If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LW-G0960BCAAFRICA. We hope that this LG LW-G0960BCAAFRICA user guide will be useful to you.
Lastmanuals help download the user guide LG LW-G0960BCAAFRICA.
Detailed instructions for use are in the User's Guide.
[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used.
Anchor bolt Projection 15mm or less
Fig. 10-3-4
NOTE : · Perform wiring work being sure the wire length is long enough.
5 mm dia. Wiring Connection
How to connect the connecting cable
7 Mounting screw Ø4 × 25L
Clip anchor (local parts)
Fig. 10-3-5
CAUTION
Failure to securely install the unit may result in personal injury and/or property damage if the unit falls. · In case of block, brick, concrete or similar type walls, drill 5 mm dia. · Insert clip anchors for the mounting screws.
NOTE : · Install the installation plate using mounting screws between 4 to 6, being sure to secure all four corners.
Wiring the connecting cable can be carried out without removing the front panel. Open the air inlet grille upward and pull it toward you. Remove the terminal cover and cord clamp. Insert the connecting cable (or as according to local regulations/codes) into the pipe hole on the wall. Pull the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm out of the front. Insert the drain hose firmly until the connector contacts with the insulation, then secure it in place using the original screw.
9. 52 mm 12. 7 mm
To connect the pipe after installation of the unit (figure)
(To the front flare)
270 mm
Gas side
CAUTION
Securely insert the drain hose and drain cap; otherwise, water may leak.
230 mm
Liquid side
R30 or less (Ø6. 35), R40 or less (Ø9. 7) Use polishing (polyethylene core or the like for bending pipe).
43 mm
In case of right or left piping
· After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Outward form of indoor unit
Use a screwdriver handle, etc.
Fig. 10-3-15
NOTE : If the pipe is incorrectly bent, the indoor unit may be unstable on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.
62
CAUTION
· Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.
Indoor unit Auxiliary pipes Installation plate Connecting cable
10-3-7. Run the drain hose at a downward sloped angle.
NOTE : · Hole should be made at a slight downward slant on the outdoor side.
Do not rise the drain hose. Do not form the drain hose into the waved shape.
50 mm or more
Fig. 10-3-18 · Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit. · Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. · Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material. ) · When bending a pipe, be careful not to crush it.
Do not put the drain hose end into water.
Do not put the drain hose end in the drainage ditch.
Fig. [. . . ] Push the hooking claws (9 positions) by hands and fix the claws.
Minus screwdriver Hooking claw
Check that all the hooking claws are fixed to the specified positions.
112
No.
11
Part name
Procedure
Remarks
TE sensor (outdoor heat exchanging temperature sensor) · Attachment Install the sensor onto the straight pipe part of the condenser output pipe.
Arrow D
Detail B Detail A
Detail C for RAS-10SAVR-E, 13SAV-E Detail C for RAS-13-16SAVR-E, 16SAV-E
Detail C
12
TS sensor (Suction pipe temperature sensor) · Attachment Install the senser onto the straight pipe part of the suction pipe. Be careful for the lead direction of the sensor. · Shown in the above figure is the model 13SAVR-E and 16SAV-E. · The sensor mounting positions in the model 10SAVR-E, 13SAV-E and 16SAVR-E are all the same witth the sole exception of the TE sensor. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LW-G0960BCAAFRICA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.