User manual LG LRSPC2031NI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LRSPC2031NI. We hope that this LG LRSPC2031NI user guide will be useful to you.

Lastmanuals help download the user guide LG LRSPC2031NI.


Mode d'emploi LG LRSPC2031NI
Download
Manual abstract: user guide LG LRSPC2031NI

Detailed instructions for use are in the User's Guide.

[. . . ] E-8 · TIPS ABOUT INDICATOR PANEL . . . . . . . . . . . E-9 · PROGRESSIVE AIR FLOW . . . . . . . . . . . . . . . . . . . . . E-9 · ADJUSTING THE AIR FLOW DIRECTION . . . . . E-10 · 10°C OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · When you replace the batteries, always change both batteries, and make sure they are the same type. · If the remote control does not operate properly after replacing the batteries, take out the batteries and reinstall them again after 30 seconds. · If you will not be using the unit for a long time, remove the batteries from the remote control. HOW TO USE THE REMOTE CONTROL Point the remote control towards the unit's signal receiver window and press the desired button. The unit generates a beep when it receives the signal. · Make sure there is no curtain or other object between the remote control and the unit. · The remote control can send signals from up to 7 metres away. E-6 CAUTION · Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. · Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them. SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o'clock in the afternoon Clock Display 12-hour mode 24-hour mode PM 5:00 17:00 MODE 1h 1 To set to the 12-hour mode, press the CLOCK button once in the first step. The Plasmacluster ions reduce airborne mold fungus. AIR CLEAN OPERATION Plasmacluster ions released into the air will reduce airborne mold fungus. ION BALANCE OPERATION Plasmacluster Ion generator Plasmacluster ions It is said that plenty of negative ions exist in places such as waterfalls or waterside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to bring the room air close to this condition. SELF CLEAN OPERATION Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the growth of mold fungus, and dry inside of the air conditioner unit. Utilize the operation at seasonal change over terms. Mold fungus already grown can not be eliminated by this operation. E-12 PLASMACLUSTER OPERATION You can choose AIR CLEAN OPERATION or ION BALANCE OPERATION 1 During operation, press the PLASMACLUSTER button to select the mode. AIR CLEAN REMOTE CONTROL DISPLAY PLASMACLUSTER lamp on the unit ION BALANCE CANCEL BLUE lamp light up GREEN lamp light up Lamp goes off 1 DISPLAY · In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. · In the ION BALANCE operation, the green PLASMACLUSTER lamp on the unit will light up. TO CANCEL Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off. NOTES: · The PLASMACLUSTER lamp on the unit will turn off. · Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner. · To turn off the PLASMACLUSTER lamp, press the DISPLAY button. · When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg, HEATING or COOLING). The mode symbol of the remote control will go off and the fan speed can not be set AUTO. SELF CLEAN OPERATION 1 Press the SELF CLEAN button when the unit is not operating. · The remote control displays " ". · The blue PLASMACLUSTER lamp on the unit will light up. · The unit will stop operation after forty minutes. · The remaining operation time will be indicated on the TEMPERATURE INDICATOR of the indoor unit in minute decrements. MODE 1h CLEAN FAN 1 TO CANCEL Press the SELF CLEAN button. [. . . ] 3 Close the left cover until it clicks. Hole 1 Shaft Shaft Receiver 2 2 5 Connect the poweroncord to the wall outlet or turn the circuit breaker. 3 Cover E-18 ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE INDOOR TEMP. upper limit COOLING lower limit HEATING D. B. = Wet-bulb 32°C 23°C 21°C 15°C 27°C D. B. · The built-in protective device may prevent the unit from operating when used out of this range. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LRSPC2031NI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LRSPC2031NI will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag