Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER 90 5024. We hope that this LIFT-MASTER 90 5024 user guide will be useful to you.
Lastmanuals help download the user guide LIFT-MASTER 90 5024.
Detailed instructions for use are in the User's Guide.
[. . . ] DO NOT INSTALL CONTROL STATION DIRECTLY BENEATH THE OPERATOR. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A SAFETY DEVICE MUST BE INSTALLED ON THE DOOR, THE MINIMUM ACCEPTABLE DEVICE WOULD BE SAFETY PHOTO EYES, OR A REVERSING EDGE INSTALLED ON THE BOTTOM OF THE DOOR. THE BEST PROTECTION IS AFFORDED BY THE COMBINATION OF THESE TWO DEVICES.
W
TION NING
WARNING
CAUTION
WARNING
ANY MAINTENANCE TO THE OPERATOR OR IN THE AREA NEAR THE OPERATOR MUST NOT BE PERFORMED UNTIL DISCONNECTING THE ELECTRICAL POWER. UPON COMPLETION OF MAINTENANCE THE AREA MUST BE CLEARED AND SECURED, AT THAT TIME THE UNIT MAY BE RETURNED TO SERVICE.
WARNING
THIS UNIT MUST BE PROPERLY GROUNDED. [. . . ] Move the push button field wire from terminal 2 to the new terminal 2A. Connect the white wire from the operator side of the module to terminal 3 on the 10 pole terminal block. Connect the red wire from the operator side of the module to terminal 4 on the 10 pole terminal block. For additional wiring help refer to figure 2 below. Wire push button wires only to 1A, 2A, 3A and 4A. NOTE: For additional wiring help refer to figure 1.
WARNING
DO NOT CONNECT ANY OTHER TERMINALS IN THE OPERATOR TO TERMINALS 1A, 2A, 3A, OR 4A. ACCIDENTALLY CROSSING TERMINALS WILL DAMAGE THE LONG DISTANCE MODULE.
W
FIGURE 1
EXISTING CAUTION ORANGE WIRE NUT IN OPERATOR
T3
T4
T2
T1
T5
WH RD
BL GN BK
BK
TO OPERATOR
5. Connect one black wire from the operator side of the module to terminal 5 on the 10 pole terminal block.
BL
TO CONTROLS
GN
YE
OR
6. Connect the other black wire from the operator side of the module into the orange wire nut that is already in the operator. This wire nut has one orange, one purple, one yellow and at least 1 red wire nut. Connect the green wire from the operator side of the module to terminal 1 on the 10 pole terminal block. Connect the blue wire from the operator side of the module to terminal 2 on the 10 pole terminal block. 2
2A
1A
3A
4A
Open Close Stop
INSTALLATION INSTRUCTIONS (GATE OPERATORS W/ THREE BUTTON CONTROL STATION)
NOTE: Before you start modification, test all operator functions. COMPONENT MOUNTING Install the long distance control module to the side of the enclosure using the velcro located on the back of the module. Be sure that the placement of the module is central to the S3 board (for models SL540 and SL570 place module central to the terminal block located in the control box). Connect the orange wire from the controls side of the module to Stop (NC) on the control station with one of the orange wire nuts supplied. Connect the blue wire from the controls side of the module to Close (NO) on the control station with one of the orange wire nuts supplied.
WH RD BL GN BK BK
8. Connect the red wire from the operator side of the module to J1-3 on the S3 board (for Models SL540 and SL570 connect wire to T3 on the terminal block located in the control box). [. . . ] Cap off the orange and blue wires from the controls side of the module with two of the blue wire nuts supplied.
TO CONTROLS
J1-5
FIGURE 2
CONTROL INPUT 24 VAC
WH RD
BL GN
BK
BK
TO OPERATOR
2. Connect the yellow wire from the controls side of the module to (COM) on the accessory device with one of the orange wire nuts supplied. Connect the green wire from the controls side of the module to (NO) on the accessory device with one of the orange wire nuts supplied. Connect the black wires from the operator side of the module to 24VAC (may connect to R1 and R3 terminals in the operators). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 90 5024
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 90 5024 will begin.