User manual LG LS-L1960ACL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LS-L1960ACL. We hope that this LG LS-L1960ACL user guide will be useful to you.

Lastmanuals help download the user guide LG LS-L1960ACL.


Mode d'emploi LG LS-L1960ACL
Download
Manual abstract: user guide LG LS-L1960ACL

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Run the drain hose at a downward sloped angle. NOTE · Hole should be made at a slight downward slant on the outdoor side. OK 50 mm or more NO GOOD Do not form the drain hose into the waved shape. Do not rise the drain hose. 1 Hook here [1] Installation plate Do not put the drain hose end into water. Do not put the drain hose end in the drainage ditch. 2 Fig. Put water in the drain pan and make sure that the water is being drained outside. When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe. Shield pipe Hook Fig. 10-3-19 · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places. Drain hose Inside the room Extension drain hose Fig. 10-3-22 Push Push CAUTION Push (unhook) Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room. This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a high place above the drain guide. Wall Drain guide Fig. Accessory and Installation Parts Installation manual 1 Rubber cap (Water-proof) 5 CD-ROM (Installation manual) 1 F-GAS label 1 Drain nipple 1 10-4-2. Refrigerant Piping · Piping kit used for the conventional refrigerant cannot be used. Piping connections to the outdoor unit should be arranged in the sequence A, B, C, D, E starting from the bottom. (For each piping connection, the gas pipe is on the bottom and the liquid pipe is on the top. ) 2. When multiple indoor units are to be connected to the outdoor unit, make the ends of the pipes and wires from each indoor unit to ensure that they will be connected to the outdoor unit correctly. (Problems caused by indoor units being connected to the outdoor unit incorrectly are very common in multiple-unit installations. ) 3. The length and height difference of the connecting pipes between the indoor and outdoor units must be within the ranges indicated below. Additional refrigerant . . . . . . . . . . . . . . . . . . . . . . . 40 m Additional refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 to 80 m Additional 20 g of refrigerant . . . . . Per every 1 m · Minimum piping length : A or B or C or D or E = 3 m or more · Maximum indoor piping length : A or B or C or D or E = 25 m or less · Maximum piping height difference : A or B or C or D or E = 15 m or less · Maximum piping/height difference between 2 units = 15 m or less A 15 m or less 15 m or less 15 m or less 500 or more 150 or more 1000 or more Fig. 10-4-2 C Side view (Unit: mm) 500 or more 1000 or more Outdoor unit D E 150 or more 1000 or more B Fig. Connect 2 or more indoor units for heat pump. [. . . ] If the cover of the sensor lead wire is damaged, it is dangerous because an electric shock or fire may be caused. NOTE) After replacing of parts, check the sensors are mounted at the specified positions. If there are incorrect mounted positions, control of the product does not operate correctly and a trouble may be caused. Pass TG sensor through the Bundling band upper side of connecting pipe of Td sensor PMV unit (Black) and then bind Case thermo it with lead wire of PMV coil. Reactor lead NOTE) Using the bundling band being on the market, be sure to bind the position which was bound. ­ 139 ­ No. 19 Part name Sensor wiring process (Continued) Procedure Bind TS sensor, TE sensor and TO sensor with the bundling band. Pass TE sensor and TO sensor through upper part of the inverter fixing board and then bind them with the bundling band. Remarks Inverter fixing board NOTE) Using the bundling band being on the market, be sure to bind the position which was bound. Bundling band TS sensor TE sensor TO sensor Bundling band TE sensor TO sensor ­ 140 ­ 13. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LS-L1960ACL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LS-L1960ACL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag