User manual LG LWHD7000HR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG LWHD7000HR. We hope that this LG LWHD7000HR user guide will be useful to you.

Lastmanuals help download the user guide LG LWHD7000HR.


Mode d'emploi LG LWHD7000HR
Download
Manual abstract: user guide LG LWHD7000HR

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION 3. 1 HOW TO INSTALL THE UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3. 2 HOW TO DRAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3. 3 HOW TO USE THE REVERSIBLE INLET GRILLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3. 4 WINDOW REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3. 5 INSTALLATION KITS CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3. 6 SUGGESTED TOOL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4. TROUBLESHOOTING GUIDE 4. 1 OUTSIDE DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4. 2 PIPING SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4. 3 TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5. SCHEMATIC DIAGRAM 5. 1 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5. 2 ELECTRONIC CONTROL DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 5. 3 COMPONENTS LOCATION(FOR MAIN P. C. B ASM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5. 4 COMPONENTS LOCATION(FOR DISPLAY P. C. B ASM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 6. EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 7. [. . . ] Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture remaining in the system. With valves A and B closed, stop the vacuum pump. 4) Remove the hose from the vacuum pump and place it on the charging cylinder. Discharge the line at the manifold connection. 5) The system is now ready for final charging. Recharge as follows : 1) Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened. 2) Connect the charging cylinder as shown in Fig. With valve C open, discharge the hose at the manifold connection. 3) Open valve A and allow the proper charge to enter the system. Plastic hose or equivalent may be connected to the drain tube. 1/4 Bubble Level FENCE AWNING FOAM HEAT RADIATION COOLED AIR About 1/2" 30-60" Over 20" 3. 2. HOW TO DRAIN (When using drain pipe) The air conditioner must be installed horizontally or tilted slightly to the outside for proper water drainage. On exceptionally hot and humid days the air conditioner may overflow condensed water. If the air conditioner is used in a hot and high humidity zone, exchange the HOLE RUBBER for the DRAIN PIPE. (See figure 17, figure 18. ) Press the drain pipe into the hole by pushing down and away from the fins to avoid injury BASE PAN 1 HOLE RUBBER hang BOTTOM push BASE PAN BOTTOM 2 DRAIN PIPE 3. 3 HOW TO USE THE REVERSIBLE INLET GRILLE The grille is designed to clean the filter both upward and downward. b A. BEFORE ATTACHING THE FRONT GRILLE TO THE CABINET, IF YOU WANT TO PULL OUT THE FILTER UPWARD; 1. Disassemble the inlet grille from the front grille with separating the hinged part by inserting a straight type screw-driver tip (b). Then, rotate the inlet grille 180 degrees and insert the hooks into bottom holes of the front grille. Insert the filter and attach the front grille to the cabinet. (a) (b) B. IF YOU WANT TO PULL OUT THE FILTER DOWNWARD; The grille is already designed for that way. (c) --12-- 3. 4 WINDOW REQUIREMENTS NOTE: All supporting parts should be secured to firm wood, masonry, or metal. The models of the specific area don't contain installation feit. This unit is designed for installation in standard double hung windows with actual opening widths from 29" to 41". [. . . ] Check the compressor for open circuit or ground. If open or grounded, replace the compressor. Check the compressor overload if externally mounted. (If the compressor temperature is high, remove the overload, cool, and retest. ) Check the voltage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LWHD7000HR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LWHD7000HR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag