User manual LIFT-MASTER 71 909206 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER 71 909206 1. We hope that this LIFT-MASTER 71 909206 1 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER 71 909206 1.


Mode d'emploi LIFT-MASTER 71 909206 1
Download
Manual abstract: user guide LIFT-MASTER 71 909206 1

Detailed instructions for use are in the User's Guide.

[. . . ] DELAY-ON-REVERSE 1PH Modification, K-Line 71-9092061 APPLICATION REQUIREMENTS: This modification is available to models T, GT, J, H, GH, SD and GSD standard door operators with 24V control circuits. This modification is standard on Model GH-300. [. . . ] Locate the IR (instant reverse) relay-line voltage coil with 6 wires: 2 black, 1 red, 1 purple, 1 orange and 1 yellow. Exchange this relay with the 3PDT relay provided. Be sure that the new relay has the same coil voltage as the existing relay. Connect the wires from the original relay to the new relay (refer to figure 1). Install an orange jumper from the common (C) terminal of the TD relay, that corresponds to the yellow wire, to the normally open (NO) terminal of the IR relay where the yellow wire was. Unplug the red wire from the IR relay and plug it into the normally closed (NC) terminal of the TD relay. Install a purple jumper from the common (C) terminal of the TD relay, that corresponds to the red wire, to the normally open (NO) terminal of the IR relay where the red wire was. Plug the TD module onto the two coil terminals of the TD relay. Connect the white into the wire nut that contains at least 3 wires (1 yellow from transformer, 1 orange from open limit and 1 purple from close limit there may also be one or two red wires in this wire nut). Be sure the other wires al remain in the wire nut. 8. . Connect the orange wire to the center of the normally closed (NC) terminal of the IR relay. Connect the blue wire from terminal 3 to the center common (C) of the IR relay - this terminal corresponds to the orange to the orange wire just installed that came from the TD module. [. . . ] Use figure 2 to assist with the rest of the installation instructions. Unplug the yellow wire from the IR relay and plug it into the normally closed (NC) terminal of the TD relay. TERMINAL #3 NEW PURPLE JUMPER PURPLE RED FROM IR BLACK BLUE NC NO C COIL EXISTING WIRE NUT WHITE IR RELAY TD RELAY NC NO C COIL TD MODULE NC NO C BLACK ORANGE YELLOW FROM IR NEW ORANGE JUMPER ORANGE 01-11721D © 1998, The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 71 909206 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 71 909206 1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag