User manual LG MB-382W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG MB-382W. We hope that this LG MB-382W user guide will be useful to you.

Lastmanuals help download the user guide LG MB-382W.


Mode d'emploi LG MB-382W
Download
Manual abstract: user guide LG MB-382W

Detailed instructions for use are in the User's Guide.

[. . . ] 3 · PART NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 · USING THE REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . 6 · TIPS ABOUT PLASMACLUSTER OPERATION . . . 7 · BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent. WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery. TIPS ON SAVING ENERGY Below are some simple ways to save energy when you use your air conditioner. SET THE CORRECT TEMPERATURE · Setting the thermostat 1°C higher than the desired temperature in the COOL mode will save approximately 10 percent in power consumption. · Setting the temperature lower than necessary during cooling operation will result in increased power consumption. BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS · Blocking direct sunlight during cooling operation will reduce power consumption. · Close the windows and doors during cooling opeation. SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME · The indoor unit still consumes a small amount of power when it is not operating. 3 PART NAMES INDOOR UNIT 1 2 3 4 5 6 7 8 9 0 q w 1 Inlet (Air) 2 Open Panel 3 AUX. Button 4 Air Filters 5 RECEIVER Window 6 Louvre Unit Open to clean the inside of the air conditioner. 7 Power Supply Cord 8 Indicator Panel 9 Vertical Adjustment Louvres 0 Horizontal Adjustment Louvres q Outlet (Air) w Remote Control e AUTO FAN SPEED Lamp (green ) e r t y u r FAN SPEED Lamp (green t PLASMACLUSTER Lamp (blue, green) y TIMER Lamp (orange u OPERATION Lamp (red ) ) ) OUTDOOR UNIT i o p i Inlet(Air) o Refrigerant Tube and Interconnecting Cord p Drainage Hose a Outlet(Air) a NOTE: Actual units might vary slightly from those shown above. 4 REMOTE CONTROL 1 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 ON/OFF Button MODE TEMP. 2 4 THERMO. (Thermostat) Button 5 DISPLAY Button FAN TIMER TEMP. 3 6 MODE Button 7 TIMER ON Button (for setting the timer) 4 DISPLAY MODE 1h FAN SWING CANCEL 8 ONE-HOUR OFF TIMER Button 9 TIMER OFF Button (for setting the timer) 0 FAN Button q TIMER CANCEL Button w SWING Button e PLASMACLUSTER Button 5 6 7 8 9 0 q w e L. C. D. REMOTE CONTROL DISPLAY r MODE SYMBOLS : AUTO : DRY t FAN SPEED SYMBOLS : AUTO y PLASMACLUSTER SYMBOL u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL o TIMER ON/TIMER OFF INDICATOR Indicates when timer on or timer off is set. : COOL : FAN ONLY r : Manual setting t y u i o 5 USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. the battery cover 1 Removethe remote control. at the back of compartment, 2 Insert batteries in the± and -- making sure the polarities are correctly aligned. · Lines will be indicated on the display when batteries are properly installed. + + 3 Reinstall NOTES: the battery cover. Remote control cover · The battery life is approximately one year in normal use. When fan speed is set to AUTO When fan speed is set to manual Soft speed Low speed High speed The AUTO FAN SPEED Lamp will light up. To turn off the FAN SPEED Lamp, press the DISPLAY button. The PLASMACLUSTER Lamp will also go off. DISPLAY MODE 1h FAN SWING CANCEL 9 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY mode FAN ONLY mode Horizontal air flow Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Press the SWING button on the remote control once. · The vertical adjustment louvre will change its angle continuously. Press the SWING button again when the vertical adjustment louvre is at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time. Adjustment range COOL and DRY mode FAN ONLY mode The adjustment range is narrower the SWING range in order to prevent condensation from dripping. The range is wide so the air flow can be directed toward the floor. HORIZONTAL AIR FLOW DIRECTION Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction. CAUTION Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for the adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre extremely to the right or left when operating the air conditioner with fan speed "SOFT" for an extended period of time. Condensation may form on the louvres. 10 PLASMACLUSTER OPERATION AIR CLEAN OPERATION : Cluster ions released into air will reduce airborne mold fungus and deodorize/decompose odor-causing molecules. REFRESHING OPERATION : Negative ions will be released in an increased rate. 1 MODE TEMP. During operation, press the PLASMACLUSTER button to select the mode. AIR CLEAN REFRESHING CANCEL FAN TIMER DISPLAY MODE 1h FAN SWING CANCEL · In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. · In the REFRESHING operation, the green PLASMACLUSTER lamp on the unit will light up. TO CANCEL 1 NOTE: Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off. · The PLASMACLUSTER lamp on the unit will turn off. · Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner. [. . . ] In such case, reinstall the louvre unit properly. Push the ON/OFF button of the remote control and check if the unit operates properly. 14 MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. CLEANING THE FILTERS The air filters should be cleaned every two weeks. 1 TURN OFF THE UNIT 2 REMOVE THE FILTERS 1 2 3 1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG MB-382W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG MB-382W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag