Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LMNH366TDA0. We hope that this LG LMNH366TDA0 user guide will be useful to you.
Lastmanuals help download the user guide LG LMNH366TDA0.
Detailed instructions for use are in the User's Guide.
[. . . ] Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air This manual explains how to install an indoor unit with a split system with two LG units. The use of other types of
units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units. The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the "Operating limits" table, included in the manual, shall immediately invalidate the warranty. [. . . ] The terminal is connected too firmly , the terminal may be damaged.
E-16
09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 16
2009-11-24 9:19:55
INSTALLING THE OUTDOOR UNIT
MH070FXA4B / MH080FXA4B A-unit
1(L) 2(N) F1 F2
B-unit
1(L) 2(N) F1 F2
Indoor unit
C-unit
1(L) 2(N) F1 F2
D-unit
1(L) 2(N) F1 F2
1
2
F1 F2
1
2
Assembly cable
F1 F2
1
2
F1 F2
1
2
F1 F2
B
Earth terminal
2
Earth terminal
C
F1 F2
B 1 2
C
F1 F2
B 1 2
Earth terminal
C
F1 F2
B 1 2
Earth terminal
C
F1 F2
1
Earth terminal
Earth terminal
Earth terminal
Earth terminal
Outdoor unit
1(L) 2(N) 1(L) 2(N) 1(L) 2(N) 1(L) 2(N)
L
N
Main Power supply cable
F1 F2 F1 F2
F1 F2 F1 F2
A
B
C
D
A
1 A 2
B
C
D
Power cable to indoor units
Earth terminal
Communication cable to indoor units
Cable Type: A Cable Type: B Cable Type: C
Screw M4 M5
The specification for cables :
Model MH040FX*A2B MH040FX*A2C MH050FX*A2B MH050FX*A2C MH18VF1X MH19VF1X MH060FX*A3B MH070FX*A4B MH080FX*A4B Main Power Supply Cable Indoor Power Supply Cable Type Specication Type Specication
Torque(kgf. cm) Unfasten Torque Tighten Torque 17~30 25~40 20~35 30~50
FUSE MCCB Type GL
Communication Cable Specication Type
3G, 2. 5mm2 or more, H07RN-F
3G, 1. 0mm2 or more, H07RN-F
2G, 0. 75mm2 or more, H07RN-F
20A
Frame : 30A Trip : 20A Frame : 30A Trip : 25A Frame : 30A Trip : 30A
20A
20A 30A
25A 30A
Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of 3mm. The terminal is connected too firmly , the terminal may be damaged.
E-17
09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 17
2009-11-24 9:19:56
ENGLISH
INSTALLING THE OUTDOOR UNIT
Connecting the Cables to the Outdoor Unit (Continued)
Preparation of cables for outdoor unit terminal block
1 2 E
Main power supply cable: L(mm) Cable of indoor unit Main Power
L(mm)
1
2
E
20
20
90
Power cable to indoor units: L(mm) Cable of indoor unit A B C D
1 2 E
Remark
60 60 70 90
60 60 70 90
80 80 110 90 For 060/070/080 only For 070/080 only
Communication cable to indoor units : L(mm) Cable of indoor unit A The designs and shape are subject to change according to the model. B 15 C D 15 For 060/070/080 only For 070/080 only
1 2
Remark
E-18
09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 18
2009-11-24 9:19:57
INSTALLING THE OUTDOOR UNIT
Transmitter Installation (Optional)
ENGLISH
MH040FXA2B/MH040FXA2C/MH18VF1X/MH19VF1X Accessories (Transmitter: MIM-B13A)
Transmitter MAIN Transmitter SUB 485 Communication DC Power Cable Cable (12V)
DC Power Cable (5V)
Communication Cable
Cable Tie
Case
1 2
Turn the power off and take off the cover of the outdoor units. Fix the case with bolts to the side of the control box referring to the figure on the right side. In case of FJM outdoor unit, there is not enough space to fix all parts of transmitter. So you may use transmitter main PCB. Attach the transmitter main PCB to the case, then connect F1/F2 lines, R1/R2 lines which are upper controller communication cables and DC 12V power cables to the interface module referring to the figure on page 21. (Upper controller power should be off. ) You must check the position of dip switch on the transmitter main PCB and the main PCB of all of the indoor units. Assemble a cover of the outdoor unit and turn the power on. If you install a transmitter to the outdoor unit, every indoor unit which is connected to the outdoor unit can be controlled simultaneously. Each outdoor unit connected to the same centralized controller has its own transmitter.
Bolts spec. (not supplied with product)
OUTDOOR UNIT INSTALLED ON THE WALL BY RACK - Ensure the wall will be able to suspend the weight of rack and outdoor unit; - Install the rack close to the colum as much as possible; - Install proper grommet in order to reduce noise and residual vibration transferred by outoor unit towards wall.
Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)
E-22
09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 22
2009-11-24 9:20:16
COMPLETING THE INSTALLATION
Connecting Up and Purging the Circuit
ENGLISH
Indoor A-unit Indoor B-unit
WARNING
When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. The outdoor unit is loaded with sufficient R410A refrigerant. Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. MH040FXA2B/MH040FXA2C / MH050FXA2B/MH050FXA2C / MH18VF1X/MH19VF1X
1 Check the piping connections. 2 Connect the charging hose of low pressure side of manifold gauge to the
packed valve having a service port (MH040FXA2B/MH040FXA2C:3/8" service valve 2EA; MH050FXA2B/MH050FXA2C:3/8" service valve 1EA+1/2" service valve 1EA) as shown at the figure.
WARNING
Make the electrical connection and leave the system into "stand by mode". [. . . ] - Inlet air temp: From 11°K to 14°K (indicative delta T) In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space.
E-29
09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 29
2009-11-24 9:20:46
ENGLISH
COMPLETING THE INSTALLATION
Switch Setting and Testing Operation (Cont. )
It could take maximum 60 minutes to operate for the protection of the compressor if the outdoor temperature is below -5°C.
Ampere Limit Setting & Changing Procedure
WARNING Do not adjust the "Ampere Limit Switch", if it's not necessary: before modifying it, evaluate the total number of electric and electronics loads consumption and use "Ampere limits switch" just as emergency solution or in case the system is anyway oversized compared to real thermal load needed. "Ampere Limit Switch" is initially set to the default value (table below). The designs and shape are subject to change according to the model. "Ampere Limit Switch" is on the PCB of outdoor unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LMNH366TDA0
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LMNH366TDA0 will begin.