[. . . ] Holes in metal, through which insulated wires pass, shall have smooth well rounded surfaces or shall be provided with brushings.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. FCC WARNING : This equipment may generate or use radio frequency energy. [. . . ] (Set the Duration Time of Alarm Input function to "0" using the LKD1000 controller. ) ·
While operating Pattern function.
Auto mode: Change the observe position to a sensor that senses a touch or shock then return to the position that previously observed. (Set the Duration Time of Alarm Input function to "1 to 255". )
17
<Example : If this unit receives signal from "Alarm 8">
ALARM OUT connections
Connect an external device, for example, a buzzer or lamp, to this connector. Output specifications are lowactive, open-collector and a drive capacity of 30V DC 0. 5A maximum.
Before inputting the alarm signal Alarm signal input Released alarm signal
Alarm output numbers 1 to 4 are linked to alarm inputs 1 to 4 respectively. If alarm input 1 comes in, the camera sends output signals via the alarm output 1 connector on the camera. Note: Use a relay if the voltage or current of the connected device exceeds the ratings.
Data Port C Adapter
Function status While observe a specific position. While operating Auto Pan function.
Auto mode Change the observe position to the alarmed position then return to the position that previously observed. Stop preset touring and change the observe position to the alarmed position then restart the preset touring again. Stop auto panning and change the observe position to the alarmed position then restart the auto panning again. Stop operating pattern function and change the observe position to the alarmed position then restart the pattern function again.
Alarm devices (1-4)
While operating Pattern function. Note:
The Alarm In 1 is Preset 1, Alarm In 2 is Preset 2, Alarm In 3 is Preset 3, . . . , Alarm In 7 is Preset 7 and Alarm In 8 is Preset 8.
18
Connection of the data port and adapter for alarm output
· Data Port C No 1 2 3 4 5 6 7 8 Description ALARM OUT 1 COM 1 ALARM OUT 2 COM 2 ALARM OUT 3 COM 3 ALARM OUT 4 COM 4 Color Black Brown Red Orange Yellow Green Blue White
Data Port A or B
Adapter
LKD1000 controller
No 1 2 3 4 5 6 7 8
Description ALARM OUT 1 COM 1 ALARM OUT 2 COM 2 ALARM OUT 3 COM 3 ALARM OUT 4 COM 4 Alarm device 4 Alarm device 3 Alarm device 2 Alarm device 1
Color Brown Blue Yellow Green Red Black Orange White
Connection of the data port and adapter with LKD1000 controller
No 4 5 Description TRX D TRX D + Color Orange Yellow Connections
No 4 5
Description TRX D TRX D +
Color Green Red
TX-
TX+
Connecting LKD1000 controller
Connecting the LKD1000 controller to control the camera. (Refer to the manuals of the LKD1000 controller for more details. ).
TX-
TX+ TXTX+
19
System Connection
Note: When any peripheral is turned off and turned on again, the camera is also turned off and turned back on. PRESET /CAM1 PRESET /CAM1
Focus setting
Focus Mode setting
3. Press [Cam OSD] button to display the camera setup menu.
The camera adjusts the focus automatically by sensing the center of the picture. Select [FOCUS MODE] option on the [FOCUS] menu, then select the following mode. · · AUTO: Auto-focus is activated automatically. ONE PUSH: The focus is activated manually. If the camera is received auto-focus command, the camera is activated Auto-focus mode and the focus is set automatically and then the focus mode is automatically changed to manual mode. ZOOM TRIG: The focus is activated manually. If you change the zoom, the focus is activated Automatically and then the focus mode is automatically changed to manual mode. MANUAL: Focus is activated only when the FOCUS (NEAR or FAR) keys on the controller is pressed. Operation
At this point, you have access to the camera setup menu. ·
·
3
Focus Distance setting
Zoom Speed setting
Selects the minimum shooting distance for the focus. [. . . ] The Function On-Screen Display of this camera can be turned on or off. Select [OSD] option on the [SPECIAL] menu. Use [Near] or [Far] button to select a [ON] and press [Open] or [Close]. The OSD menu appears.
Freeze setting
1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LT1210CR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.