[. . . ] · SUGGESTED TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . · INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 5 5 6
PRECAUTIONS · CAUTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . · GROUNDING INSTRUCTIONS . . . . . . . . . . . [. . . ] In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug.
If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the receptacle box is fully grounded.
3-Pronged receptacle Grounding adapter Grounded receptacle box
3-Pronged plug Grounding prong
Grounded receptacle box Screw Tab for grounding screw
Grounding wire
8
PRECAUTIONS
NOTES ON OPERATION
· Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for protection.
· If a power failure occurs during use, allow 3 minutes before restarting the unit.
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Memories of previous settings will be canceled and the unit will return to each initial setting.
· Dehumidifying function
The air conditioner removes moisture from the air in your room.
· Cooling operation under low temperatures: Is your unit freezing up?
The unit operates on inside and outside temperatures. · SELECTOR indicator and TIMER indicator will light. · The time display will count down the remaining time. · The unit will start when the set time expires. The temperature setting will be displayed.
TO CANCEL THE TIMER SETTING
Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display.
NOTES FOR TIMER SETTING AND OPERATION: · After setting the TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display. · The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function. · If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. · OFF TIMER OPERATION can also be set with the REMOTE CONTROL.
14
HOW TO OPERATE
OFF TIMER OPERATION
· This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time. · The unit will stop automatically according to your setting.
When the unit is operating
1
F hr
POWER
ON/OFF
Touch the TIMER ON/OFF pad to set the delayed stop time.
· The time setting will change as you touch the pad. The display will change as follows;
COOL / FAN
TEMP
ENERGY SAVER
SELECTOR
TIMER
ON/OFF
Preset(0. 5h) Previous setting
0. 5h
1. 0h
1. 5h 12h
10h 11h
CL(cancel)
TIMER ON/OFF pad TIMER indicator
(If you wish to stop the operation 10 hours later, set the delay time as shown above. )
· The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. [. . . ] Rinse carefully by wiping with a damp cloth and dry completely. Excess water can damage electrical insulation and result in danger. Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the unit, do not use hot water (120°F / 50°C or more) when cleaning.
OILING OF THE COMPRESSOR AND FAN MOTOR IS UNNECESSARY
The compressor is permanently lubricated and is hermetically sealed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LW-G0961QC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.