User manual LG LW-B0960CS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LW-B0960CS. We hope that this LG LW-B0960CS user guide will be useful to you.

Lastmanuals help download the user guide LG LW-B0960CS.


Mode d'emploi LG LW-B0960CS
Download
Manual abstract: user guide LG LW-B0960CS

Detailed instructions for use are in the User's Guide.

[. . . ] Use this appliance on a dedicated circuit. · There is risk of fire or electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. · Do not disassemble or repair the product. There is risk of fire or electric shock. Always ground the product. · There is risk of fire or electric shock. Install the panel and the cover of control box securely. · There is risk of fire or electric shock. Always install a dedicated circuit and breaker. · Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse. · There is risk of fire or electric shock. Do not modify or extend the power cable. · There is risk of fire or electric shock. Do not install, remove, or reinstall the unit by yourself (customer). · There is risk of fire, electric shock, explosion, or injury. Be cautious when unpacking and installing the product. · Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator. Owner's Manual 3 Safety Precautions For installation, always contact the dealer or an Authorized Service Center. · There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. · It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. · If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. n Operation Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. · Moisture may condense and wet or damage furniture. Take care to ensure that power cable could not be pulled out or damaged during operation. · There is risk of fire or electric shock. Do not place anything on the power cable. · There is risk of fire or electric shock. Do not plug or unplug the power supply plug during operation. · There is risk of fire or electric shock. Do not touch(operate) the product with wet hands. · There is risk of fire or electrical shock. Do not place a heater or other appliances near the power cable. · There is risk of fire and electric shock. Do not allow water to run into electric parts. · It may cause There is risk of fire, failure of the product, or electric shock. Do not store or use flammable gas or combustibles near the product. · There is risk of fire or failure of product. Do not use the product in a tightly closed space for a long time. · Oxygen deficiency could occur. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. · Do not use the telephone or turn switches on or off. There is risk of explosion or fire If strange sounds, or small or smoke comes from product. [. . . ] Operation Display of the Remote Control 3. Indoor Fan Speed Selection Button · To select the desired fan speed in two steps [Low, Mid] 4. Power ON/OFF Button · Operation will start when this button is pressed, and stop when the button is pressed again. Auto Airfloor Direction Control Button (No application) · The horizontal louvers swing up and down. Auto Airflow Direction Control Button · The vertical louvers swing left and right. 12 7 14 3 (Heat pump Model) 1 2 11 12 10 14 3 A/CL 9. Auto Mode Operation Button (Cooling Model Only) 10. Timer Set Button · Each time the button is pressed, the mode is changed in the following process. Time set (1, 2, 3, 4, 5, 6, 7 hours) If you select "0" the off Timer function will be cancelled. Electric heater On/OFF Button(Heat pump & Electric heater product only) 17. ENERGY Saving Operation Button(No application) 16 4 9 13 8 15 6 5 Wireless Remote Control Puts all functions at your fingertips Handling the remote control · Aim at the signal receptor on the floor standing type air conditioner when operating. · The remote control signal can be received at a distance of up to about 7meters. The unit will respond with beep, Child Lock Operation will removed. After pressing the buttons it will shift immediately After 3 seconds, it will shift Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. 18 Floor Standing-Type Air Conditioner Maintenance and Service Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. ENGLISH During the season Cleaning of the air filters. Recommended about once every two weeks Remove the Air Filter. Take hold of the tab and pull slightly forward to remove the filter. · To remove the dust adhering to the filters, either use a vacuum cleaner, or wash them in water and dry in the shade. · Re-insert the filter to the original position. Cleaning of the air cleaner. Recommended about once every three months Remove the Air Cleaner. Take hold of the tab and pull slightly forward to remove the air cleaner. · Dip the air cleaner into the water mixed with detergent, for 20~30 minutes, and dry in the shade. · Re-insert the air cleaner to the original position. Cleaning of the air conditioner · Dont wash with water. · Wipe with a soft dry cloth. Never use any of the followings. · Water hotter than 40°C. Could cause deformation and/or discoloration. [. . . ] · Condensation occurs when the airflow from the air conditioner cools the warm room air. · This is the Protection device of the air conditioner . · Wait about three minutes and operation will begin. · If the airflow begins before its temperature become warm, it will cause an undesired cooling effect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LW-B0960CS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LW-B0960CS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag