[. . . ] Use this appliance on a dedicated circuit.
· There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
· Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
· There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
· There is risk of fire or electric shock.
Always install a dedicated circuit and breaker.
· Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
· There is risk of fire or electric shock.
Owner's Manual 3
Safety Precautions
Do not modify or extend the power cable.
· There is risk of fire or electric shock.
Do not install, remove, or reinstall the unit by yourself (customer).
· There is risk of fire, electric shock, explosion, or injury.
Be cautious when unpacking and installing the product.
· Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the dealer or an Authorized Service Center.
· There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
· It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
· If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
I Operation
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
· Moisture may condense and wet or damage furniture.
Take care to ensure that power cable could not be pulled out or damaged during operation.
· There is risk of fire or electric shock.
Do not place anything on the power cable.
· There is risk of fire or electric shock.
Do not plug or unplug the power supply plug during operation.
· There is risk of fire or electric shock.
Do not touch(operate) the product with wet hands.
· There is risk of fire or electrical shock.
Do not place a heater or other appliances near the power cable.
· There is risk of fire and electric shock.
4 Floor Standing-Type Air Conditioner
Safety Precautions
Do not allow water to run into electric parts.
· It may cause There is risk of fire, failure of the product, or electric shock.
Do not store or use flammable gas or combustibles near the product.
· There is risk of fire or failure of product.
Do not use the product in a tightly closed space for a long time.
· Oxygen deficiency could occur.
Gasolin
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
· Do not use the telephone or turn switches on or off. There is risk of explosion or fire
If strange sounds, or small or smoke comes from product. [. . . ] Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit's power is triggered while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
Introduction
Symbols used in this Manual
This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner.
NOTICE
This symbol indicates special notes.
8 Floor Standing-Type Air Conditioner
Operating Instructions
Operating Instructions
Features
1 Design for cooling & Heating 2 Super energy efficiency 3 Micom control 4 Whisper quiet operation 5 Wireless remote control 6 2 cooling speeds 7 Removable air filter 8 Anti-Bacteria filter 9 3 minutes delay circuit 10 Jet Cool(Turbo-Z) operation 11 Energy saving 12 Auto restart 13 Plasma Air Purifying system
(KC* MODEL)
Specifications
Air Outlet Vent Remote Signal Receptor Air Intake Vent (Rear)
Air Intake Vent
Air Outlet Vent
Owner's Manual 9
Operating Instructions
Indoor Unit Controls and Indicators
13
7 6
8
19 18
14
12 11
13
9 6
8
14
12 11
A/CL
JET COOL
ROOM SET
A/CL
JET COOL
ROOM SET
10
A Mode Temp. Fan Speed On/Off
10
16
2
15
5
17
3
1
4
2
15
5
17
3
1
Notice Fan Heat pump KA* MODEL Air Cleaner Heat pump KC* MODEL Electric Heater Z MODEL
A
(Z, Heat Pump Model)
1 START/STOP BUTTON
(Cooling Model)
10 JET COOL(TURBO-Z) OPERATION LAMP 11 ENERGY SAVING OPERATION LAMP 12 OFF TIMER OPERATION LAMP 13 FAN OPERATION LAMP(KA* MODEL) 14 AUTO AIRFLOW OPERATION
LAMP(VERTICAL)
Operation starts when this button is pressed and stops when the button is pressed again.
2 OPERATION MODE SELECTION BUTTON
Used to select the operation Mode.
3 INDOOR FAN SPEED SELECTION Used to select fan speed in two steps-low, high. 4 FAN OPERATION BUTTON
Used to circulate room air without cooling.
15 TELE-CONTROL OPERATION LAMP
(OPTIONAL)
5 ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
16 FAN OPERATION BUTTON
(HEAT PUMP KA* MODEL) AIR CLEANER OPERATION BUTTON (HEAT PUMP KC* MODEL) ELECTRIC HEATER BUTTON(Z MODEL)
6 COOLING OPERATION LAMP 7 HEATING OPERATION LAMP 8 SOFT DRY OPERATION LAMP 9 AUTO OPERATION LAMP
17 AIR CLEANER OPERATION LAMP
(KC* MODEL)
18 ELECTRIC HEATER OPERATION LAMP
(Z MODEL)
19 DEFROST OPERATION LAMP
10 Floor Standing-Type Air Conditioner
Operating Instructions
Name and Function-Remote Control
1 2
A/CL
14 8
2 4 3 15 5 6 7 13
14 8 9 10 11 12
3 15 6 7
9 4 10 11 12
(Z, H/P, KC* Model)
1 2 8
A/CL
(Z, H/P, KA* Model)
2 4 3 15 5 6 7 13 8 9 10 11 12
3 15 6 7
9 4 10 11 12
(C/O, KC* Model)
(C/O, KA* Model)
1
Signal Transmitter · Transmits the signals to the Floor Standing Type air conditioner
8 9
Cooling ON Button Heating Button (Heat Pump Model Only) Auto Operation Button(Cooling Model Only)
2 Operation Display of the Remote Control 3 Timer Set Button · Each time the button is pressed, the mode is changed in the following process. Timer set (1, 2, 3, 4, 5, 6, 7 hours) If you select "0:00" the off Timer function will be canceled. 4
10 Soft Dry Operation Button 11 Energy Saving Operation Button 12 Power ON/OFF Button · Operation will start when this button is pressed, and stop when the button is pressed again. 13 Temperature Setting Buttons 14 Electric Heater ON/OFF Button(Z Model) 15 Auto Airflow Direction control Button(Not available) · The horizontal louvers swing low and high.
Plasma Air Purifying Button(KC* MODEL) Fan Operation Button(KA* MODEL)
5 Auto Airflow Direction Control Button · The vertical louvers swing left and right. All the key on the indoor unit Touch panel will not work. But the key on the remote controller will work.
fan speed simultaneously 3 Press thewill respondand high temperature setting buttons removed. The unit with beep, Child Lock Operation will
Temp. Fan Speed
For releasing child lock operations
After pressing the buttons it will shifted immediately
After 3 seconds, it will shifted.
A/CL
JET COOL
ROOM SET
A/CL
JET COOL
ROOM SET
A/CL
JET COOL
ROOM SET
24 Floor Standing-Type Air Conditioner
Maintenance and Service
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to the system.
During the season
Cleaning of the air filters. Recommended about once every two weeks
Remove the Air Filter. Take hold of the tab and pull slightly forward to remove the filter. · To remove the dust adhering to the filters, either use a vacuum cleaner, or wash them in water and dry in the shade. · Re-insert the filter to the original position.
Cleaning of the air cleaner. Recommended about once every three months
Remove the Air Cleaner. Take hold of the tab and pull slightly forward to remove the air cleaner. · Dip the air cleaner into the water mixed with detergent, for 20~30 minutes, and dry in the shade. [. . . ] · Condensation occurs when the airflow from the air conditioner cools the warm room air. · This is the Protection device of the air conditioner . · Wait about three minutes and operation will begin. · If the airflow begins before its temperature become warm, it will cause an undesired cooling effect. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG SV12A10A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.