Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LRNU09GSF10. We hope that this LG LRNU09GSF10 user guide will be useful to you.
Lastmanuals help download the user guide LG LRNU09GSF10.
Detailed instructions for use are in the User's Guide.
[. . . ] WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROL BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 3) Connect the flange and each type of duct. 9-4-9)
Thermal insulator (50mm (w), 6mm (t)) Seal Aluminum tape : (50mm-width) ( Thermal insulator(t) ) 25mm (w), 6mm 25mm End B Indoor unit Square duct board (25mm)
A
Fig. 9-4-9
CAUTION
Incomplete thermal insulation of the supply air flange and sealing may occur dewing resulted in falling of water drop.
29
[Square duct]
Thermal insulator with sticking material (50mm-width, 6mm (t)) Aluminum tape (Seal : 50mm-width)
Thermal insulator at indoor unit side (Stuck already at shipment from the factory)
Fit to the arrow arrow direction by pushing.
Screws (6 pieces) Indoor unit side
Flange (procured locally) Attach by pushing to the arrow direction. (Outside corner direction) Square duct board (25mm-thickness, 64kg/m³ or equivalent) Seal/thermal insulator with sticking material (25mm-width, 6mm (t))
Fig. 9-4-10
[Round duct]
Thermal insulator with sticking material (50mm-width, 6mm-thickness) Aluminum tape (Seal : 50mm-width) Thermal insulator at indoor unit side (Stuck already at shipment from the factory)
arrow Fit to the arrow direction by pushing.
Screws (6 pieces)
Round duct Thermal insulator (25mm-thickness, 24kg/m³ or equivalent) Flange Seal/thermal insulator with sticking material (25mm-width, 6mm (t))
Fit the seal/thermal insulator (25mm-width, 6mm-thickness) by pushing to the arrow direction so that no clearance can be found between the flange and the round duct.
Fig. Return air side When you do not connect the duct to the return air side (using steel and others), apply a protective measures so that your hands or fingers do not directly touch with the motor or other electric parts. Return air from rear side 1) Follow the procedure same as that for the supply air side. Flange mounting Square duct making Connecting work 2. Return air from lower side 1) Remove the cover for return air at the lower side of the indoor unit, and attach the cover to the opening port at the rear side of the indoor unit.
Cover for return air
Fig. 9-4-12 2) Mount the flange to the place from where the cover for return air was removed. 4) Arrange the flange and the square duct.
30
9-4-5. Connection of the Drain Hose
· Insert the drain hose completely into the connecting port of the drain pan. · Apply thermal insulation surely to the drain hose with elbow thermal insulation cover. 9-5-3
20 Extended ventilating pipe
Insert the hose completely up to the end.
25 or more
Downward grading 1/100 or more
Fig. 9-5-4
Drain hose Elbow thermal insulation cover Be sure to apply thermal insulation.
Drain kit (Option) For drain-up kit installation. Refer the installation manual supplied with the drain-up kit.
Fig. If the outdoor units are to be mounted on a wall, make sure that the platform supporting is sufficiently strong. The platform should be designed and manufactured to maintain its strength over a long period of time, and sufficient consideration should be given to ensuring that the outdoor unit will not fall. Use copper pipe with 0. 8 mm or more thickness. Flare nut and flare works are also different from those of the conventional refrigerant. Take out the flare nut attached to the main unit of the air conditioner, and use it.
· Flaring size : A (Unit : mm)
Outer diam. of copper pipe 6. 35 9. 52 12. 7 A R410A 9. 1 13. 2 16. 6
+0 - 0. 4
R22 9. 0 13. 0 16. 2
* In the case of flaring for R410A with the conventional flare tool, pull out it approx. [. . . ] 5) Remove 4 fixing screws (FT screw) of the motor cover. WARNING · When removing the four fixing screws of the motor cover, the fan and fan motor come down simultaneously. Be sure to deposit the motor cover while holding it by hands. Otherwise, it may be resulted in falling of motor with heavy weight. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LRNU09GSF10
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LRNU09GSF10 will begin.