[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] ([00] is displayed. ) · If [MODE] button is pushed while pushing [CHK] button, the small [B] is displayed at the right of the setting temperature indication section. * To reset [A] setting, push the [MODE] button again while pushing the [CHK] button.
10-4-2. Check the unit is firmly hooked up on the installation plate. Check the connecting pipes tightened securely. Confirm that all connecting cables are secured and correct. To switch the TEST RUN (COOL) mode, push [RESET] button for 10 sec. (The beeper will make a short beep. )
2. Confirm the indoor unit can operate with the changed setting of the remote controller.
RESET
Fig. Operate the unit at cooling operation mode for 15 minutes or more. Measure the temperature of the intake and discharge air. Ensure the difference between the intake temperature and the discharge one is more than 8°C. (For details, see the owner's manual. )
180
To pipe hole center
100mm
Pipe hole
65
mm
The center of the pipe hole is above the arrow.
100
Remote controller
· A place where there are no obstacles such as curtains, that may block the signal from the indoor unit. · Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote controller should be determined as shown below.
Fig. After determining the pipe hole position on the mounting plate (100 mm ð ), drill the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
NOTE : · When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.
Mounting the installation plate
For installation of the indoor unit, use the paper pattern on the back.
Indoor unit
(Side view)
(Top view) Indoor unit
Reception range
Remote controller
Reception range
Remote controller
*: Axial distance
Fig. 10-4-8
71
How to connect the connecting cable
Wiring the connecting cable can be carried out without removing the front panel. Open the air inlet grille upward and pull it toward you. Remove the terminal cover and cord clamp. Insert the connecting cable (according to local cords) into pipe hole on the wall. Take out the connecting cable through the cable slot on the rear panel so that it is exploded by about 15 cm long in the front side. Insert the connecting cable fully into the terminal block and secure it by screw tightly. [. . . ] P Board (RAS-M13SKCV) . C.
134
RAS-M22SKCV
227
205 218 207
212
204 230 202 229 228
209
226
203 210 222 225 201 224 223
206 232 233
Electric Parts Assembly
Location No. 201 202 203 204 205 206 207 209 210 212 218 222
Part No. 43T21371 43T22312 43T70313 43T20016 43T49010 43T83003 43T82008 43T19333 43T49043 43T39021 43T79313 43T39020
Description Motor, Fan Bearing Ass'y, Mold Hose, Drain Fan Ass'y, Cross Flow Pipe, Shield Holder, Remote Controller Plate, Installation Holder, Sensor Holder, Pipe Base, Bearing Cap, Drain Band, Motor, Left
Location No. 223 224 225 226 227 228 228 229 230 232 233
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LS-H226VML2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.