User manual LG LSNE0961CL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LSNE0961CL. We hope that this LG LSNE0961CL user guide will be useful to you.

Lastmanuals help download the user guide LG LSNE0961CL.


Mode d'emploi LG LSNE0961CL
Download
Manual abstract: user guide LG LSNE0961CL

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indoor Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Outdoor Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Operation Characteristic Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] DC18V YES Are two remote controllers set without master unit?Defect Replace YES Correct as a master unit/a sub unit (Remote controller address connector) Check remote controller P. C. Defect Replace [E09 error] Are two remote controllers set without master unit?NO YES Correct as a master unit/a sub unit (Remote controller address connector) Check remote controller P. C. Defect Replace ­ 55 ­ [E04 error] NO Does outdoor unit operate?YES NO Is setup of group address correct?YES NO Are 1, 2, 3 inter-unit cables normal?YES Are connections from connectors of inter-terminal blocks (1, 2, 3) of indoor/outdoor units normal?YES Does voltage between 2 and 3 of inter-terminal blocks (1, 2, 3) of indoor unit vary?* YES NO Check indoor P. C. Defect Replace NO Correct connection of connector. Check item code [14]. * As shown in the following figure, perform measurement within 20 seconds after power ON. YES NO Are characteristics of TA sensor resistance value normal?NO Correct connection of connector. ­ 58 ­ [P12 error] <Only for 4-way air discharge cassette type models> Turn off the power. Are not there connections errors or disconnection on connectors CN333 and CN334 of indoor unit P. C. NO Remove connectors CN333 and CN334 of indoor unit P. C. board (MCC-1402). YES Correct connection of connector. Does the fan rotate without trouble when handling the fan with hands?YES Are resistance values between phases at fan motor connector CN333 motor side of indoor P. C. *1 YES NO Replace indoor fan motor. NO Replace indoor fan motor. *1 · Are not coil windings between 1 (Red lead) and 3 (White lead), between 3 (White lead) and 5 (Black lead), between 5 (Black lead) and 1 (Red lead) opened or shorted? For resistance, see the following values. 70 to 100 NO Replace indoor fan motor. Is resistance value of fan motor connector CN333 at motor side of indoor P. C. *2 YES *2 Check resistance of fan motor position detection circuit. Is not coil winding between 1 (Yellow lead) and 4 (Pink lead) opened or shorted?5 to 20k NO Replace indoor fan motor. Is signal output of indoor fan motor position detection correct? [. . . ] 5) While holding the heat exchanger, remove fixing band and fixing screws (Ø4 × 10, 3 pcs. ) and then remove the heat exchanger. Remarks Piping cover 2. Attachment 1) Mount parts in order, heat exchanger fixing band piping cover drain pan bell mouth electric parts box as original. 3 screws NOTE) Arrange wires as original. 2) Attach the removed connectors and wires as original. 3) Connect the refrigerant pipe as original, and then perform vacuuming. Fixing band Fixing band for heat exchanger <Details of sensor lead wire drawing> TCJ sensor (Black) TC sensor (Red) 2 fixing screws for heat exchanger Wind pipe cover over the header, attach a sensor on it. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LSNE0961CL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LSNE0961CL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag