User manual LG S246KC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG S246KC. We hope that this LG S246KC user guide will be useful to you.
Lastmanuals help download the user guide LG S246KC.
Manual abstract: user guide LG S246KC
Detailed instructions for use are in the User's Guide.
[. . . ] E 58 ~ 65 , .
ESPAÑOL 18 ~ 25 Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. NEDERLANDS 42 ~ 49 Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik. 66 ~ 73 , .
QUICK GUIDE / GUIDE RAPIDE GUÍA RÁPIDA / KURZANLEITUNG GUIDA RAPIDA / SNELLE GIDS GUA RÁPIDO / YNTOMO OHO
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Unauthorized copying and distribution is a violation of law.
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
DEFINITION The instructions to be followed are classified by the following symbols:
This symbol denotes an action that is PROHIBITED. [. . . ] Penalties may also be applicable for incorrect disposal of waste products, in accordance with national legislation. *subject to the national law of each member state Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal. · Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit. · Do not install the unit in oily and smoky areas. 3
ENGLISH
OPERATION CONDITION OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range (CU-E15HKE, CU-E15HKE-1) Temperature (°C) COOLING HEATING Maximum Minimum Maximum Minimum Indoor *DBT 32 16 30 16 *WBT 23 11 *DBT 43 16 24 -5 Outdoor *WBT 26 11 18 -6
NOTICE: · This model is not suitable for continuous operation in heat mode below -5°C (24 hours operation). If you use this model under the above conditions, the outdoor unit might be frozen up and stop operation. · When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control. (CU-2E15GBE, CU-2E18CBPG, CU-3E18EBE, CU-3E23CBPG, CU-4E27CBPG) Temperature (°C) COOLING HEATING * DBT: Dry bulb temperature * WBT: Wet bulb temperature Maximum Minimum Maximum Minimum Indoor *DBT 32 16 30 16 *WBT 23 11 *DBT 43 16 24 -10 Outdoor *WBT 26 11 18 -11
4
MULTI AIR CONDITIONER FUNCTION MULTI AIR CONDITIONER FUNCTION
(CU-2E15GBE, CU-2E18CBPG, CU-3E18EBE, CU-3E23CBPG, CU-4E27CBPG) DEFINITION Multi air conditioner system has one outdoor unit connected to multiple indoor units.
INDOOR UNIT
· It is possible to operate the indoor units individually or simultaneously. · The operation mode priority is given to the first unit that turned on. · When the air quality is unsatisfactory, e-ion operation will start automatically. TO ENJOY QUIET ENVIRONMENT · This operation reduces airflow noise. TO ACHIEVE TEMPERATURE QUICKLY Select ON or OFF timer. or then
· To cancel ON or OFF timer, press press .
· When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time. · Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. · If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing .
OPTIONAL SETTINGS
Patrol starts automatically with the unit . switched on with Press and hold for 5 seconds, then release to disable or restore this setting. Press and hold for 5 seconds to dim or restore the unit's indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication. [. . . ] · Wash/rinse the filters gently with water to avoid damage to the filter surface. · Dry the filters thoroughly under the shade, away from fire or direct sunlight. · Replace any damage filter.
ACTIVE e-ion POWER MODULE
FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
· Checking of remote control batteries. · No obstruction at air inlet and air outlet vents. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG S246KC Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG S246KC will begin.