the wiring system diagram labeled inside the front panel. · Check local electrical codes and also any specific wiring instructions or limitation.
Terminal block Connecting cable Cord Terminal clamp cover Screw
12
Push
Earth line
Push 1
Push 2
3
abo
ut 1
5cm
Screw Screw Connecting cable
4 Push
Fig. Piping and Drain Hose Installation
<In case of rightward piping> · After scribing slits of the front panel and the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like.
Slit (front panel)
To connect pipe after installation of unit (figure)
(To the forefront of flare)
196mm 96mm
Side of liquid flow Side of gas flow Outward form of indoor unit
43mm
R 30mm (Use polisin or the like for bending pipe. )
80
°
Use the handle of screwdriver, etc.
Slit (rear panel)
Fig. 8-4-14 NOTE : If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to auxiliary pipes and wrap the facing tape around them.
Fig. 8-4-12 <In case of downward piping> · After scribing the slit of the front panel and slit in the lower part of the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like.
CAUTION
· Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.
Indoor unit Auxiliary pipes Connecting cable
Slit (front panel)
Slit (rear panel)
Fig. 8-4-13 <Left-hand connection with piping> Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use spring bender so as not to crush the pipe. Bend the connection pipe within a radius of 30 mm.
Installation plate
· Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. · A place which does not block a passage. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. · An allowable length of the connecting pipe is up to 15 m. · An allowable head level is up to 6 m. · A place where the drain water does not raise any problem.
CAUTION
Installation in the following places may result in trouble. · A place where high-frequency waves are likely to be generated as from radio equipment, welders, and medical equipment.
CAUTION
(1) Install the outdoor unit without anything blodking the air discharging. (2) When the outdoor unit is installed in a place exposed always to a strong wind like a coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. (3) Specially in windy area, install the unit to prevent the admission of wind.
Strong wind
Fig. Refrigerant Piping Connection
<Flaring> (1) Cut the pipe with a pipe cutter.
8-5-2. Vacuum Pumping
AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump.
90°
Obliquity
Roughness
Warp
Do not use the refrigerant in the outdoor unit. For details, see the manual of vacuum pump.
Fig. [. . . ] (4 x 14 ) 3) Remove the electrical part base. 3) Disconnect the terminal blocks connected with the connecting cable, and the power cord from base Eparts by removing the screws. 4) Remove the thermal fuse (77°C) from base E-parts. Remarks Replace the thermal fuse, terminal block, power cord, microcomputer ass'y and the power supply PC board ass'y.
Thermal fuse replacement
50
10-3. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LMNC186D3M0
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.