[. . . ] 6 Indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
OPERATION
I DRY · COOL · FAN Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 I POWERFUL Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 I Adjusting the Air Flow Direction Adjusting the horizontal blade (flap) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · When the unit receives a signal, you will hear a short beep.
· In the case of multi system operation, there are times when the unit does not activate with this button. )
4
Names of Parts
Outdoor unit
Air inlet
(Back and side)
Refrigerant piping and inter-unit cable
Air outlet
Drain hose Earth terminal
It is inside of this part.
Appearance of the outdoor unit may differ with some models.
Remote controller
<CS-MK90/120>
Transmitter
sends signals to the indoor unit.
Display Open the cover.
displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation. Some models may not show all its indications. )
OFF/ON
ON/OFF button
Press it once to start operation. To stop it, press it once again.
ON
TEMP
TEMPERATURE/TIME adjustment buttons
change the temperature or time setting.
C
AMPM
TIME
OFF-TIMER CLOCK ON-TIMER CANCEL
CLOCK button
(See page 7 "Preparation Before Operation - Setting the Clock)
OFF TIMER button ON TIMER button
(See page 10 "Timer Operation")
AMPM
FAN SPEED MODE
TIMER CANCEL button
cancels the timer setting.
MODE selector button
selects the operation mode.
: DRY : COOL : FAN
SWING POWERFUL
FAN setting button
selects the air flow rate setting.
SWING button
(See page 9 "Adjusting the Air Flow Direction")
POWERFULL button
(See page 8 "POWERFUL Operation")
ARC417A24 <CS-MK180>
MODE SWING POWERFUL
SWING button
(See page 9 "Adjusting the Air Flow Direction")
ARC417A25
5
Preparation Before Operation
Remote controller
Setting the batteries
Position and correctly!Address switch
Operating the remote controller
· To use the remote controller, aim the transmitter at the indoor · ·
unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate. The maximum distance for communication is about 7 m.
2
Receiver
3 1
1 2 3·
Press with a finger and slide the back cover to take it off. Set the back cover as before.
This will cause the figures on the display to flash. Set the clock at this point.
To fix the remote controller holder on the wall
1 2 3
Choose a place from where the signals reach the unit. Fix the holder to a wall, a pillar, etc. Moreover, for precedence-room settings, please consult your dealer or service shop.
I To change the temperature setting:
DRY or FAN mode Press The temperature setting is not variable. COOL mode to raise the temperature and press to lower the temperature. Set to the temperature you like.
C
POWERFUL Operation
POWERFUL operation quickly maximizes the cooling effect in any operation mode. You can get the maximum capacity with a touch of a button.
· Pressing the (POWERFUL) button during operation starts POWERFUL operation. · POWERFUL operation ends in 20 minutes. Then the system
automatically operates again with the settings which were used before POWERFUL operation.
Press
FAN SPEED
.
COOL or FAN mode
Press
.
DRY mode The air flow rate setting is not variable.
I To cancel POWERFUL operation:
" to
Five levels of air flow rate setting from " " " plus " " are available.
Press
POWERFUL
.
Display
Notes on POWERFUL operation
· In COOL mode · At smaller air flow rates, the cooling or heating effect is also
smaller.
· ·
8
To maximize the cooling and heating effect, the capacity of outdoor unit must be increased and the air flow rate be fixed to the maximum setting. The temperature and air flow settings are not variable. In DRY mode The temperature setting is lowered by 3°C and the air flow rate is slightly increased. In FAN mode The air flow rate is fixed to the maximum setting.
Display
I To change the air flow rate setting:
Display
1
POWERFUL
Adjusting the Air Flow Direction
You can adjust the air flow direction to increase your comfort.
Adjusting the louvre
<CS-MK90/120>
Adjusting the horizontal blade (flap)
Press
SWING
.
" appears or
· Every time the button is pressed, "
disappears.
. . . . . . . The flap automatically
swings up and down.
. . . . . . . To stop the flap at an
angle you like, press No display
SWING
.
Hold the knob and move the louvre. [. . . ] I For system protection, the air conditioner may stop operating on a sudden large voltage fluctuation. It automatically resumes operation in about 3 minutes.
Mists come out of the indoor unit. The indoor unit gives out odour.
The outdoor fan rotates while the air conditioner is not in operation.
The operation stopped denly. (OPERATION lamp is on)
sud-
13
Trouble Shooting
Check again Please check again before calling a repair person.
Case
The air conditioner does not operate. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG R400-EP01A9
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.