Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LS-Q096ADG. We hope that this LG LS-Q096ADG user guide will be useful to you.
Lastmanuals help download the user guide LG LS-Q096ADG.
Detailed instructions for use are in the User's Guide.
[. . . ] HOW TO REPLACE THE MAIN PARTS
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 11-2 11-3 11-4 Indoor Unit (E - Parts Assy) Indoor Unit Outdoor Unit (RAS-18SA-ES, RAS-24SA-ES) Outdoor Unit (RAS-18S2AH-ES, RAS-24S2AH-ES)
-2-
FILE NO. SPECIFICATIONS
MODEL ITEM Capacity Power source Power consumption Power factor Running Current Indoor/Outdoor Starting current Moisture removal Noise Indoor (H/M+/M/L+/L) Outdoor (220-240V) Refrigerant Name of refrigerant Rated amount Refrigerant control Interconnection Gas side size pipe Connection type Liquid side size Connection type Maximum length (One way) Maximum height difference INDOOR UNIT Dimensions Height Width Depth Net weight Evaporator type Indoor fan type Airflow volume High fan Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Dimensions Height Width Depth Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Model Output Safety device Louver type Usable outdoor temperature range kW Phase V Hz W % A A lit/h dB dB kg mm mm m m 220V 5. 30 RAS-18SKP-ES RAS-18SA-ES Cooling 240V 5. 35
1 220 - 240 50
RAS-24SKP-ES RAS-24SA-ES Cooling 220V 6. 80 240V 6. 85
1640 98 0. 3/7. 30
1680 97 0. 3/6. 90
2410 98 0. 50/14. 70
2450 93 0. 50/12. 90
31 2. 0 44/42/39/37/35 56 1. 65 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 20*2 8 RAS-18SKP-ES 320 1050 228 13 Finned tube Cross flow fan 1000 880 750 15*
1
44 2. 7 45/43/41/39/37 57 R410A 1. 70 56 57
25*2 10 RAS-24SKP-ES
mm mm mm kg
m3/h 3 m /h m3/h W
1100 950 850
mm mm mm kg
m3/h W W
°C
30 Honeycomb woven filter with PP frame RAS-18SA-ES RAS-24SA-ES 715 780 290 45 50 Finned tube Propeller fan 2400 2550 2450 2600 42 PA270X3CS-4MU2 PA200X2CS-4KU1 2000 1500 Fuse , IOL Automatic louver 15 ~ 43
Note *1 Chargeless pipe *2 Maximum pipe
-3-
FILE NO. SVM-09036
MODEL ITEM kW Phase Power source V Hz Power consumption W Power factor % Running Indoor A Current Outdoor A Starting current A Moisture removal lit/h Noise Indoor (H/M+/M/L+/L) dB Outdoor (220-240V) dB Refrigerant Name of refrigerant Rated amount kg Refrigerant control Interconnection Gas side size mm pipe Connection type Liquid side size mm Connection type Maximum length m (One way) Maximum height m difference INDOOR UNIT Dimensions Height mm Width mm Depth mm Net weight kg Evaporator type Indoor fan type Airflow volume High fan m3/h 3 Medium fan m /h Low fan m3/h Fan motor output W Air filter OUTDOOR UNIT Dimensions Height mm Width mm Depth mm Net weight kg Condenser type Outdoor fan type Airflow volume m3/h Fan motor output W Compressor Model Output W Safety device Louver type Usable outdoor temperature range °C Capacity
LS-Q096ADG RAS-18S2AH-ES Cooling Heating 220V 240V 220V 240V 5. 10 5. 12 5. 45 5. 56
1
RAS-24SKHP-ES RAS-24S2AH-ES Cooling Heating 220V 240V 220V 240V 6. 30 6. 35 6. 80 6. 90
220 - 240 50
1540 98 6. 85
1580 96 0. 30 6. 55
1470 98 6. 55
1530 97 6. 30
2190 98 9. 90
2250 93 0. 30 9. 80
2050 98
2140 93 9. 30
31 2. 0 44/42/39/37/35 56-57 1. 53 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 20* 8 LS-Q096ADG 320 1050 228 13 Finned tube Cross flow fan 1000 880 750 1000 900 770 1100 950 850
2
9. 20 44 2. 5 45/43/41/39/37 57-58 1. 62
57-58 R410A
56-57
15*
1
25*2 10 RAS-24SKHP-ES
1100 950 850
30 Honeycomb woven filter with PP frame RAS-18S2AH-ES RAS-24S2AH-ES 715 715 780 780 290 290 47 53 Finned tube Propeller fan 2400 2550 2400 2550 2400 2550 2400 2550 42 PA200X2CS-4KU1 PA270X3CS-4MU2 1500 2000 Td sensor , Fuse , IOL Automatic louver 15 ~ 43 -10 ~ 24 15 ~ 43 -10 ~ 24
Note *1 Chargeless pipe *2 Maximum pipe
-4-
FILE NO. [. . . ] · A place where the drain water does not raise any problem.
FILE NO. Cut the pipe with a pipe cutter.
Obliquity Roughness Warp
90°
Fig. Insert a flare nut into the pipe, and flare the pipe. · Projection margin in flaring : A (Unit : mm)
A
Die
Pipe
Fig. of copper pipe 6. 35
12. 70
CAUTION
1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. Installation in the following places may result in trouble. · A saline-place such as the coast. · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment.
R410A tool used 0 to 0. 5
0 to 0. 5
Conventional tool used 1. 0 to 1. 5
1. 0 to 1. 5
Imperial (wing nut type, conventional tool) Outer dia. Incorrect connections may cause not only a gas leakage, but also damage to the refrigerant cycle.
Flare at indoor unit side
Flare at outdoor unit side
Fig. 8-5-4
Half union Flare nut
Externally threaded side
Internally threaded side
Use a wrench to secure.
Use a torque wrench to tighten.
Fig. 8-5-5
CAUTION
· KEEP IMPORTANT 5 POINTS FOR PIPING WORK (1) Take away dust and moisture (Inside of the connecting pipes. ) (2) Tight connection (between pipes and unit) (3) Evacuate the air in the connecting pipes using VACUUM PUMP. (4) Check gas leak (connected points) (5) Be save to fully open the packed valves before operation.
Compound pressure gauge
Pressure gauge Manifold valve Handle Hi (Keep full closed) Charge hose (For R410A only) Vacuum pump adapter for counter-flow prevention (For R410A only)
Vacuum pump
101 kPa (76 cmHg) Handle Lo
Charge hose (For R410A only) Connecting pipe
Packed valve at liquid side Packed valve at gas side
Service port (Valve core (Setting pin))
Fig. SVM-09036
TO CHARGE REFRIGERANT
Terminal block
LN
L N 1 2 3
12 3
10 10 10
Refrigerant
No need to charge extra refrigerant Need to charge extra refrigerant
10
24 class
15 m or less Over 15 m up to 25 m (20 g/m)
18 class
60
100 70
80
Terminal screw
15 m or less Over 15 m up to 20 m (20 g/m)
Earth line Cord clamp Screw Cord clamp Power supply cord Connecting cable
Earth line
Power supply cord
Connecting cable
<Packed valve handling precautions> · Open the valve stem all the way out; but do not try to open it beyond the stopper. · Securely tighten the valve stem cap with torque in the following table:
Fig. 8-5-8
Model
Power s ource
Maximum running current Plug s o c k e t & f u s e r a t i n g Power cord
24 Class
18 Class
50 Hz, 220 240 V Single phase
18A 20A 16A 20A
Gas side Gas side (12. 70 mm) Liquid side (6. 35 mm) Service port
Tightening torque 60 to 62 N·m (6. 0 to 6. 2 kgf·m) 16 to 18 N·m (1. 6 to 1. 8 kgf·m) 9 to 10 N·m (0. 9 to 1. 0 kgf·m)
A 4 mm Same as Gas side
2 4 mm (H07R N-F or 245 IE C 66) or 3. 5 mm2 (AWG -12)
CAUTION
· Wrong wiring connection may cause some electrical parts burn out. · Be sure to comply with local codes on running the wire from indoor unit to outdoor unit (size of wire and wiring method etc). · Every wire must be connected firmly. NOTE: Connecting cable · Wire type: More than 1. 5 mm2 (H07RN-F or 245 IEC66) or 1. 3 mm2 (AWG-16)
· Hexagonel wrench : A (Unit : mm) Hexagonal wrench is required.
A
Fig. Remove the valve cover from the outdoor unit. [. . . ] (7 screws 4 x 10L) (Pulling out upward) 2 screws 5) Remove the top cabinet. (2 screws 4 x 10L) 4 x 10L (Pull the front right portion toward you, and remove it pulling out upward)
Remarks
Top cabinet
Side cabinet
Packed valve cover
2 Cord clamps
4 screws 4 x 16L 7 screws 4 x 10L
Front cabinet
- 74 -
FILE NO. SVM-09036
No.
2
Part name
Running capacitor for compressor
Procedures
1) Perform the common procedure 1 2) Remove the capacitor band. (1 screw 4 x 10L) 3) Disconnect the lead wires from the capacitor terminal. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LS-Q096ADG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LS-Q096ADG will begin.