[. . . ] When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. [. . . ] Set connector aside - with mounting screws and parts bag. DAMPER/ DUCT CONNECTOR
8
Remove Baffle from air chute.
BAFFLE BAFFLE
5
Remove either top or back wiring knockout and install approved Electrical Cable Clamp.
ELECTRICAL CABLE CLAMP 9 Rotate baffle. Reinsert baffle into air chute (as shown) so that baffle tabs fit all the way into slots in air chute. An audible "click" will be heard when fully installed. This will close off the air flow through the non-ducted slots on top of hood.
Non-Ducted Installation - Skip to Step 15.
(3) #8 SCREWS
SLOTS
TABS
10 6 Remove Light Panel - held in place with (3) #8 screws and (2) #8 screws. Disconnect light assembly wire harness (white connector).
3
Re-install air chute, re-connect wire harness, and replace light panel. NOTE: Be careful not to trap wires between support fin and light panel. SUPPORT FIN
The following Steps (6 thru 14) are for DUCTED INSTALLATION ONLY.
(2) #8 SCREWS
LIGHT PANEL
PREPARE THE HOOD
TOP RECTANGULAR DUCT KNOCKOUT (Remove for 3¼" x 10" Vertical & for 7" Round Discharge) SEMI-CIRCULAR DUCT KNOCKOUT (Remove for 7" Round Discharge)
PREPARE THE HOOD
TAPE UP TO 1" SIDE-TO-SIDE ADJUSTMENT TOP/BACK EDGE
DAMPER/ DUCT CONNECTOR (Vertical discharge position shown)
PIVOT REAR RECTANGULAR DUCT KNOCKOUT (Remove for 3¼" x 10" Horizontal Discharge) 11 Remove appropriate Duct Knockout(s) from top or back of hood. 14
13
3¼" x 10" Ducted Discharge Only: Remove Tape from damper flap and attach Damper/Duct Connector over knockout opening with screws removed in Step 4 under "PREPARE THE HOOD". Make sure damper Pivot is nearest to Top/Back Edge of hood. 7" Round Ducted Discharge Only: Re-install 7" Round Duct Plate removed in Step #1 under "PREPARE THE HOOD". These speeds provide the most efficient and quiet operation during cooking, while maximizing the benefits of the recirculating filtration system.
OPERATION
Fan and Lights: 3 push button switches for each. Push any button to select one of 3 fan speeds or one of 3 light levels. Push the same button to turn fan or light off. Press another button to change fan speed or light level. A light above each fan button indicates the fan speed. Heat Sentry: Your range hood is equipped with the Heat Sentry feature, which monitors temperature. The Heat Sentry will automatically turn the fan on at its highest speed when the temperature is above normal. 1) If a fan setting is selected when the Heat Sentry in on, the light above the fan button will flash on and off. 2) If the fan setting is off when the Heat Sentry is on, the light above fan button 3 will flash on and off rapidly. After the temperature has lowered to normal, the fan will change to the setting prior to the Heat Sentry turning on. Fuse: The hood control contains a fuse to protect it from power surges. [. . . ] Do not use abrasive cloth, steel wool pads, or scouring powder on the Teflon®-coated bottom cover or on any painted surface. Use care when cleaning blower wheel - it must not become bent or misaligned. Make sure all surfaces are completely dry before re-installing filters and restoring power. Teflon® is a registered trademark of DuPont.
6
SERVICE PARTS
KEY NO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG MD-278GT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.