[. . . ] Visit us at : http://www. lgservice. com
LG
ENGLISH
LG AHU CONTROL KIT
Owner's Manual
Models: PRCKD20E PRCKD40E
ITALIANO ESPAÑOL FRANÇAIS PORTUGUESE
IMPORTANT
· Please read this installation manual completely before installing the product. · Installation work must be performed in accordance with the national wiring standards by authorized personnel only. · Please retain this installation manual for future reference after reading it thoroughly.
AHU CONTROL KIT Owner's Manual
TABLE OF CONTENTS
I Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 I Necessary sensor by operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 I Part Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 I Basic operation of wired remote controller. . . . . . . . . . . . . . . . . . . . . . . . . . 8 I Main function of wired remote controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 I Supplementary function of wired remote controller . . . . . . . . . . 11
I Humidifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 I Desired humidity control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 I Auto ventilaton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 I Desired CO2 level control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 I Changing Current Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 I Programming : Setting Simple Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 I Programming : Setting ON Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 I Programming : Setting OFF Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 I Programming : Weekly Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 I Programming : Holiday Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 I How to start installation setting mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 I Setting function by code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 I Central control address setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 I Damper opening setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 I Remote control Master/Slave setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 I SA fan operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 I RA fan operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
I Reservation function of wired remote controller . . . . . . . . . . . . . . . 15
I Setting function of wired remote controller installation . . . . . 23
I Manual operating mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
I Check before requesting for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 I Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
I Self diagnosis function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2 AHU CONTROL KIT
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. [. . . ] - This is the operating function to control the amount of external air flow so that the CO2 level is controlled within the set level by detecting the indoor CO2 level. - The initial CO2 level is set to 1000ppm, and can be changed by the user. - This function operates when auto ventilator (Additional operation) is selected during air conditioning or heating operation. But if there is no CO2 sensor and damper actuator on the AHU, the auto ventilator operation cannot be selected. - When the mixing temperature during the heating operation is below the set value (5°C), preheating device automatically operates. The preheating device and mixing temperature sensor must be installed on AHU for this to operate automatically. Air conditioning
Heating
SA temperature sensor RA temperature sensor
Power save
SA temperature sensor RA temperature sensor OA temperature/ humidity sensor Damper actuator
Dehumidify
SA temperature sensor RA temperature sensor OA temperature/ humidity sensor
Humidification
SA temperature sensor RA temperature sensor
Auto ventilation
SA temperature sensor RA temperature sensor CO2 sensor Damper actuator
Preheating
SA temperature sensor RA temperature sensor Mixing temperature/ humidity sensor
6 AHU CONTROL KIT
Part Description
Part Description
Name and Function of Remote Controller ENGLISH
1 OPERATION INDICATION SCREEN 2 SET TEMPERATURE Button 3 WIRELESS REMOTE CONTROLLER RECEIVER · Some products don't receive the wireless signals. 4 VENTILATION Button 5 OPERATION MODE SELECTION Button 6 SUBFUNCTION Button 7 FUNCTION SETTING Button 8 EXIT Button 9 ON/ OFF Button 10 ROOM TEMPERATURE Button 11 RESET Button 12 FAN SPEED Button 13 AIR FLOW Button 14 RESERVATION/ TIME SETTING Button 15 SETTING/ CANCEL Button 16 UP, DOWN, LEFT, RIGHT Button
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Please attach the inform label inside of the door. Please choose proper language defend on your country.
· 3/4/12/13 does not work. · 6 Additional operation button depends on the application of the sensor.
Owner's Manual 7
Basic operation of wired remote controller
Basic operation of wired remote controller 1 Press the Run/Stop button on the control part of the remote controller to start the
operation.
2 Press the Operation Selection button to set the operating mode (Heating/Cooling
etc. ).
3 Press the Temperature Control button to set the desired temperature below the
indoor temperature. (Based on air conditioning operation) (Example) Remote controller display window
L Indoor temperature
L Desired temperature
During the initial operation, the desired temperature is automatically set below the indoor temperature. the Run/Stop button 4 When you pressoperation will stop. during use, the
8 AHU CONTROL KIT
Main function of wired remote controller
Main function of wired remote controller
you press the Run/Stop 1 Every time ON and OFF will be button, the repeated.
ENGLISH
Selection 2 Every time you pressinthe Operation Air button, it will change the order of Conditioner ¡æ Dehumidifier ¡æ Heater ¡æ Power Save ¡æ Fan. 3 Press the Up/Down button to set the target CO2 level.
4 Press the OK/CLEAR button to set the target CO2 level.
* Desired CO2 level can be controlled in the range of 500~1500ppm by 100ppm increment. * Default humidity is set to 1000ppm.
Display C: CO2 level
Function Code
Setting
(Function set by code) * Code 02: Desired CO2 level : Desired CO2 level (Example)
<Desired CO2 level: 500ppm>
14 AHU CONTROL KIT
Reservation function of wired remote controller
Reservation function of wired remote controller
Changing Current Time
ENGLISH
pressing button for 1 Keepto enter Setting current 4 secs time mode. Ex) Changing Current Time as 'Monday / AM 10:20'.
2 Press day.
key to adjust the current
move to AM/ PM setting 3 Press (the key toPM segment will flash). mode 'AM/
4 Setting AM/ PM value by pressing button.
button to 'Hour' 5 Press mode. (theto movesegment will setting 'Hour' flash)
6 Setting Hour value by pressing button.
Owner's Manual 15
Reservation function of wired remote controller
button 7 Press mode. (theto move to 'Minute'will setting 'Minute' segment flash)
8 Setting Minute value by pressing button.
9 Press 10
button to finish.
In the process, press button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting )
16 AHU CONTROL KIT
Reservation function of wired remote controller
Programming : Setting Simple Reservation
In case of there is not any reservation setup on system, it is possible to make a SIMPLE reservation on indoor unit.
ENGLISH
1 Press button to enter the Programming mode.
(the segment flashing) Ex) Setting Simple Reservation time as '3'. to adjust reservation
3 Press
button to finish setting.
4 Adjusting the reservation time after finish reservation setting will release the
previous one.
If the indoor is ON, we can make the reservation for turning OFF. In reserve, if the indoor is OFF,
we can set the timer for turning ON. [. . . ] repeatedly to reach function code
Flashes
3 Press the Right button to move to `Setting of 1'.
Flashes button 4 Press the Up/Down is to set the value. Setting value of `01' the Master and `00' is the Slave. Master
Slave OK/CLEAR 5 Press the the setting. button to complete * This is the function to set the mainly used remote controller. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG PRCKD40E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG PRCKD40E will begin.