User manual LG LWC1260BCG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LWC1260BCG. We hope that this LG LWC1260BCG user guide will be useful to you.

Lastmanuals help download the user guide LG LWC1260BCG.


Mode d'emploi LG LWC1260BCG
Download
Manual abstract: user guide LG LWC1260BCG

Detailed instructions for use are in the User's Guide.

[. . . ] WIRING DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROL BLOCK DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · A place where the operation noise and discharged air do not disturb your neighbors. 3 Specifications x 3 * To reset to [A] setting, push the [MODE] button again while pushing the [CHK] button. 4 Drain nipple x 1 (Heat pump model only) · A place which is not exposed to a strong wind. · A place which does not block a passage. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. · There must be sufficient spaces for carrying the unit into and out of the site. · A place where the drain water does not raise any problem. 3. Confirm the indoor unit can operate with the changed setting of the remote control. Required tools for installation work 1) Philips screw driver 2) Hole core drill (65 mm) 3) Spanner ­ 45 ­ MODE TEMP . AUTO COOL DRY FAN ONLY FAN AUTO Hr. ON OFF TIMER B C LOW MED. HIGH B C TEMPORARY button TEMPORARY 4) Pipe cutter 5) Knife 6) Reamer 7) Gas leak detector 8) Tape measure 9) Thermometer 10) Mega-tester 11) Electro circuit tester 12) Hexagonal wrench (5 mm) 13) Flare tool 14) Pipe bender 15) Level vial 16) Metal saw CAUTION 1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always to a strong wind like a coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. Specially in windy area, install the unit to prevent the admission of wind. TEMP. START/STOP SET FAN ECONO. Fig. Operate the unit at cooling operation mode for 15 minutes or more. Insert a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A differ from those of refrigerant R22, the flare tools newly manufactured for R410A are recommended. However, the B conventional tools can be used by adjusting projection margin of the copper pipe. 9-3-3 mo 100 re mm fro m wor all 600mm or more ­ 46 ­ 1. Tight connection (between pipes and unit) 3. Evacuate the air in the connecting pipes using VACUUM PUMP. (connected points) * In the case of flaring for R410A with the conventional flare tool, pull out it approx. 0, 5 mm more than that for R22 to adjust to the specified flare size. The copper pipe gauge is useful for adjusting projection margin size. 9-3-7 · Install the provided drain nipple in the hole of the bottom plate. · Perform proper drainage processing using a drain hose sold separately or one on the market. [. . . ] Otherwise it would cause insulation inferiority because of dew drops. 3) When replacing the sensor using the colored protective tube, wind the color tape matching the color of that tube. Remarks Thermal sensor part Cutting here Connector 100 200 Cutting here 15 70 Thermal constringent tube Cutting here 100 15 70 Soldered part Dryer Winding the color tape These are parts for servicing sensors. Please check that the accessories shown in the right table are packed. Parts name 1 2 3 4 5 6 Sensor Sensor Spring (A) Sensor Spring (B) Thermal constringent tube Color tape Terminal Q'ty 1 1 1 3 1 3 Remarks Length : 3m For spare For spare Including one spare 9 colors ­ 77 ­ MCC-758 ­ 78 ­ MCC-775 ­ 79 ­ 12. Indoor Unit (1) RAS-M10, M13YKV-E RAS-M10, M13YKCV-E 407 : RAS-M10YKCV-E 408 : RAS-M13YKCV-E 409 : LWC1260BCG 410 : RAS-M10YKV-E 404 402 412 403 413 405 Location No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LWC1260BCG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LWC1260BCG will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag