User manual LG R1003

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG R1003. We hope that this LG R1003 user guide will be useful to you.

Lastmanuals help download the user guide LG R1003.


Mode d'emploi LG R1003
Download
Manual abstract: user guide LG R1003

Detailed instructions for use are in the User's Guide.

[. . . ] You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. PRECAUTION · Contact the authorized service technician for repair or maintenance of this unit. · Contact the installer for installation of this unit. · The air conditioner is not intended for use by young children or invalids without supervision. [. . . ] There is a possibility of injury if the unit's power is accidentally triggered on while cleaning inner parts of the unit. Service For repair and maintenance, contact your authorized service dealer. 8 Single Package Type Air Conditioner Operating Instructions Operating Instructions Name and Function of Remote Controller ENGLISH AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 Heat Pump Model 1 Time Timer Operation unit 03 05 07 Program set 09 11 13 15 On Off Set no. Time 01 3 Signal receptor 2 9 8 4 5 6 7 8 17 Cooling Model 10 12 14 15 Hour Min RESET 11 13 Timer Cancel Program Week Holiday SET/CLR 16 1 Operation display Displays the operation conditions. 2 On/Off Button Operation starts when this button is pressed, and stops when the button is pressed again. 3 Set Temperature Button Used to set the temperature when the desired temperature is obtained. 4 Fan Operation Button Used to circulate room air without cooling or heating. 5 Fan Auto Button(Cooling Only) 8 Room Temperature Checking Button Used to check the room temperature. 9 Heater Button 10 Timer Cancel Button Used to cancel the timer. 11 Timer Set Button Used to set the timer when the desired time is obtained. 12 Week Button Used to set a day of the week. 13 Program Button Used to set the weekly timer. 14 Holiday Button Used to set a holiday of the week. Time 01 Cooling Operation Soft Dry Operation 3 Set the temperature lower than the room temperature. AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 · The temperature can be set within a range of 18°C ~ 30°C by 1°C . Time Timer Operation unit 03 05 07 Program set 09 11 13 15 On Off Set no. To lower the Temperature. Owner's Manual 15 Operating Instructions Soft Dry Operation Mode This mode dehumidifies without overcooling. 1 Press the On/Off Button. 2 Select Soft Dry Operation. Press the operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. HEAT PUMP MODEL Operation Display AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 Time Timer Operation unit 03 05 07 Time Timer Operation unit 03 05 07 Time Timer Operation unit 03 05 07 Program set 09 11 13 15 17 19 21 23 Program set 09 11 13 15 17 19 21 23 Program set 09 11 13 15 On Off Set no. Time 01 Cooling Operation Soft Dry Operation Heating Operation COOLING MODEL Operation Display AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 Time Timer Operation unit 03 05 07 Time Timer Operation unit 03 05 07 Program set 09 11 13 15 17 19 21 23 Program set 09 11 13 15 On Off Set no. Time 01 Cooling Operation Soft Dry Operation 16 Single Package Type Air Conditioner Operating Instructions Heating Operation Mode(Heat pump model only) 1 Press the On/Off Button. ENGLISH 2 Select Heating Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. Operation Display AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 Time Timer Operation unit 03 05 07 Time Timer Operation unit 03 05 07 Time Timer Operation unit 03 05 07 Program set 09 11 13 15 17 19 21 23 Program set 09 11 13 15 17 19 21 23 Program set 09 11 13 15 On Off Set no. Time 01 Cooling Operation Soft Dry Operation Heating Operation · The temperature can be set within a range of 16°C~30°C by 1°C. 3 Set the temperature. AUTO SWING OPERATION SET TEMP Room Temp SUB FUNCTION HI MED LO AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234 17 19 21 23 Time Timer Operation unit 03 05 07 Program set 09 11 13 15 On Off Set no. To lower the Temperature. 4 This air-conditioner is set to the hot start control in order not to discharge the cold air during the heating operation. [. . . ] Operate the air conditioner on Air circulation mode for 2 to 3 hours. · This will dry out the internal parts. Turn off the circuit breaker. ENGLISH CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. When the air conditioner is to be used again. 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG R1003

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG R1003 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag