[. . . ] 3 · PART NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 · USING THE REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . 6 · TIPS ABOUT PLASMACLUSTER OPERATION . . . 7 · BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
· Setting the thermostat 1°C higher than the desired temperature in the COOL mode will save approximately 10 percent in power consumption. · Setting the temperature lower than necessary during cooling operation will result in increased power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
· Blocking direct sunlight during cooling operation will reduce power consumption. · Close the windows and doors during cooling opeation.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
· The indoor unit still consumes a small amount of power when it is not operating.
3
PART NAMES
INDOOR UNIT
1 2 3 4 5 6 7 8 9 0 q w 1 Inlet (Air) 2 Open Panel 3 AUX. Button 4 Air Filters 5 RECEIVER Window 6 Louvre Unit Open to clean the inside of the air conditioner. 7 Power Supply Cord 8 Indicator Panel 9 Vertical Adjustment Louvres 0 Horizontal Adjustment Louvres q Outlet (Air) w Remote Control
e AUTO FAN SPEED Lamp (green ) e r t y u r FAN SPEED Lamp (green t PLASMACLUSTER Lamp (blue, green) y TIMER Lamp (orange u OPERATION Lamp (red ) ) )
OUTDOOR UNIT
i o p
i Inlet(Air) o Refrigerant Tube and Interconnecting Cord p Drainage Hose a Outlet(Air)
a
NOTE: Actual units might vary slightly from those shown above.
4
REMOTE CONTROL
1 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 ON/OFF Button
MODE
TEMP.
2 4 THERMO. (Thermostat) Button 5 DISPLAY Button
FAN
TIMER TEMP.
3
6 MODE Button 7 TIMER ON Button (for setting the timer)
4
DISPLAY MODE 1h FAN SWING CANCEL
8 ONE-HOUR OFF TIMER Button 9 TIMER OFF Button (for setting the timer) 0 FAN Button q TIMER CANCEL Button w SWING Button e PLASMACLUSTER Button
5 6 7 8 9 0 q w e
L. C. D. REMOTE CONTROL DISPLAY
r MODE SYMBOLS : AUTO : DRY t FAN SPEED SYMBOLS : AUTO y PLASMACLUSTER SYMBOL u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL o TIMER ON/TIMER OFF INDICATOR
Indicates when timer on or timer off is set.
: COOL : FAN ONLY r : Manual setting t
y u i
o
5
USING THE REMOTE CONTROL
LOADING BATTERIES Use two size-AAA (R03) batteries.
the battery cover 1 Removethe remote control. at the back of compartment, 2 Insert batteries in the± and -- making sure the polarities are correctly aligned. · Lines will be indicated on the display when batteries are properly installed.
+ +
3 Reinstall
NOTES:
the battery cover.
Remote control cover
· The battery life is approximately one year in normal use. When fan speed is set to AUTO When fan speed is set to manual Soft speed
Low speed
High speed
The AUTO FAN SPEED Lamp will light up.
To turn off the FAN SPEED Lamp, press the DISPLAY button.
The PLASMACLUSTER Lamp will also go off.
DISPLAY MODE 1h FAN SWING CANCEL
9
ADJUSTING THE AIR FLOW DIRECTION
VERTICAL AIR FLOW DIRECTION
The air flow direction is automatically preset in each mode as follows for optimum comfort:
COOL and DRY mode FAN ONLY mode
Horizontal air flow Diagonal air flow
HOW TO ADJUST THE AIR FLOW DIRECTION
Press the SWING button on the remote control once. · The vertical adjustment louvre will change its angle continuously. Press the SWING button again when the vertical adjustment louvre is at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time.
Adjustment range
COOL and DRY mode FAN ONLY mode
The adjustment range is narrower the SWING range in order to prevent condensation from dripping.
The range is wide so the air flow can be directed toward the floor.
HORIZONTAL AIR FLOW DIRECTION
Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction.
CAUTION
Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for the adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre extremely to the right or left when operating the air conditioner with fan speed "SOFT" for an extended period of time. Condensation may form on the louvres.
10
PLASMACLUSTER OPERATION
AIR CLEAN OPERATION : Cluster ions released into air will reduce airborne mold fungus and deodorize/decompose odor-causing molecules. REFRESHING OPERATION : Negative ions will be released in an increased rate.
1
MODE TEMP.
During operation, press the PLASMACLUSTER button to select the mode.
AIR CLEAN REFRESHING CANCEL
FAN
TIMER
DISPLAY MODE 1h FAN SWING CANCEL
· In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. · In the REFRESHING operation, the green PLASMACLUSTER lamp on the unit will light up.
TO CANCEL
1
NOTE:
Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off.
· The PLASMACLUSTER lamp on the unit will turn off.
· Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner. [. . . ] In such case, reinstall the louvre unit properly. Push the ON/OFF button of the remote control and check if the unit operates properly.
14
MAINTENANCE
Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.
CLEANING THE FILTERS
The air filters should be cleaned every two weeks.
1 TURN OFF THE UNIT 2 REMOVE THE FILTERS
1 2 3
1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG MB-382W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.