If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LRNV282BGA0.ANWALAT. We hope that this LG LRNV282BGA0.ANWALAT user guide will be useful to you.
Lastmanuals help download the user guide LG LRNV282BGA0.ANWALAT.
Manual abstract: user guide LG LRNV282BGA0.ANWALAT
Detailed instructions for use are in the User's Guide.
[. . . ] (This restriction should be strictly kept for correct control of the refrigerant. ) Up to two fresh air intake units can be connected on one line of the multi system. The allowable total capacity of the two fresh air intake units shall be 30% or less against the total capacity of the indoor units (including the fresh air intake units). Connection which stretches over two floors is unavailable
Height difference: 0. 5m or more
3
1. System summary
Fresh Air Intake Indoor Unit Type 3. [. . . ] * An option humidifier is not available with Fresh Air Intake Indoor unit. * Height difference between Fresh Air Intake Indoor units must be within 0. 5m. Height difference between Fresh Air Intake Indoor unit and standard FCU must be within 30m. Cooling : Outdoor air temperature 33°C DB/28°C WB setting temperature 18°C Heating : Outdoor air temperature 0°C DB/-2. 9°C WB setting temperature 18°C Piping : Length 7. 5m / Height 0m Note 2: The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values meausured in the actual operating environment become large than the indicated values due to the effects of external sound. Note 3: * When supply air temperature is "setting temperature + 3°C" or less, Fresh Air Intake unit operates as FAN mode. * When supply air temperature is 19°C or less, Fresh Air Intake Indoor unit operates as FAN mode. Note 4: * When supply air temperature is "setting temperature - 3°C" or over, Fresh Air Intake unit operates as FAN mode. Specifications
Fresh Air Intake Indoor Unit Type
Model name Cooling/Heating capacity (Note 1) Electical Power supply characteristics Running current Power consumption Starting current Height Main unit Width Depth
60Hz
Outer dimension dimension Total weight Main unit Heat exchanger Soundproof / Heat-insulating material Fan unit Fan
Standard air flow Motor External static pressure (factory setting) External static pressure Air flow limit (m3/h) Lower limit/Upper limit Air filter Controller Connecting pipe
MMD-AP0481HFE LRNV282BGA0. ANWALAT MMD-AP0961HFE (kW) 14. 0/8. 9 22. 4/13. 9 28. 0/17. 4 1 phase 60Hz 220V (A) 1. 66 2. 75 3. 12 (kW) 0. 34 0. 55 0. 65 (A) 3. 40 6. 80 6. 80 (mm) 492 (mm) 892 1, 392 (mm) 1, 262 93 144 (kg) Finned tube Non-flammable insulation Centrifugal fan 3 1, 080 1, 680 2, 100 (m /h) 160 160 x 2 (W) 215 115-215-260 1, 188 210 150-210-235 1, 848 Option or field supply Wired remote controller 22. 2 12. 7 R1 46/45/44 66/65/64 5 - 43 -5 - 43 180 80-180-220 2, 310
Gas pipe Liquid pipe Drain pipe Sound pressure level (Note 2) (High/Med. /Low) Sound power level (High/Med. /Low) Operation range Cooling (Note 3) Heating (Note 4)
(mm) (mm) (dB(A)) (dB(A)) (°C) (°C)
15. 9 9. 5
45/43/41 65/63/61
* The setting temperature is 16 - 27°C(standard FCU. . . 18 - 29°C). * An option humidifier is not available with Fresh Air Intake Indoor unit. * Height difference between Fresh Air Intake Indoor units must be within 0. 5m. Please refer to the wiring diagram for details. Please note that the size is different because of MMD-AP0481HFE and LRNV282BGA0. ANWALAT/MMD-AP0961HFE in the electric part box. The heat insulator is pasted to externals of the main body of the product. (Bottom board thickness : 16mm, other thickness : 6mm) Be sure to set the duct at air filter with descending inclination because the suction duct of the this unit is exposed to outdoors and therefore rainwater, leaves and birds are easy to enter in if it is set horizontally. Attching wire netting and others to end of the suction duct is also recommended. Set the air inlet duct at descending inclination so that water can be drained even if rainwater enters in. The balloon entrance connection flange and the inhalation mouth connection flange are installed in the main body of the product. Please use it detaching it when you connect the duct. Please obtain Filter chamber directly in the main body of the product when you install Filter chamber and obtain installation Air intake port connecting flange for C side of A. Connect the ducts directly so that the ducts do not weight on the main unit. Moreover, please do not damage, and do not knock down air supply temperature sensor when you connect the air supply duct. [. . . ] Wiring diagrams
Line Filter
U1 U2 A B
1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI)
TR1
RED AB Outdoor Unit
Remote Controller Board
WHI Remote Controller
U1 U2
Fresh Air Intake Indoor Unit Type (8-10HP)
13
RED RED
F1
1
RED
Connector
T10A, 250V~ RED RED T10A, 250V~
COLOR IDENTIFICATION RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE BRW : BROWN G&Y : GREEN&YELLOW
8
6
RED RED
F2
3
WHI
6
43F2
ORN
WHI
5
43F1
43F1
ORN
4 5
4
Indoor Unit Earth Screw
WHI
3
R(L) YEL
S(N)
RC2
RC1
WHI RED GRY 4P 1234 1 2 3 4 (BLU) WHI RED GRY FAN2
WHI RED GRY
A
F1 BLU
F2 ORN
F3 BLK
F4
Symbol Closed-end Connector
Parts Name
1 2 3 4 4P 1 2 3 4 (WHI)
WHI RED GRY FAN1
A
F1 BLU
F2 ORN
F3 BLK
F4
FM1 2
Fan Moter
Power Supply 220-240V~50Hz 220V~60Hz
RC1 2
WHI RED GRY 4P 1234 1 2 3 4 (WHI) WHI RED GRY BLU 1 2 ORN 3 BLK
WHI RED GRY
TR1
Running Capacitor Transformer
1 2 3 4 4P 1 2 3 4 (WHI)
WHI RED GRY
1 BLU ORN
2 BLK
3
TA
Intake air temp. sensor
1.
FM2
G&Y G&Y
FM1
TC1, TC2, TCJ
Temp sensor
RY005~007
Fan Motor Control Relay
RY002
Drain Control Relay
Terminal block No. F1(Low static pressure tap) F2(Intermediate static Pressure tap) F3(High static pressure tap) F4
Fan moter wiring Blue(50/60Hz)
Note
PMV
Pulse Motor Valve
F1 2
Fuse for Fan Motor
43F1 2
Fan Motor Control Relay
Orange(50/60Hz) At shipment from factory Black(50/60Hz)
DP
Drain Pump Motor
FS
Float Switch
Sold Separately
indicates the terminal block. Letter at inside indicates the terminal number. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LRNV282BGA0.ANWALAT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.