Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LMV1645SBQ. We hope that this LG LMV1645SBQ user guide will be useful to you.
Lastmanuals help download the user guide LG LMV1645SBQ.
Detailed instructions for use are in the User's Guide.
[. . . ] It is heavy and could cause personal injury if not handled properly.
· Avoid Electrical Shock!
Before you drill into the wall, note where electrical outlets are and where electrical wires might be concealed behind the wall. YOU COULD GET AN ELECTRIC SHOCK if you contact electrical wires with your drill bit. Locate and disconnect the power to any electrical circuits that could be affected by installing this oven. IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.
· ELECTRICAL RATING OF THIS OVEN : 120V AC 60Hz.
You need a DEDICATED 120V, 60Hz, AC only, 15 or 20A, fused electrical supply (located in the cabinet above the microwave as close as possible to the microwave) serving only the microwave.
2
Your Safety First
· THIS APPLIANCE MUST BE GROUNDED!
If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. [. . . ] Use duct tape to seal all joints in the duct system. Use caulking to seal the exterior wall or roof opening around the cap.
Room Venting
Roof Cap Cabinet
6"min diameter Round Duct Elbow 3 1/4" to Round Duct Transition
Wall Cap
Oven
3 1/4" to Round Ductwork Transition
Figure 8
Figure 9
8
STEP 2: Prepare The Venting System
Standard Fittings
NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper's sticking.
Duct Length
The total length of the duct system, including straight duct, elbows, transitions, and wall or roof caps must not exceed 140 feet. For best performance, do not use more than three 90 degree elbows, and keep the length as short as possible. Below are the standard fittings and their equivalent length in feet.
1
2
3
3 1/4" x 10" to 6" = 5 ft. 4 5
3 1/4" x 10" roof cap = 24 ft 6
3 1/4" x 10" 90° elbow = 25 ft 7
90°elbow = 10 ft
3 1/4" x 10" wall cap = 40 ft
45°elbow = 5 ft
3 1/4" x 10" flat elbow = 10 ft
Figure 10
To calculate the equivalent length of each duct piece used, see the examples below. Examples
For 3 1/4" x 10" SYSTEMS
6ft. wall cap
For 6" ROUND SYSTEMS
6ft. wall cap
2ft.
transition
2ft.
1 3 1/4" x 10" 90° elbow 1 Wall Cap 8 feet straight duct TOTAL LENGTH
= = = =
25 ft. 73 ft.
1 transition 2 90° elbows 1 Wall Cap 8 feet straight TOTAL LENGTH
= = = = =
5 ft. 73 ft.
9
STEP 3: Prepare The Venting Blower
Your microwave oven is shipped with the blower assembled for room-vented. You need to adjust the blower if you want wall-vented or roof-vented installation.
WARNING
ELECTRICAL SHOCK HAZARD!Measure the bottom of the upper cabinet frame. Trim the edges A, B, and C on the upper cabinet template so that the template will fit on the bottom of the upper cabinet. If upper cabinet has a recessed frame, trim the template so it fits inside the recessed area. Align the centerline of the upper cabinet template with the centerline of the mounting plate, then securely tape or tack the upper cabinet template in place. See Figure 24.
Mounting Plate
(1-piece Mounting Plate)
Upper Cabinet Template
Mounting Plate
(3-piece Mounting Plate)
Figure 24
13
STEP 4: Prepare The Wall & Upper Cabinet
WARNING
To avoid risk of personal injury, electrical shock or death: Note where electrical outlets and electrical wires are before you drill into the wall. Locate and disconnect power to any electrical circuits that could be affected by installing this oven.
WARNING
To avoid risk of personal injury, electrical shock or death, cover the edge of the power supply cord hole with the power supply cord bushing.
Drill The Holes In The Wall And Upper Cabinet.
1. If there is a stud, drill a 3/16" hole for lag screws. If there is no stud, drill a 3/4" hole for toggle bolts. Make sure to use at least 2 lag screws in a stud, and 4 toggle screws in the drywall or the plaster. Drill a 3/8" hole at points J and K on the upper cabinet template. NOTE: If the bottom of the upper cabinet is recessed 3/4" or more, you will need 2"x 2" filler blocks (not included) to provide additional support for the bolts. [. . . ] Remove the mounting plate and draw lines extending through the points. This will give the location and size of the box cutout for the rear wall duct. (Figure 29) 3-piece mounting plate: Use the wall template to determine the location and size of the box cutout for the rear wall duct. Attach the exhaust adaptor to the rear mounting plate (back plate) wall side. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LMV1645SBQ
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LMV1645SBQ will begin.