User manual LIFT-MASTER CPS-04-01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER CPS-04-01. We hope that this LIFT-MASTER CPS-04-01 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER CPS-04-01.


Mode d'emploi LIFT-MASTER CPS-04-01
Download
Manual abstract: user guide LIFT-MASTER CPS-04-01

Detailed instructions for use are in the User's Guide.

[. . . ] Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens. The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary. The invisible light beam path must be unobstructed. [. . . ] The sensors are supplied with 36" long leads. We recommend the use of a liquid tight junction box near each sensor to make the connection to the sensor leads (Figure 4). Use rigid or flexible liquid tight conduit (depending on local codes) from junction boxes to operator. copper wire for connection between the sensors and the operator. WIRING CONNECTIONS: CPS-N4 - See page 3 CPS3-N4 - See page 4 CPS-LN4 - See page 5 Figure 4 Liquid Tight Conduit Liquid Tight Junction Box See Wiring Connections Sensor Beam 6" (15 cm) max. above floor Liquid Tight Junction Box Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor 2 W I R I N G F O R L I F T M A S T E R C O M M E R C I A L O P E R AT O R S CPS3-N4 Wiring Connections for use with Logic Operators (L2 or L3) Insert Logic Board into any available slot CPS3 Option Logic Board Logic 3 Board Shown Commercial Door Opener Protector System® Only 270K Resistor A B C D E F G H I J Brown Blue Commercial Door Opener Protector System® and 2-Wire Fail Safe Door Edge 2-Wire Edge JU1 R16 A B C D E F G H I J Brown Blue CPS3 protector and 2-wire fail-safe door edge connections For a 2-wire safety edge with an embedded resistor; 1. Remove the 270K resistor from the A & B terminals. Connect 2-wire coil cord or cord reel to the A & B terminals. For a 4-wire safety edge using a 2-wire coil cord; 1. Remove the 270K resistor from the A & B terminals. Add the resistor to 2 of the 4 wires at the safety edge, connect the coil cord to the other 2 safety edge wires (Figure 1). Connect the 2-wire coil cord or cord reel to the A & B terminals. NOTE: If the LiftMaster® photo eyes are not being connected you must remove the JU1 and R16 resistors from the CPS3CARD. Figure 1 Terminal A Terminal B 2-Wire s. e. Adding the Resistor 270K Resistor 3 Commercial Door Opener Protector System® and 4-Wire Fail Safe Door Edge 270K Resistor Brown Blue JU1 R16 A B C D E F G H I J Door Edge Contacts 4-Wire Edge NOTE: When using a 4-wire door edge only (without the LiftMaster® photo eyes), you must remove the JU1 and R16 resistors from the CPS3 card. Logic 3 Board will have the same connection. The maximum door edge resistance should be less than 1000 ohms as measured between any 4 conductors. This measurement should be taken when the door edge is in the closed contact state. Connection at CPS CPS-N4 Interface Box Operator/Auxiliary Point Connections Emitter Wire Receiver Wire Mechanical Terminal Logic 2 Terminal Logic 3 Terminal at CPS CPS-N4 at CPS CPS-N4 at Operator at Operator at Operator 3* 12 13 Wire Nut* 13 14 24V Common Sensor Black Sensor White Sensing Edge Sensing Edge or Brown or Blue Input (1/2) Input (2/2) Emitter Black Emitter White or Brown or Blue Receiver Black Receiver or Brown White or Blue 3* 8 8 10* 11 11 7 5 5 Diagram Reference Page OmniControl Surge HCT Terminal Suppressor Terminals OmniBoard Terminals Elite Gate OmniControl Application 1 Surge Suppressor Terminals Elite Gate Application 2 OmniControl Surge Suppressor Terminals 13 11 3 4 7 Sensor (1/2) Sensor (1/2) 7 13 11 13 11 3 TB3 1/3 See page 5 for inside vs outside photoeye 4 TB3 2/3 See page 5 for inside vs outside photoeye GL Board Terminal 9 or 10 See page 6 for inside vs outside photoeye 7 Estate Series with X3 or B3 Control Board at Operator TB7 1/2 Available TB7 2/2 Available 5 Operators with GL Control Board at Operator External Radio Terminal Strip R1 External Radio Terminal Strip R2 GL Board Terminal 5 6 *NOTES: Typical connections shown. On mechanical operators always refer to diagram that came with the operator. [. . . ] · Obstruct the light beam while the door is closing. The operator will not close if the indicator light in either sensor is not glowing steadily, alerting you to the fact that the sensor is misaligned or obstructed. NOTE: For non-solid state operators, if the door is stopped in a mid position, activation of the sensors will cause the door to open. This is similar to activating a sensor edge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CPS-04-01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER CPS-04-01 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag