Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LP-C303R20. We hope that this LG LP-C303R20 user guide will be useful to you.
Lastmanuals help download the user guide LG LP-C303R20.
Detailed instructions for use are in the User's Guide.
[. . . ] website http://www. lgservice. com e-mail http://lgservice. com/techsup. html
LG
ENGLISH
LG Floor Standing Type Air Conditioner
OWNER'S MANUAL
FRANÇAIS ESPAÑOL
IMPORTANT
· Please read this owner's manual carefully and thoroughly before installing and operating your air conditioner. · Please retain this owner's manual for future reference after reading it thoroughly.
Floor Standing- Type Air Conditioner Owner's Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions. . . . . . . . . . . . . . . . . 3
Write the model and serial numbers here: Model # Serial #
Operating Instructions. . . . . . . . . . . 9
You can find them on a label on the side of each unit. Dealer's Name Date Purchased
Maintenance and Service . . . . 25 Celsius(°C) Fahrenheit (°F) Convert Table . . . . . . . . . . . . . . . . . . . . . . . 29
I Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. [. . . ] · Be sure that the (+) and (-) directions are correct. · Be sure that both batteries are new. · Slide the cover into back position. · Do not use rechargeable batteries such batteries as different from standard dry cells in shape, dimensions, and performance. · Change the batteries with a new one if the remote control does not work properly after using for an extended length of time.
Owner's Manual 13
Operating Instructions
Cooling Operation Mode
1
Press the on/off button. (or touch anyplace of touch panel and touch the on/off key)
2
Select Cooling Operation. Press the mode Operation Button on the remote controller (or Touch the mode Operation key on the touch panel)
ON OFF
SET
CANCEL
3
Set the temperature lower than the room temperature. The temperature can be set within a range of 60°F~86°F by 1°F.
To raise the temperature To lower the temperature
4
When you finish the temperature setting.
After 4 seconds
5
Set the Fan Speed.
Low
High
Super High
Each time the Fan Speed Button is pressed (or fan speed key is touched), the Fan Speed mode is shifted in the arrow direction.
14 Floor Standing-Type Air Conditioner
Operating Instructions
Soft Dry Operation ENGLISH
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
2
Select Soft Dry Operation Press the mode Operation Button on the remote controller (or Touch the mode Operation key on the touch panel)
ON OFF
SET
CANCEL
3
Set the temperature lower than the room temperature. The temperature can be set within a range of 60°F~86°F by 1°F.
To raise the temperature To lower the temperature
4
When you finish the temperature setting.
After 4 seconds
5
During Soft Dry Operation. The indoor fan speed is automatically set to low and can be set fan speed.
Low
High
Super High
Owner's Manual 15
Operating Instructions
TURBO-Z Operation
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
2
Press the TURBO-Z button to operate the speed cooling mode and the unit will operate in super high fan speed in cooling mode.
3
To cancel the TURBO-Z mode, press the TURBO-Z button again or the Auto Swing Direction Control Button (Up & Down, Left & Right) or Operation Mode Button and the unit will operate in High. Fan speed on cooling mode.
ON OFF ON OFF
or
SET
CANCEL
or
or
SET
CANCEL
NOTICE
During the TURBO-Z function at any moment, the A/C starts to blow the cool air at extremely high speed setting the room temp. It is especially used to cool the room in shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the TURBO-Z function is not available.
16 Floor Standing-Type Air Conditioner
Operating Instructions
Auto Operation Mode ENGLISH
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
controller 2 Press the Mode Operation Button on the remotepanel) (or Touch the Mode Operation key on the touch
ON OFF
Select Auto operation mode
SET
CANCEL
3
Set the temperature upper or lower than the standard temperature. The temperature can be set within a range of by 1 level.
Cold Cool Proper Warm
Hot
(This indication will be shifted to the initial Auto Mode Display state after 4 seconds. )
To raise the temperature To lower the temperature
Owner's Manual 17
Operating Instructions
Energy Saving Mode
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
2 Press the Energy Operation Button on the remote controller (or Touch the Energy Saving Operation key on the touch panel)
ON OFF SET CANCEL
Select Energy Saving Operation
3 and the unit will operate on Cooling/Auto/Soft Dry mode.
ON OFF SET CANCEL
To cancel the Energy Saving mode. Press(Touch) the Energy Saving Button(Key) Again
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
18 Floor Standing-Type Air Conditioner
Operating Instructions
Airflow Direction Procedure ENGLISH
1
Press the on/off button (or touch the anyplace of touch panel and touch the on/off key)
2
Press the Auto Swing Button and then louvers will swing Up and down. Press the Airflow Direction Control Button again to set the Horizontal louver at the desired airflow direction.
(Operation will start when the button is pressed, and stop when the button is pressed again.
The horizontal louver swing up and down.
Side Airflow Direction Control
Adjust the vertical airflow direction manually by moving the Vertical Vanes with hand.
1
Press the on/off button (or touch the anyplace of touch panel and touch the on/off key)
2
Press the Auto Swing Button and then louvers will swing left and right. Press the Airflow Direction ON OFF Control Button again to set the Vertical louver at the SET CANCEL desired airflow direction.
(Operation will start when the button is pressed, and stop when the button is pressed again.
The vertical louver swing left and right.
Owner's Manual 19
Operating Instructions
Plasma Air Purifying Operation Procedure
1
Air Purifying Operation only
1 Press(Touch) the Plasma Air Purifying Operation.
ON OFF SET CANCEL
(Operation will start when the button is pressed, and stop when the button is pressed again. )
2 Select Fan speed. The display shows
Low
High
· You can operate the Plasma Air Purifying under the unit operation of cooling, soft dry or Auto operation mode.
2 Air Purifying Operation with Cooling or any other Operation.
1. Press(Touch) the Plasma Air Purifying Operation button(key) 4. Set the fan speed.
20 Floor Standing-Type Air Conditioner
Operating Instructions
OFF Timer Setting Procedure(OFF TIMER Setting, or CANCEL) ENGLISH
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
2
Press the Timer Button.
ON
OFF
SET
CANCEL
· If you press the button, the selected off timer is displayed as follows;
· If you select `
', the Off Timer function will be cancelled.
3
When you finish the Off Timer setting, the Timer indicator lights off.
After 4 seconds After 4 seconds
4
During off-timer operation if you press the Timer Button, the rest time will be displayed.
Owner's Manual 21
Operating Instructions
°C °F switching button
1
Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key)
2
Touch the fan speed and on/off keys simultaneously for 3 seconds. The unit will respond with beep.
After 4 seconds
3
°C °F switching button
ON
OFF
SET
CANCEL
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
22 Floor Standing-Type Air Conditioner
Operating Instructions
Child Lock Operation Procedure ENGLISH
Touch the fan speed and high temperature setting keys simultaneously for 3 Sconds. The unit will respond with beep.
1
After 3 second, it will shift After 3 second, it will shift
2 Whenever you Touch any key on Touch panel, it will immediately display
" ", which means Touch panel is Locked. All the key on the indoor unit Touch panel will not work. [. . . ] This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency. This is caused by the compressor cycle starting and stopping. · You see water dripping from the rear of the unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LP-C303R20
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LP-C303R20 will begin.